Aim of the research is the study of improving the performance of the thermal station south Baghdad and the main reasons for reduced its efficiency. South Baghdad power planet comprises (6) steam turbine units and (18) gas turbine units .The gas turbine units are composed of two groups: the first group is made up of gas units (1,2), each of capacity (123) MW. The design efficiency of gas turbine units is 32%. The actual efficiency data of steam units is 18.3% instead of 45% which is the design efficiency. The main reason for efficiency reduction of gas units is the rejected thermal energy with the exhaust gases to atmosphere, that are (450-510) ℃.The bad type of fuel used (heavy) fuel. Another reason for the low efficiency and has a negative impact on the steam and gas units. The actual efficiency that is calculated to set the first group gas unit (1) is (27%). Suppose the steam is passed through the (HRSG) and this (HRSG) passes the combustion products emerging from first group gas turbine unit (1). The temperature of exhaust gases (Tieg =783k) entered (HRSG) and the temperature of gas out from the (HRSG) (Toeg =374k). The thermal efficiency of combined -cycle plant is (the amount of fuel that can be available by using the plant compound in combined cycle, is (3603.88) tons per year. The relationship between the account of load and compression ratio during the three seasons of the year as where a large difference in the degree of heat between summer and winter .When the high temperature in summer less than the energy generated. As was the rate of energy produced is (99.8, 90.6, 70.6) MW in the (winter, autumn and summer), respectively.
Due to the potential cost saving and minimal temperature stratification, the energy storage based on phase-change materials (PCMs) can be a reliable approach for decoupling energy demand from immediate supply availability. However, due to their high heat resistance, these materials necessitate the introduction of enhancing additives, such as expanded surfaces and fins, to enable their deployment in more widespread thermal and energy storage applications. This study reports on how circular fins with staggered distribution and variable orientations can be employed for addressing the low thermal response rates in a PCM (Paraffin RT-35) triple-tube heat exchanger consisting of two heat-transfer fluids flow in opposites directions throug
... Show MoreLow-temperature stratification, high-volumetric storage capacity, and less-complicated material processing make phase-changing materials (PCMs) very suitable candidates for solar energy storage applications. However, their poor heat diffusivities and suboptimal containment designs severely limit their decent storage capabilities. In these systems, the arrangement of tubes conveying the heat transport fluid (HTF) plays a crucial role in heat communication between the PCM and HTF during phase transition. This study investigates a helical coil tube-and-shell thermal storage system integrated with a novel central return tube to enhance heat transfer effectiveness. Three-dimensional computational fluid dynamics simulations compare the proposed d
... Show MoreIn this paper, the effect of thermal radiation and magnetic field on the boundary layer flow and heat transfer of a viscous fluid due to an exponentially stretching sheet is proposed. The governing boundary layer equations are reduced to a system of ordinary differential equations. The homotopy analysis method (HAM) is employed to solve the velocity and temperature equations.
This research investigated the effectiveness of using different thickness values of polyimide (PI) interfacial layer in order to improve electrical and thermal properties of Al/ PI /c-Si capacitor. The PI spectra produced by poly(amic acid) (PAA) were characterized by using FT-IR analysis. After imidization of PAA, some absorption peaks vanished, whereas PI peaks appeared, due to the complete conversion of PAA to PI.
The results show that thermal decomposition resistance of polyimide films increases with the increase of polyimide thickness, because of the increase of the imide bond and the decrease of the average distance between amide groups.
Central banks around the world typically use various financial indicators to evaluate performance. In Iraq, the indicators used by central banks to evaluate the performance of banks are of great importance to ensure that the banks operating within the Iraqi banking system comply with the regulatory and legal requirements issued by the Central Bank of Iraq or the Ministry of Finance. Given the need to study the profitability indicator to ensure its ability to evaluate the performance of specialized banks in Iraq, these banks carry out their banking activities and businesses through capital funded by the government. The use of profitability indicators in evaluating the performance of specialized banks provides information about the profitabil
... Show MoreIn this research, the water quality of the potable water network in
Al-Shuala Baghdad city were evaluated and compare them with the
Iraqi standards (IQS) for drinking water and World Health
Organization standards (WHO), then water quality index (WQI) were
calculator: pH, heavy metals (lead, cadmium and iron), chlorides,
total hardness, turbidity, dissolved oxygen, total dissolved solid and
electrical conductivity. Water samples are collected weekly during
the period from February 2015 to April 2015 from ten sites. Results
show that the chlorides, total dissolved solid and electrical
conductivity less than acceptable limit of standards, but total
hardness and heavy metals in some samples higher than acceptabl
Experiment Factorial conducted with two factor in field texture silt clay loam soil, the first factor were Two Rotavator plow which different in number of rotary blades on flanges, weight, width, made and type, the second factor were four speeds tractor 2.62, 5.10, 7.55, 9.23 km/hr to compare performance two Rotavator under depth 12 cm and knowledge slippage, distance between beat blades, practical productivity, disturbed soil volume, percentage of the soil clods which have diameter less than 5 cm under complete block design with three replications using Least Significant Design 0.05. Results showed Galucho Rotavator recorder the higher practical productivity 0>7089 ha/hr, disturbed soil volume 809.8 m3/hr, percentage of the soil clods 96.1
... Show MoreThe objective of the research is to measure the impact of social responsibility on the financial performance of the National Bank of Iraq for the period from 2014 to 2016 (3 years) through discussing and analyzing the level of practice of the Bank of Baghdad for social responsibility and the impact on their financial performance during the period. To measure the independent variable (CSR), the researcher used the CSR Disclosure Index and relied on the ROA as an indicator to measure the dependent variable (financial performance). The results of the research showed the main hypothesis of the research, which states that the social responsibility of the banks has no significant impact on the financial performance. In relation to the disclosu
... Show MoreIn this research, the study of thermal treating by laser, plasma glow discharge and tubular furnace on Ti-6Al-4V alloy coated with hydroxyapatite by methods of dip coating and electrophoretic deposition .A group of samples was coated by dip coating and another group was coated by electrophoretic deposition. The first group was treated by pulse laser 10 (mJ) as energy for samples from both coating with uniform distributed pulses on every single sample surface, The second thermal treating was made by plasma glow discharge in a locally made system with argon atmosphere, 600 Volt , and 6 cm distance between the electrodes, The third treating was made by tubular furnace in air atmosphere and 400 °C for 1 hour duration. T
... Show MoreExperimental measurements of viscosity and thermal conductivity of single layer of graphene . based DI-water nanofluid are performed as a function of concentrations (0.1-1wt%) and temperatures between (5 to 35ºC). The result reveals that the thermal conductivity of GNPs nanofluids was increased with increasing the nanoparticle weight fraction concentration and temperature, while the maximum enhancement was about 22% for concentration of 1 wt.% at
35ºC. These experimental results were compared with some theoretical models and a good agreement between Nan’s model and the experimental results was observed. The viscosity of the graphene nanofluid displays Newtonian and Non-Newtonian behaviors with respect to nanoparticles concen