Preferred Language
Articles
/
alkej-163
Drilling of FR-4 Composite Materials Using Single Pulse of Nd:YAG Laser
...Show More Authors

Laser drilling is capable of producing small, precisely positioned holes with high degree of reproductively. In this paper , IR millisecond Nd:YAG single pulsed laser was used to determine the effect of laser parameters on the drilled hole of the glass - fiber reinforced epoxy composite FR-4 sample of 2 mm in thickness . The type of laser source was GSI lumonics JK760TR Series laser 1.064μm system in a CNC cabin. The JK760TR series has a 0.3-50ms pulse length and a maximum repetition rate 500Hz with an average power of 600W. The investigation of single pulse laser drilling in this paper was based on theoretical and experimental solutions. In single pulse technique, the investigation included focal plane position fpp, pulse shape, laser peak power, and pulse duration. It was found that (-1) was the best fpp due to less taper for the drilled holes made by this level (Entrance hole =0.68, Exit hole = 0.27). To predict pulse shape effects; three types were : rectangular , rump-up and cool down, it were  examined found that rectangular pulse was efficient  more than the other types due to its ability to produce holes with less tapering as compared with others types. Also its found that all pulse shapes had the same effect on the materials microstructure . Laser peak power and pulse duration had the predominant affects on the hole dimensions and edge quality without any defect except hole tapering.  

View Publication Preview PDF
Quick Preview PDF
Publication Date
Thu Jun 01 2023
Journal Name
Sustainable Engineering And Innovation
A review of enhanced image techniques using chaos encryption
...Show More Authors

Secured multimedia data has grown in importance over the last few decades to safeguard multimedia content from unwanted users. Generally speaking, a number of methods have been employed to hide important visual data from eavesdroppers, one of which is chaotic encryption. This review article will examine chaotic encryption methods currently in use, highlighting their benefits and drawbacks in terms of their applicability for picture security.

View Publication
Scopus Crossref
Publication Date
Sun Dec 30 2018
Journal Name
Baghdad Science Journal
Electronic Structure of Copper Antimony Using Compton Scattering Technique
...Show More Authors

In this paper we present the first ever measured experimental electron momentum density of Cu2Sb at an intermediate resolution (0.6 a.u.) using 59.54 keV 241Am Compton spectrometer. The measurements are compared with the theoretical Compton profiles using density function theory (DFT) within a linear combination of an atomic orbitals (LCAO) method. In DFT calculation, Perdew-Burke-Ernzerhof (PBE) scheme is employed to treat correlation whereas exchange is included by following the Becke scheme. It is seen that various approximations within LCAO-DFT show relatively better agreement with the experimental Compton data. Ionic model calculations for a number of configurations (Cu+x/2)2(Sb-x) (0.0≤x≤2.0) are also performed utilizing free a

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Dec 04 2008
Journal Name
Journal Of Engineering
IMPROVEMENT OF SOIL USING GEOGRIDS TO RESIST ECCENTRIC LOADS.
...Show More Authors

This paper presents the results of experimental investigations to predict the bearing capacity of square footing on geogrid-reinforced loose sand by performing model tests. The effects of several parameters were studied in order to study the general behavior of improving the soil by using the geogrid. These parameters include the eccentricity value, depth of first layer of reinforcement, and vertical spacing of reinforcement layers. The results of the experimental work indicated that there was an optimum reinforcement embedment depth at which the bearing capacity was the highest when single-layer reinforcement was used. The increase of (z/B) (vertical spacing of reinforcement layer/width of footing) above 1.5 has no effect on the re

... Show More
Publication Date
Sun Dec 03 2017
Journal Name
Baghdad Science Journal
Revaluation of Student Failure Reasons Using Non-Additive Methods
...Show More Authors

In this paper, An application of non-additive measures for re-evaluating the degree of importance of some student failure reasons has been discussed. We apply non-additive fuzzy integral model (Sugeno, Shilkret and Choquet) integrals for some expected factors which effect student examination performance for different students' cases.

