The design, construction and investigation of experimental study of two compound parabolic concentrators (CPCs) with tubular absorber have been presented. The performance of CPCs have been evaluated by using outdoor experimental measurements including the instantaneous thermal efficiency. The two CPCs are tested instantly by holding them on a common structure. Many tests are conducted in the present work by truncating one of them in three different levels. For each truncation the acceptance half angle (θc) was changed. Geometrically, the acceptance half angle for standard CPC is (26o). For the truncation levels for the other CPC 1, 2 and 3 the acceptance half angle were 20o, 26o and 59o, consequently. A significant difference between the instantaneous thermal efficiency of 3.86× CPC (θc=20o) and 2.32× CPC (θc=26o), and between that for 3.61× CPC (θc=26o) and 2.32× CPC (θc=26o). It's noticed that the difference between the instantaneous thermal efficiency of 2.32× CPC (θc=59o) and 2.32× CPC (θc=26o) is small compared with the difference of the first and second cases, the instantaneous thermal efficiency of 2.32× CPC (26o) was higher than those for other three CPCs. The experimental results show that the maximum thermal efficiency of the full 2.32×CPC (26o) is 0.708, the maximum thermal efficiency of the 3.93×CPC (15o), when it's truncated to 3.84× CPC (20o), 3.61× CPC (26o) and 2.32× CPC (59o) are 0.51, 0.52 and 0.66, respectively. As the concentration ratio decreases from (3.93× to 1×), the thermal efficiency, energy losses and optical efficiency increase from (0.47 to 63), (1.58 to 7.2 K.m2/W) and (0.494 to 0.797), respectively.
In this study, pebble bed as an absorber and storage material was placed in a south facing, flat plate air-type solar collector at fixed tilt angle of (45°). The effect of this material and differ- ent parameters on collector efficiency has been investigated experimentally and
theoretically. Two operation modes were employed to study the performance of the solar air heater. An inte- grated mode of continuous operation of the system during the period of (11:00 am – 3:00 pm) and non-integrated mode in which the system stored the solar energy through the day then used the stored energy during the period of (3:00 pm – 8:00 pm). The results of parametric study in case of continuous operating showed that the maximum average temperatur
The thermal performance of a flat-plate solar collector (FPSC) using novel heat transfer fluids of aqueous colloidal dispersions of covalently functionalized multi-walled carbon nanotubes with β-Alanine (Ala-MWCNTs) has been studied. Multi-walled carbon nanotubes (MWCNTs) with outside diameters of (< 8 nm) and (20–30 nm) having specific surface areas (SSAs) of (500 m2/g) and (110 m2/g), respectively, were utilized. For each Ala-MWCNTs, waterbased nanofluids were synthesized using weight concentrations of 0.025%, 0.05%, 0.075%, and 0.1%. A MATLAB code was built and a test rig was designed and developed. Heat flux intensities of 600, 800, and 1000 W/m2; mass flow rates of 0.6, 1.0, and 1.4 kg/min; and inlet fluid temperatures of 30, 40, an
... Show MoreAbstract
One of the most suitable materials to be used in latent heat thermal energy storage system (LHTES) are Phase change materials, but a problem of slow melting and solidification processes made many researchers focusing on how to improve their thermal properties. This experimental work concerned with the enhancing of thermal conductivity of phase change material. The enhancing method was by the addition of copper Lessing rings in phase change material (paraffin wax). The effect of diameter for the used rings was studied by using two different diameters (0.5 cm and 1cm). Also, three volumetric percentages of rings addition (3%, 6% and 10%) were tested for each diameter. The discharging process was done with
... Show MoreThis study has came as a result to discover on the references of the educational theories which leads the professors in the educational art departments in the Iraqi universities through knowing these ideological references indeed in an important slice of the society. This slice is: the members of professoriate. The study goal knows the ideological references to these theories for the professors in these departments.
In order to approve the research's goals. The researcher has selected a sample contains (50) professoriate members in these departments in the Iraqi universities which they have the educational art profession among the next scientific degrees (assistant teacher. teacher. assistant professor & professor).
The resea
In this paper, an experimental study of the thermal performance for hybrid solar air conditioning system was carried out, to investigate system suitability for the hot climate in Iraq. The system consists of vapor compression unit combined with evacuated tube solar collector and liquid storage tank. A three-way valve was installed after the compressor to control the direction flow of the refrigerant, either to the storage tank or directly to the condenser. The performance parameters were collected by data logger to display and record in the computer by using LabVIEW software. The results show that the average coefficient of performance of hybrid solar air conditioning system (R=1) was about 2.42 to 2.77 and the average p
... Show More
Mixed convection heat transfer to air inside an enclosure is investigated experimentally. The bottom wall of the enclosure is maintained at higher temperature than that of the top wall which keeps in oscillation motion, whereas the left and right walls are well insulated. The differential temperature of the bottom and top walls changed several times in order to accurately characterize the temperature distribution over a considerable range of Richardson number. Adjustable aspect ratio box was built as a test rig to determine the effects of Richardson number and aspect ratio on the flow behavior of the air inside the enclosure. The flow fields and the average Nusselt number profiles were presented in this wo
... Show MoreNumerical study has been conducted to investigate the thermal performance enhancement of flat plate solar water collector by integrating the solar collector with metal foam blocks.The flow is assumed to be steady, incompressible and two dimensional in an inclined channel. The channel is provided with eight foam blocks manufactured form copper. The Brinkman-Forchheimer extended Darcy model is utilized to simulate the flow in the porous medium and the Navier-Stokes equation in the fluid region. The energy equation is used with local thermal equilibrium (LTE) assumption to simulate the thermofield inside the porous medium. The current investigation covers a range of solar radiation intensity at 09:00 AM, 12:00 PM, and 04:00
... Show MoreThe experiment was conducted in field of the University of Baghdad, Jadryia region, Baghdad to measure vibration and performance efficiency of grass mower (machine cutting grass). Vibration in three axes are longitudinal X , lateral Y and vertical Z in four places of mower machine during cutting grass and Practical Productivity, Efficiency and Fuel Consumption measured in this experiment . Factorial design (3 x 2) used, mower speeds included 1.9 3.6 and 6.4 km/hr and engine load included idling and full load according to randomized complete design were used in this experiment. Least Significant Design (LSD) 0.05 was used to compare the mean of treatment. Result were showed that the mower speed 6.4 km/hr recorded high productivity (0.6557 ha
... Show MoreIn the present work, experimental tests was done to explain the effect of insulation and water level on the yield output. Linear basin, single slope solar still used to do this purpose. The test was done from May to August 2017 in Mosul City-Iraq (Latitude: Longitude: Elevation: 200 m, and South-East face). Experimental results showed that the yield output of the still increased by 20.785% and 19.864% in case of using thermal insulation at 4cm and 5cm respectively, also the yield output decrease by 15.134% as the water level increase from 4 to 5cm, with the presence of insulation and 14.147% without it. It has been conclude that the insulation and water level play important role in the process of passive