Aim of the research is the study of improving the performance of the thermal station south Baghdad and the main reasons for reduced its efficiency. South Baghdad power planet comprises (6) steam turbine units and (18) gas turbine units .The gas turbine units are composed of two groups: the first group is made up of gas units (1,2), each of capacity (123) MW. The design efficiency of gas turbine units is 32%. The actual efficiency data of steam units is 18.3% instead of 45% which is the design efficiency. The main reason for efficiency reduction of gas units is the rejected thermal energy with the exhaust gases to atmosphere, that are (450-510) ℃.The bad type of fuel used (heavy) fuel. Another reason for the low efficiency and has a negative impact on the steam and gas units. The actual efficiency that is calculated to set the first group gas unit (1) is (27%). Suppose the steam is passed through the (HRSG) and this (HRSG) passes the combustion products emerging from first group gas turbine unit (1). The temperature of exhaust gases (Tieg =783k) entered (HRSG) and the temperature of gas out from the (HRSG) (Toeg =374k). The thermal efficiency of combined -cycle plant is (the amount of fuel that can be available by using the plant compound in combined cycle, is (3603.88) tons per year. The relationship between the account of load and compression ratio during the three seasons of the year as where a large difference in the degree of heat between summer and winter .When the high temperature in summer less than the energy generated. As was the rate of energy produced is (99.8, 90.6, 70.6) MW in the (winter, autumn and summer), respectively.
The study aims at finding out:
1. The students' attitude towards the mixed learning at the university.
2. The statistically significant differences in attitude towards the mixed learning at the university according to the specialization variable.
3. The statistically significant differences in attitude towards the mixed learning at the university according to the gender variable.
The researcher has constructed a scale for measuring the students' attitude towards the mixed learning at the university.
After assuring its validity and reliability, the scale has been given to a sample of (100) students. The sample is selected randomly from (4) colleges of the university of Baghdad, (2) for scientific specialization and (2)for h
The growing interest in the use of chaotic techniques for enabling secure communication in recent years has been motivated by the emergence of a number of wireless services which require the service provider to provide low bit error rates (BER) along with information security. This paper investigates the feasibility of using chaotic communications over Multiple-Input-Multiple-Output (MIMO) channels. While the use of Chaotic maps can enhance security, it is seen that the overall BER performance gets degraded when compared to conventional communication schemes. In order to overcome this limitation, we have proposed the use of a combination of Chaotic modulation and Alamouti Space Time Block Code. The performance of Chaos Shift Keying (CSK) wi
... Show MoreThe thermal performance of indirect expansion solar assisted heat pump, IX-SAHP, was investigated experimentally under Iraqi climate. An Indirect-Solar Assisted Heat Pump system was designed, built, instrumented and tested. Experimental tests were conducted by varying the controlling parameters to investigate their effects on the thermal performance of the IX-SAHP such as cooling water flow rate, heating water flow rate, ambient temperature and solar radiation intensity. The investigation covered values of cooling water flow rate of (2, 3, 4, 5 l/min) and heating water flow rate of (2, 3, 4, 5 l/min) under meteorological condition of Baghdad from November 2014 to January 2015.
The results indicated that the performance of the IX-
... Show Morestudy aimed to recognize the relationship shyness and depression and to recognize the differences between the genders, according to the variable of shyness and depression, the sample consisted (214) students, (141) female (73) male, and the sample responded scale of shyness and Inventory beck for depression, The Results of this study show that: the sample has a low degree shyness and a high degree depression, . There are no statistically significant differences according to gender variable in shyness, and there are statistically significant differences according to gender variable in depression favor for male, and there are statistically significant relationships between the variables of the study at lev
... Show MoreAbstract
This research aims to evaluate the application of the inspectors general of global indicators offices according to the axles (leadership, strategy and planning, employees, partners and resources, process management) and through the assumption main research which states that (there is an application for global indicators to evaluate performance in the offices of the ministries under study) which are subdivided into five sub-hypotheses according to the classification and division of the five axes of the checklist.
The researchers have taken refuge in the process of assessing the performance of the check list which included global i
... Show MoreThe current research illustrates experimentally the effect of series and parallel connection (Z-I Configurations) of flat plate water solar collectors array on the thermal performance of closed loop solar heating system. The study includes the effect of changing the water flow rate on the thermal efficiency. The results show that, the collector's efficiency in series connection is higher than the parallel connection within flow rate level less than (100) ℓ/hr. Moreover, the collector efficiency in parallel connection of (I-Configurations) is more than the (Z- Configurations) with increasing the water flow rate .The maximum daily efficiency for parallel (I-Configurations) and (Z- Configurations) are (55%) and (51%) at w
... Show MoreA design for a photovoltaic-thermal (PVT) assembly with a water-cooled heat sink was planned, constructed, and experimentally evaluated in the climatic conditions of the southern region of Iraq during the summertime. The water-cooled heat sink was applied to thermally manage the PV cells, in order to boost the electrical output of the PVT system. A set of temperature sensors was installed to monitor the water intake, exit, and cell temperatures. The climatic parameters including the wind velocity, atmospheric pressure, and solar irradiation were also monitored on a daily basis. The effects of solar irradiation on the average PV temperature, electrical power, and overall electrical-thermal efficiency were investigated. The findings i
... Show MoreThe aim of the research is to know the level of time management application and its impact on the performance of the job, a survey search in the general company for communication and information technology and provide recommendations that help employees to optimize the use of time and improve performance, which is an important element in controlling the various functions of the company. In order to achieve the objectives of the research, the questionnaire was based on two main variables and distributed to a random sample of (44) employees in the company out of (308) employees, thus the proportion of the sample (14%). After collecting the samples from the sample, there are (6) incomplete forms that have been retri
... Show MoreThe phenomenon of child labor, any activity performed by a child and represents a contribution to the production, this phenomenon had been rife in Iraqi society, after that the proportion of child labor for the age group (6-14 years) amounting to 3% in 2006, became for the same age group of 8% in 2008*.
It is recognized that each phenomenon reasons, the phenomenon which our atten
... Show MoreThermal performance of closed wet cooling tower has been investigated experimentally and theoretically
in this work. The theoretical model based on heat and mass transfer equations and heat and mass transfer balance equations which are established for steady state case. A new small indirect cooling tower was used for conducting experiments. The cooling capacity of cooling tower is 1 kW for an inlet water temperature of 38oC, a water mass velocity 2.3 kg/m2.s and an air wet bulb temperature of 26oC. This study investigates the relationship between saturation efficiency, cooling capacity and coefficient of performance of closed wet cooling tower versus different operating parameters such wet-bulb temperature, variable air-spray water fl