View Publication Preview PDF
Scopus Crossref
Publication Date
Wed Sep 30 2009
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
A Study of Forward Osmosis Using Various Drawing Agent
...Show More Authors

This research was aimed to study the osmotic efficiency of the draw solutions and the factors affecting the performance of forward osmosis process : The draw solutions used were magnesium sulfate hydrate (MgSO4.7H2O) pojtassium chloride (KCL), calcium chloride (CaCl2) and ammonium bicarbonate (NH4HCO3). It was found that water flux increases with increasing draw solution concentration, and feed solution flow rate and decreases with increasing draw solution flow rate and feed solution concentration. And also found that the efficiency of the draw solutions is in the following order:

CaCl2> KCI > NH4HCO3> MgSO4.7H

... Show More
View Publication Preview PDF
Publication Date
Wed Dec 25 2019
Journal Name
Journal Of Engineering
Removal of Cadmium from Industrial Wastewater using Electrocoagulation Process
...Show More Authors

Cadmium is one of the heavy metal found in the wastewater of many industries. The electrocoagulation offers many advantages for the removal of cadmium over other methods. So the removal of cadmium from wastewater by using electrocoagulation was studied to investigate the effect of operating parameters on the removal efficiency. The studied parameters were the initial pH, initial concentration, and applied voltage. The study experiments were conducted in a batch reactor with  with two pairs of aluminum electrodes with dimension  and 2mm in thick with 1.5 cm space between them. The optimum removal was obtained at pH =7, initial concentration = 50 mg/L, and applied voltage = 20 V and it was 90%.

View Publication Preview PDF
Crossref (8)
Crossref
Publication Date
Wed Jun 30 2010
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Removal of Lead, Cadmium, and Mercury Ions Using Biosorption
...Show More Authors

The biosorption of Pb (II), Cd (II), and Hg (II) from simulated aqueous solutions using baker’s yeast biomass was investigated. Batch type experiments were carried out to find the equilibrium isotherm data for each component (single, binary, and ternary), and the adsorption rate constants. Kinetics pseudo-first and second order rate models applied to the adsorption data to estimate the rate constant for each solute, the results showed that the Cd (II), Pb (II), and Hg (II) uptake process followed the pseudo-second order rate model with (R2) 0.963, 0.979, and 0.960 respectively. The equilibrium isotherm data were fitted with five theoretical models. Langmuir model provides the best fitting for the experimental results with (R2) 0.992, 0

... Show More
View Publication Preview PDF
Publication Date
Sun Jul 31 2016
Journal Name
International Journal Of Advanced Research
Attenuation Coefficient of Reactive Powder Concrete Using Different Energies.
...Show More Authors

View Publication
Crossref (6)
Crossref
Publication Date
Sat Sep 30 2023
Journal Name
Iraqi Geological Journal
Purification of Aqueous Solutions from Nickel Using Ceramic Waste
...Show More Authors

This study aims to test ceramic waste's capacity to remove nickel from aqueous solutions through adsorption. Ceramic wastes were collected from the Refractories Manufacturing Plant in Ramadi. Through a series of lab tests, the reaction time (5, 10, 15, 20, 25, 30, 35, 40, 45, and 50 minutes, and Ni concentrations (20, 40, 60, and 80) were tested using ceramic wastes with a solid to liquid ratio of 2g/30ml. At a temperature of 30ºC, the pH, total dissolved solids (TDS), and electrical conductivity (EC) were all measured. The equilibrium time was set at 30 min. Thereafter, the sorption (%) somewhat increased positively with the Ni concentration. Freundlich's equation showed that the adsorption intensity is 1.1827 and the Freundlich c

... Show More
View Publication
Scopus (1)
Scopus Crossref
Publication Date
Fri Jan 01 2021
Journal Name
International Journal Of Agricultural And Statistical Sciences
STATISTICAL ANALYSIS OF PATIENTS INFECTED WITH CORONAVIRUS USING MANOVA
...Show More Authors

Scopus (1)
Scopus