Theoretical and Practical Investigation of Blood Flow through Stenosed Coronary Lad Artery
...Show More Authors

Atherosclerosis is the most common causes of vascular diseases and it is associated with a restriction in the lumen of blood vessels. So; the study of blood flow in arteries is very important to understand the relation between hemodynamic characteristics of blood flow and the occurrence of atherosclerosis.

looking for the physical factors and correlations that explain the phenomena of existence the atherosclerosis disease in the proximal site of LAD artery in some people rather than others is achieved in this study by analysis data from coronary angiography as well as estimating the blood velocity from coronary angiography scans without having a required data on velocity by using some mathematical equations and physical laws. Fifty-eight patients were included in this study that underwent cardiac catheterization for diagnostic coronary angiography. It found some information that may explain the ability of small arteries to develop the lesions with time mainly in proximal site of LAD artery.

For investigation the fluid-structural response to pulsatile Newtonian and non-Newtonian blood flow through an axisymmetric stenosed coronary artery; the theoretical simulation is built up by using ANSYS 11, to evaluate the biomechanical parameters in the atherosclerotic process. Rigid and Newtonian cases were investigated to provide an understanding on the effects of incorporating the Fluid-Structural Interaction (FSI) into the model. For validation of the models and methods used, the computation results are compared with the previous studies. The non-Newtonian Carreau model was investigated with FSI, which showed a little difference in comparison with the Newtonian flow model in terms of velocity, pressure, wall shear stress (WSS), and stress distribution.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Mon Feb 01 2016
Journal Name
Journal Of Engineering
Impact of Different H/D Ratio on Axial Gas Holdup Measured by Four-Tips Optical Fiber Probe in Slurry Bubble Column
...Show More Authors

In wide range of chemical, petrochemical and energy processes, it is not possible to manage without slurry bubble column reactors. In this investigation, time average local gas holdup was recorded for three different height to diameter (H/D) ratios 3, 4 and 5 in 18" diameter slurry bubble column. Air-water-glass beads system was used with superficial velocity up to 0.24 m/s. the gas holdup was measured using 4-tips optical fiber probe technique. The results show that the axial gas holdup increases almost linearly with the superficial gas velocity in 0.08 m/s and levels off with a further increase of velocity. A comparison of the present data with those reported for other slurry bubble column having diameters larger than

... Show More
View Publication Preview PDF
Publication Date
Mon Jul 31 2017
Journal Name
Journal Of Engineering
Development of an On-Line Self-Tuning FPGA-PID-PWM Control Algorithm Design for DC-DC Buck Converter in Mobile Applications
...Show More Authors

View Publication Preview PDF
Publication Date
Sat Jul 11 2026
Journal Name
Journal Of Physical Education
The Effect of Increasing Rehabilitation Program Using Electric Stimulation On Rehabilitating Knee Joint Working Muscles Due to ACL Tear In Athletes
...Show More Authors

View Publication
Publication Date
Sat Sep 30 2023
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Effect of Heterogeneity on Recovery Factor for Carbonate Reservoirs. A Case Study for Mishrif Formation in West Qurna Oilfield, Southern Iraq
...Show More Authors

Oil recovery could be impacted by the relation between vertical permeability (Kv) and horizontal permeability (Kh) (Kv/Kh). 4816 plugs that have been getting hold of 18 wells of Mishrif formation in the West Qurna oilfield were used. Kv/Kh data provided some scatter, but the mean is ~1. Kv/Kh =1 was used for the Petrel model before upscaling according to the heterogeneity of each layer.

Kv/Kh values for Mishrif Formation in West Qurna Oilfield are 0.8 for relatively homogeneous, 0.4 for heterogeneous rock, and 0.1 for cap rocks (CRII).

