Preferred Language
Articles
/
alkej-222
Study on Flow Characteristics and Heat Transfer Behavior Around Different Geometrical Corrugated Extended Surfaces
...Show More Authors

Abstract

The current study presents numerical investigation of the fluid (air) flow characteristics and convection heat transfer around different corrugated surfaces geometry in the low Reynolds number region (Re<1000). The geometries are included wavy, triangle, and rectangular. The effect of different geometry parameters such as aspect ratio and number of cycles per unit length on flow field characteristics and heat transfer was estimated and compared with each other. The computerized fluid dynamics package (ANSYS 14) is used to simulate the flow field and heat transfer, solve the governing equations, and extract the results. It is found that the turbulence intensity for rectangular extended surface was larger than that of triangle and wavy extended surfaces at the same aspect ratio and number of cycles per unit length. Also, the increasing of turbulence intensity leads to enhance the heat transfer coefficient and consequently the amount of heat transfer. According to previous results, if the pressure head losses along the upstream are not important, the using of rectangular extended surface is better than the triangle which is also better than wavy extended surface.

Keywords: Flow Characteristics, Heat Transfer, Corrugated Surfaces, Numerical Analysis by ANSYS.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Thu Dec 29 2016
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Study of Different of Surface Characteristics Between Gram Negative and Positive Bacteria
...Show More Authors

         The study included evaluation of cell surface charge and hydrophobicity of Escherichia coli, Klebsilla aerogenes, Proteus spp, Bacillus cereus, Staphylococcus epidermidis, Staphylococcus aureus(1) and Staphylococcus aureus(2) were determined by hydrocarbon adherence and hydrophobic interaction chromatography. The results showed that the negative charge of cell surface of gram negative bacteria was much higher than on gram positive once when these bacteria were grown on nutrient agar at 37 c for 18 h . E.coli was more negative charged than Klebsilla aerogenes and Proteus spp. The hydrophobicity of gram positive bacteria was much

... Show More
View Publication Preview PDF
Publication Date
Wed Oct 24 2018
Journal Name
Chalcogenide Letters
STUDY OF GEOMETRICAL AND ELECTRONIC PROPERTIES OF ZnS WURTZOIDS VIA DFT
...Show More Authors

Publication Date
Sun Sep 01 2013
Journal Name
Journal Of Economics And Administrative Sciences
Characteristics and pattern of organizational structure for general inspectors offices :Testing Research
...Show More Authors


    
Concentrated research topic in addressing variable vital to the work of offices of inspectors general, construction and scale effectiveness and efficiency is the organizational structure, which are important as is obvious to any researcher in the management and organization and this variable would affect the exercise task supervision and inspection of financial and administrative corruption and combat efficiently, Thus this effect will be placed in the fold ability to achieve goals. That the creation of the organizational structure and requirements to achieve harmony between its properties is creating step towards success. This research aims to analyze the characteristics and style o

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Nov 01 2019
Journal Name
Journal Of Engineering
Assessment the Engineering Characteristics of the Smear Zone around PVDs Using Laboratory Tests
...Show More Authors

Smear zone is usually formed around the prefabricated vertical drains (PVD’s) due to mandrel driving. The geotechnical properties of the soil in this zone exhibit significant changes that affect the performance of the PVD’s. The most relevant property in this respect is the coefficient of permeability. So far, no serious attention is paid to investigate the effects of shearing under large shear strains on the geotechnical properties of the soft soil in Fao region. In this study, an extensive laboratory testing program was conducted to assess the characteristics of the smear zone with an emphasis on the permeability coefficient of Fao soft soil. The results show that the permeability of the smear zone is about 70% of

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Jul 01 2021
Journal Name
Journal Of Mechanical Engineering Research And Developments
Numerical Investigation of Natural Convection Heat Transfer in Partially Filled Porous Enclosure Subjected to Constant Heat
...Show More Authors

