Preferred Language
Articles
/
alkej-170
Estimation of SNR Including Quantization Error of Multi-Wavelength Lidar Receiver
...Show More Authors

 This paper comprises the design and operation of mono-static backscatter lidar station based on a pulsed Nd: YAG laser that operates at multiple wavelengths. The three-color lidar laser transmitter is based on the collinear fundamental 1064 nm, second harmonic 532 nm and a third harmonic 355nm output of a Nd:YAG laser. The most important parameter of lidar especially daytime operations is the signal-to-noise ratio (SNR) which gives some instructions in designing of lidar and it is often limit the effective range. The reason is that noises or interferences always badly affect the measured results. The inversion algorithms have been developed for the study of atmospheric aerosols. Signal-to-noise ratio (SNR) of three-color channel receivers were presented while averaging together 1, 20, 50 and 100 lidar returns and combined to the signal to noise ratio associated with the quantization process for each channel.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Fri Dec 01 2023
Journal Name
Baghdad Science Journal
A novelty Multi-Step Associated with Laplace Transform Semi Analytic Technique for Solving Generalized Non-linear Differential Equations
...Show More Authors

 

   In this work, a novel technique to obtain an accurate solutions to nonlinear form by multi-step combination with Laplace-variational approach (MSLVIM) is introduced. Compared with the  traditional approach for variational it overcome all difficulties and enable to provide us more an accurate solutions with extended of the convergence region as well as covering to larger intervals which providing us a continuous representation of approximate analytic solution and it give more better information of the solution over the whole time interval. This technique is more easier for obtaining the general Lagrange multiplier with reduces the time and calculations. It converges rapidly to exact formula with simply computable terms wit

... Show More
View Publication Preview PDF
Scopus (1)
Scopus Crossref
Publication Date
Wed Jun 01 2005
Journal Name
Journal Of The College Of Languages (jcl)
המאבק הפנימי של מרדכי זאב פיארברג מתוך גיבורו של הסיפור "לאן?" מורה עוזר זינה אייד קסים
...Show More Authors

המחקר הזה עוסק באחד מהסופרים העבריים שנחשבו בעלי־השפעה בתהליך הספרות
העברית החדשה על אף גילו הקצר ועל אף שהוא השאיר עזבון ספרותי מועט , אך עם זה דמותו עולה
לענינו גם מתוך כתביו המעטים כאילו הם טבועים בחותם, הסופר הזה הוא מרדכי זאב פיארברג.
במחקר זה טיפלנו בחייו של המספר הזה בקיצור וגם ביצירותיו באופן כללי, ובסימנים המאפינים
את גיבוריו, ובמיוחד גיבורו של הסיפור "לאן?" שהוא אכן גיבור פיארברגי מובהק והוא נת

... Show More
View Publication Preview PDF
Publication Date
Sat Jan 02 2021
Journal Name
Journal Of The College Of Languages (jcl)
Translating Food and Drink-Related Insults in Shakespeare’s (Henry IV) into Arabic
...Show More Authors

        This study highlights the problems of translating Shakespeare's food and drink-related insults (henceforth FDRIs) in (Henry IV, Parts I&II) into Arabic. It adopts (Vinay & Darbelnet's:1950s) model, namely (Direct& Oblique) to highlight the applicability of the different methods and procedures made by the two selected translators (Mashati:1990 & Habeeb:1905) .The present study tries to answer the following questions:(i) To what extent the FDRIs in Henry IV might pose a translational problem for the selected translators to find suitable cultural equivalents for them? (ii) Why do the translators, in many cases, resort to a literal procedure which is almost not worka

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Jan 01 2017
Journal Name
Journal Of The College Of Languages (jcl)
Traducción de los dos verbos auxiliares ser y estar del español al árabe en la frase nominal
...Show More Authors

Resumen:

       La traducción de los dos verbos ser y estar no es una tarea tan simple como piensan muchas personas, sino es una de las complicadas y difíciles tareas, ya que el traductor tiene que saber y perfeccionar los correctos casos gramaticales relacionados con esos dos verbos auxiliares  tanto el verbo ser como el verbo estar, especialmente en la frase nominal para que pueda dar una clara y correcta traducción. Usados con el mismo adjetivo, "ser" comunicará una cualidad que es parte de la identidad o naturaleza del sujeto, mientras que "estar" comunicará un estado o circunstancia del mismo. Este e

... Show More
View Publication Preview PDF
Publication Date
Thu Dec 01 2022
Journal Name
Al-khwarizmi Engineering Journal
BCI-Based Smart Room Control using EEG Signals
...Show More Authors

