Preferred Language
Articles
/
alkej-202
Experimental Modeling and Optimization of Fatigue Life and Hardness of Carbon Steel CK35 under Dynamic Buckling
...Show More Authors

Abstract

 

The aim of this paper is to model and optimize the fatigue life and hardness of medium carbon steel CK35 subjected to dynamic buckling. Different ranges of shot peening time (STP) and critical points of slenderness ratio which is between the long and intermediate columns, as input factors, were used to obtain their influences on the fatigue life and hardness, as main responses. Experimental measurements of shot peening time and buckling were taken and analyzed using (DESIGN EXPERT 8) experimental design software which was used for modeling and optimization purposes. Mathematical models of responses were obtained and analyzed by ANOVA variance to verify the adequacy of the models. The resultant quadratic models were obtained. A good agreement was found between the results of these models and optimization with the experimental ones with confidence level of 95 %.

 

View Publication Preview PDF
Quick Preview PDF
Publication Date
Mon Dec 30 2019
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Experimental Study of Iraqi Light Naphtha Isomerization over Ni-Pt/H-Mordenite
...Show More Authors

Hydroisomerization of Iraqi light naphtha was studied on prepared Ni-Pt/H-mordenite catalyst at a temperature range of 220-300°C, hydrogen to hydrocarbon molar ratio of 3.7, liquid hourly space velocity (LHSV) 1 hr-1 and at atmospheric pressure.

The result shows that the hydrisomerization of light naphtha increases with the increase in reaction temperature at constant LHSV. However, above 270 0C the isomers formation decreases and the reaction is shifted towards the hydrocracking reaction, a higher octane number of naphtha was formed at 270 °C.

View Publication Preview PDF
Crossref (5)
Crossref
Publication Date
Sat Mar 31 2018
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Experimental Study for the Influence of Operating Parameters on Copper Electrorefining Process
...Show More Authors

Copper electrodeposition by electrorefining process in acidic sulfate media contains 40 g/l of cupric ions and 160 g/l of sulfuric acid was achieved to study the influence of the operating parameters on cathode purity, surface morphology, deposition rate, current efficiency and power consumption. These operating parameters and there ranges are: current density 200, 300 and 400 A/m2, electrolyte temperature 35, 50 and 65 oC, electrodes spacing 15, 30 and 45 mm and electrolyte residence time 6, 4 and 2 h were utilized. XRF, SEM and EDX analyses were attained to clarify the properties of the produced cathode.

View Publication Preview PDF
Publication Date
Sat Dec 31 2016
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Experimental Investigation of Mass Transfer for Copper Reduction by Weight Difference Technique
...Show More Authors

An experimental analysis was included to study and investigate the mass transport behavior of cupric ions reduction as the main reaction in the presence of 0.5M H2SO4 by weight difference technique (WDT). The experiments were carried out by electrochemical cell with a rotating cylinder electrode as cathode. The impacts of different operating conditions on mass transfer coefficient were analyzed such as rotation speeds 100-500 rpm, electrolyte temperatures 30-60 , and cupric ions concentration 250-750 ppm. The order of copper reduction reaction was investigated and it shows a first order reaction behavior. The mass transfer coefficient for the described system was correlated with the aid of dimensionless groups as fo

... Show More
View Publication Preview PDF
Publication Date
Sat Jun 01 2019
Journal Name
Prensa Medica Argentina
The effect of niclosamide in acetic-acid induce colitis: An experimental study
...Show More Authors

Scopus (28)
Scopus
Publication Date
Tue May 16 2023
Journal Name
Journal Of Engineering
EXPERIMENTAL INVESTIGATION OF INDIVIDUAL EVACUATED TUBE HEAT PIPE SOLAR WATER HEATING SYSTEMS
...Show More Authors

lar water heating systems with heat pipes of three diameter groups of 16, 22 and 28.5 mm. The first and third groups had evaporator lengths of 1150, 1300 and 1550 mm. The second group had an additional length of 1800 mm. all heat pipes were of fixed condenser length of 200 mm. Ethanol at 50% fill charge ratio of the evaporator volume was used as the heat pipes working fluid. Each heat pipe condenser section was inserted in a storage tank and the evaporator section inserted into an evacuated glass tube of the Owens- Illinois type. The combined heat pipe and evacuated glass tube form an active solar collector of a unique design.
The resulting ten solar water heating systems were tested outdoors under the meteorological conditions of Bag

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Mon May 20 2019
Journal Name
The Journal Of Engineering
Experimental comparison of two linear machines developed for the free piston engine
...Show More Authors

: In this study, a linear synchronous machine is compared with a linear transverse flux machine. Both machines have been designed and built with the intention of being used as the power take off in a free piston engine. As both topologies are cylindrical, it is not possible to construct either using just flat laminations and so alternative methods are described and demonstrated. Despite the difference in topology and specification, the machines are compared on a common base in terms of rated force and suitability for use as a generator. Experience gained during the manufacture of two prototypes is described.

View Publication Preview PDF
Crossref (9)
Clarivate Crossref
Publication Date
Sat Sep 02 2017
Journal Name
International Journal Of Science And Research (ijsr)
Experimental Investigation on Rheological Characterization of ecovio® F Film C2203biopolymer Melts
...Show More Authors

Publication Date
Mon Dec 31 2012
Journal Name
Al-khwarizmi Engineering Journal
Experimental Study on the Impact of External Geometrical Shape on Free and Forced Convection Time Dependent Average Heat Transfer Coefficient during Cooling Process
...Show More Authors

In this research, an experimental study was conducted to high light the impact of the exterior shape of a cylindrical body on the forced and free convection heat transfer coefficients when the body is hold in the entrance of an air duct. The impact of changing the body location within the air duct and the air speed are also demonstrated. The cylinders were manufactured with circular, triangular and square sections of copper for its high thermal conductivity with appropriate dimensions, while maintaining the surface area of all shapes to be the same. Each cylinder was heated to a certain temperature and put inside the duct at certain locations. The temperature of the cylinder was then monitored. The heat transfer coefficient were then cal

... Show More
View Publication Preview PDF
Publication Date
Fri Apr 12 2019
Journal Name
Journal Of Economics And Administrative Sciences
The Compatibility between leadership of empowerment and organizational learning abilities and their reflection on knowledge capital Applied research at Wasit University
...Show More Authors

The current research aims at: - Identifying the role played by the leadership in empowerment and organizational learning abilities and their reflection on the knowledge capital, and the extent to which these concepts can be applied effectively at Wasit University. The problem of research .... In a series of questions: The most important is that the dimensions leadership empowerment and distance learning organizational capacity correlation relationship and impact and significant statistical significance with the capital knowledge.

     To understand the nature of the relationship and the impact between the variables, leadership was adopted by empowerment as the fir

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Dec 01 2017
Journal Name
Journal Of Accounting And Financial Studies ( Jafs )
Determining the Optimal Ratio of Liquidity in Iraqi Commercial Banks for period (2005-2013): applied research using Iraqi Commercial Banks as a sample study
...Show More Authors

  This study  focused on a fundamental issue which was represented by ability of Iraqi central bank in facing the difficulty of determining  the optimal ratio of liquidity in the Iraqi banks in terms of the balancing between its obligations to the depositors and borrowers, and liquidate their funds on one hand and the risks on the other hand.the search aimed  for achieving the goals which represented by identifying the possibility of Iraqi banks to apply the regulations rules and  instructions  issued by central bank  of  Iraq in determining  ratio  of  liquidity and  its  appropriate with Iraqi  banks  action to implement  a  reasonable  profit to&

... Show More
View Publication
Crossref (1)
Crossref