   Eclipse TM was used for reservoir simulation. PVT and SCAL data e

... Show More
View Publication Preview PDF
Crossref (16)
Crossref
Publication Date
Wed Aug 30 2023
Journal Name
Al-kindy College Medical Journal
The indexing of the Al-Kindy College Medical Journal in the Scopus Database Journals: A Fundamental Step toward an International Recognition
...Show More Authors

On Saturday, May 13, 2023, a glorious day was engraved in the history of Al-Kindy College Medical Journal as it is the day of indexing the journal in the Scopus Database Journals. The journal has paced a strenuous journey to make that achievement.

View Publication Preview PDF
Scopus (1)
Scopus Crossref
Publication Date
Fri Jan 13 2023
Journal Name
World Academy Of Sciences Journal
Potential effects of miR‑146 expression in relation to malondialdehyde as a biomarker for oxidative damage in patients with breast cancer
...Show More Authors

View Publication
Scopus (16)
Crossref (6)
Scopus Crossref
Publication Date
Tue Oct 04 2022
Journal Name
Cureus
The Impact of Angiotensin Converting Enzyme-2 (ACE-2) on Bone Remodeling Marker Osteoprotegerin (OPG) in Post-COVID-19 Iraqi Patients
...Show More Authors

View Publication Preview PDF
Crossref (8)
Clarivate Crossref
Publication Date
Thu Oct 01 2020
Journal Name
Journal Of Engineering
Chemical-Free Greywater Treatment Using Aeration, Sedimentation, Followed by Granular Activated Carbon Filter (GAC) -A Case Study of Baghdad city household
...Show More Authors

Greywater is a possible water source that can be improved for meeting the quality required for irrigation. Treatment of greywater can range from uncomplicated coarse filtration to advanced biological treatment. This article presents a simple design of a small scale greywater treatment plant, which is a series of physical and natural processes including screening, aeration, sedimentation, and filtration using granular activated carbon filter and differentiates its performance with sand filter. The performance of these units with the dual filter media of (activated carbon with sand) in treatment of greywater from Iraqi house in Baghdad city during 2019 and that collected from several points including washbasins, kitchen si

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Mon Mar 27 2023
Journal Name
8th Engineering And 2nd International Conference For College Of Engineering – University Of Baghdad: Coec8-2021 Proceedings
Experimental study of natural convection heat transfer on an enclosure partially filled porous medium heated from below by constant heat flux
...Show More Authors

This study reports on natural convection heat transfer in a square enclosure of length (L=20 cm) with a saturated porous medium (solid glass beads) having same fluid (air) at lower horizontal layer and free air fill in the rest of the cavity's space. The experimental work has been performed under the effects of heating from bottom by constant heat flux q=150,300,450,600 W/m2 for four porous layers thickness Hp (2.5,5,7.5,1) cm and three heaters length δ(20,14,7) cm. The top enclosure wall was good insulated and the two side walls were symmetrically cooled at constant temperature. Four layers of porous media with small porosity, Rayleigh number range (60.354 - 241.41) and (Da) 3.025x10-8 has been investigated. The obtained data of temperatu

... Show More
View Publication
Scopus (6)
Crossref (5)
Scopus Crossref
Publication Date
Mon Oct 02 2023
Journal Name
Journal Of Engineering
Controlling the Unbalanced Voltages of a Series-Connected Lead-Acid Batteries in a PV Power Storage System using Dynamic Capacitor Technique
...Show More Authors

Lead-acid batteries have been used increasingly in recent years in solar power systems, especially in homes and small businesses, due to their cheapness and advanced development in manufacturing them. However, these batteries have low voltages and low capacities, to increase voltage and capacities, they need to be connected in series and parallel. Whether they are connected in series or parallel, their voltages and capacities must be equal otherwise the quality of service will be degraded. The fact that these different voltages are inherent in their manufacturing, but these unbalanced voltages can be controlled. Using a switched capacitor is a method that was used in many methods for balancing voltages, but their respons

... Show More
View Publication Preview PDF
Scopus (2)
Scopus Crossref