In this paper, we implement and examine a Simulink model with electroencephalography (EEG) to control many actuators based on brain waves. This will be in great demand since it will be useful for certain individuals who are unable to access some control units that need direct contact with humans. In the beginning, ten volunteers of a wide range of (20-66) participated in this study, and the statistical measurements were first calculated for all eight channels. Then the number of channels was reduced by half according to the activation of brain regions within the utilized protocol and the processing time also decreased. Consequently, four of the participants (three males and one female) were chosen to examine the Simulink model during di

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Dec 18 2017
Journal Name
Al-khwarizmi Engineering Journal
High Order Sliding Mode Observer-Based Output Feedback Controller Design For Electro-Hydraulic System
...Show More Authors

A perturbed linear system with property of strong observability ensures that there is a sliding mode observer to estimate the unknown form inputs together with states estimation. In the case of the electro-hydraulic system with piston position measured output, the above property is not met. In this paper, the output and its derivatives estimation were used to build a dynamic structure that satisfy the condition of strongly observable. A high order sliding mode observer (HOSMO) was used to estimate both the resulting unknown perturbation term and the output derivatives. Thereafter with one signal from the whole system (piton position), the piston position make tracking to desire one with a simple linear output feedback controller after ca

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat Apr 01 2017
Journal Name
Journal Of Economics And Administrative Sciences
Use aggregate slide estimate additive splines estimation for the diagnosis of non-linear composite model self-regression with practical application
...Show More Authors

Nonlinear time series analysis is one of the most complex problems ; especially the nonlinear autoregressive with exogenous variable (NARX) .Then ; the problem of model identification and the correct orders determination considered the most important problem in the analysis of time series . In this paper , we proposed splines  estimation method for model identification , then we used three criterions for the correct orders determination. Where ; proposed method used to estimate the additive splines for model identification , And the rank determination depends on the additive property  to avoid the problem of curse dimensionally . The proposed method is one of the nonparametric methods , and the simulation results give a

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Sep 11 2018
Journal Name
Iraqi Journal Of Physics
Estimation the annual dose for residents in the area around the berms of Al-Tuwaitha nuclear site using RESRAD software
...Show More Authors

RESRAD is a computer model designed to estimate risks and radiation doses from residual radioactive materials in soil. Thirty seven soil samples were collected from the area around the berms of Al-Tuwaitha site and two samples as background taken from an area about 3 km north of the site. The samples were measured by gamma-ray spectrometry system using high purity germanium (HPGe) detector. The results of samples measurements showed that three contaminated area with 238U and 235U found in the study area. Two scenarios were applied for each contaminated area to estimate the dose using RESRAD (onsite) version 7.0 code. The total dose of resident farmer scenario for area A, B and C are 0.854, 0.033 and 2.15×10-3 mSv.yr-1, respectively. Whi

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Mar 30 2023
Journal Name
Iraqi Journal Of Science
Serum-Glutamic-Pyruvic-Transaminase (SGPT) and Serum- Glutamic-Oxaloacetic-Transaminase (SGOT) Estimation in Different Groups of Women Infected with Toxoplasmosis
...Show More Authors

The aim of this study was to investigate the disturbances of some liver enzymes like GPT and GOT level in different groups of women infected with toxoplasmosis. This study was performed on 600 apparently healthy women (pregnant, miscarriage and single) collected from different hospitals in Baghdad, AL-Yarmouk Teaching Hospital and Fatima AL-Zahra Hospital for Obstetric and children and Hay Hiteen clinic during November 2013 till April 2014. The detection of toxoplasmosis was done by a preliminary screening test LAT and the positive percentage was (29.55%), (30.36%) and (40.08%) for pregnant, miscarriage and single women respectively. While, the confirmation of positive results of LAT was done by ELISA-IgG and the results were (40%), (41.

... Show More
View Publication Preview PDF
Publication Date
Mon Aug 05 2024
Journal Name
Pharmacia
A validated spectrophotometric analysis for simultaneous estimation of vincristine sulfate and bovine serum albumin in pure preparations using Vierordt’s method
...Show More Authors

The novel Vierordt’s approach, or simultaneous equation method, was created and validated for the concurrent determination of vincristine sulfate (VCS) and bovine serum albumin (BSA) in pure solutions utilizing UV spectrophotometry. It is simple, precise, economical, rapid, reliable, and accurate. This method depends on measuring absorbance at two wavelengths, 296 nm and 278 nm, which correspond to the λmax of VCS and BSA in deionized water, respectively. The calibration curves of VCS and BSA are linear at concentration ranges of 10–60 μg/mL and 200–1600 μg/mL, with correlation coefficient values (R2) of 1 and 0.999, respectively. The limits of detection (LOD) and quantification (LO

... Show More
View Publication
Scopus Clarivate Crossref