Steady natural convection in a square enclosure with wall length (L= 20 cm) partially filled by saturated porous medium with same fluid (lower layer) and air (upper layer) is investigated. The conceptual study of the achievements of the heat transfer is performed under effects of bottom heating by constant heat flux (q=150,300,450,600W/m2 ) for three heaters size (0.2,0.14,0.07)m with symmetrically cooling with constant temperature on two vertical walls and adiabatic top wall. The relevant filled studied parameters are four different porous medium heights (Hp=0.25L,0.5L, 0.75L, L), Darcey number (Da1) 3.025×10-8 and (Da2) 8.852×10-4 ) and Rayleigh number range (60.354 - 241.41), (1.304×106 – 5.2166×106 ) for Da1 and Da2 cases respecti

... Show More
Preview PDF
Publication Date
Fri Jul 21 2023
Journal Name
Journal Of Engineering
Experimental Study of Natural Convection Heat Transfer in Confined Porous Media Heated From Side
...Show More Authors

Transient three-dimensional natural convection heat transfer due to the influences of heating from one side of an enclosure filled with a saturated porous media, whereas the opposite side is maintained at a constant cold temperature, and the other four sides are adiabatic, were investigated in the present work experimentally. Silica sand was used as a porous media saturated with distilled water filled in a cubic enclosure heated from the side,using six electrical controlled heaters, at constant temperatures of (60, 70, 80, 90, and 100oC). The inverse side cooled at a constant temperature of (24oC) using an aluminum heat exchanger, consisted of 15 channels feeded with constant temperature water. Eighty thermocouples were used to control t

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Sep 30 2009
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Prediction of Effective Bed Thermal Conductivity and Heat Transfer Coefficient in Fluidized Beds
...Show More Authors

Experimental study of heat transfer coefficients in air-liquid-solid fluidized beds were carried out by measuring the heat rate and the overall temperature differences across the heater at different operating conditions. The experiments were carried out in Q.V.F. glass column of 0.22 m inside diameter and 2.25 m height with an axially mounted cylindrical heater of 0.0367 m diameter and 0.5 m height. The fluidizing media were water as a continuous phase and air as a dispersed phase. Low density (Ploymethyl-methacrylate, 3.17 mm size) and high density (Glass beads, 2.31 mm size) particles were used as solid phase. The bed temperature profiles were measured axially and radially in the bed for different positions. Thermocouples were connecte

... Show More
View Publication Preview PDF
Publication Date
Fri Jan 01 2021
Journal Name
International Journal Of Thermal Sciences
Experimental and numerical investigations of heat transfer enhancement in shell and helically microtube heat exchanger using nanofluids
...Show More Authors

View Publication
Scopus (43)
Crossref (41)
Scopus Clarivate Crossref
Publication Date
Wed Oct 05 2016
Journal Name
Al-academy
The Characteristics of Art forms in the Byzantine icons painting
...Show More Authors

The problem with research in the question of whether art forms in the religious icon Byzantine, heiress docility and tradition craftsman arts civilizations of the above? ... And if you are well, you helped a quotation on the entry of strange ideas rampant within religious traditions, and are prompted to do Movement rejected prohibition, and the outbreak of the icons war? ... Or is it, in fact - and as researcher finds - the result of a need communication between the religious and the recipient organization in the establishment of a deliberative speech, be visible, along with reading it and audible? .. And lies the importance of this study is being added technical knowledge of the library that will enrich researchers and scholars in this

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Jan 30 2020
Journal Name
Journal Of Engineering
Study Impact of Unified Power Flow Controller (UPFC) on a Transmission Line Performance under Different Loading Conditions
...Show More Authors

Now-a-days the Flexible AC Transmission Systems (FACTS) technology is very effective in improving the power flow along the transmission lines and makes the power system more flexible and controllable. This paper deals with the most robust type of FACTS devices; it’s a Unified Power Flow Controller (UPFC). Many cases have been taken to study how the system behaves in the presence and absence of the UPFC under normal and contingency conditions. The UPFC is a device that can be used to improve the bus voltage, increasing the loadability of the line and reduce the active and reactive power losses in the transmission lines, through controlling the flow of real and reactive power. Both the magnitude and the phase angle of th

... Show More
View Publication Preview PDF
Crossref (1)
Crossref