Preferred Language
Articles
/
alkej-140
Estimation of Volumetric Mass Transfer Coefficient in Bioreactor
...Show More Authors

 

This study is concentrated to investigate the effects of aeration and stirring speed on the volumetric mass transfer coefficient (KLa). A dynamic technique was used in estimating KLa values in order to achieve the aim of this study.

This study was done in 10L bioreactor by using two medias:-

  1. Dionized water
  2. Xanthan solution (1 g /L)

Moreover, the research covered a comparison between the obtained values of KLa.

The Xanthan solution was used because of its higher viscosity in comparison with water. It behaves similarly to the cultivation medium when organisms are cultivated in a bioreactor. Growth of organisms in the reactor leads to a change in the viscosity of the medium which affects the mass transfer.

Two variables, the effect of air flow rate (3-20 L/min) and the effect of stirring speed (250-700rpm) on KLa value were studied. Other parameters such as temperature, liquid volume, and stirrer shape and stirrer position were held constant; the results demonstrated an increase in KLa – value and mass transfer with increasing stirrer speed. Thus at higher speed, better dispersion of the bubbles was obtained. Therefore, that increased the surface / volume ratio which increased the mass transfer area i.e. KLa value.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Fri Feb 01 2013
Journal Name
Journal Of Engineering
Estimation of Flexural Strength of Plain Concrete from Ultrasonic Pulse Velocity
...Show More Authors

The aim of this study is to propose mathematical expressions for estimation of the flexural strength of plain concrete members from ultrasonic pulse velocity (UPV) measurements. More than two hundred pieces of precast concrete kerb units were subjected to a scheduled test program. The tests were divided into two categories; non-destructive ultrasonic and bending or rupture tests. For each precast unit, direct and indirect (surface) ultrasonic pulses were subjected to the concrete media to measure their travel velocities. The results of the tests were monitored in two graphs so that two mathematical relationships can be drawn. Direct pulse velocity versus the flexural strength was given in the first relationship while the second equation des

... Show More
Publication Date
Tue Nov 01 2011
Journal Name
Journal
Frequency of autoimmune diseases and estimation of P53 among vitiligo patients
...Show More Authors

KE Sharquie, AA Noaimi, SY Mohsin, 2011 - Cited by 4

View Publication
Publication Date
Fri Nov 15 2024
Journal Name
Iraqi Journal Of Science
Direction of Arrival Estimation of Meteors Echoes using Array Radio Antennas
...Show More Authors

Array antennas have an interesting role in the radio astronomy field. The array antennas allow astronomers to obtain high-resolution signals with high sensitivity to weak signals. This paper estimates the meteors' positions entering the Earth's atmosphere and develops a simulation for array antenna radar to analyze the meteor's echoes. The GNU radio software was used to process the echoes, which is a free open-source software development toolkit that provides signal processing blocks to implement in radio projects. Then, the simulation determines the azimuth and elevation of the meteors. An improved Multiple Signal Classification (MUSIC) algorithm has been suggested to analyze these echoes. The detected power of each meteor echo has

... Show More
View Publication
Scopus Crossref
Publication Date
Sun Jun 30 2013
Journal Name
Al-khwarizmi Engineering Journal
Estimation of SNR Including Quantization Error of Multi-Wavelength Lidar Receiver
...Show More Authors

 This paper comprises the design and operation of mono-static backscatter lidar station based on a pulsed Nd: YAG laser that operates at multiple wavelengths. The three-color lidar laser transmitter is based on the collinear fundamental 1064 nm, second harmonic 532 nm and a third harmonic 355nm output of a Nd:YAG laser. The most important parameter of lidar especially daytime operations is the signal-to-noise ratio (SNR) which gives some instructions in designing of lidar and it is often limit the effective range. The reason is that noises or interferences always badly affect the measured results. The inversion algorithms have been developed for the study of atmospheric aerosols. Signal-to-noise ratio (SNR) of three-color channel re

... Show More
View Publication Preview PDF
Publication Date
Tue May 16 2023
Journal Name
Journal Of Engineering
Estimation of Flexural Strength of Plain Concrete from Ultrasonic Pulse Velocity
...Show More Authors

The aim of this study is to propose mathematical expressions for estimation of the flexural strength of plain concrete members from ultrasonic pulse velocity (UPV) measurements. More than two hundred
pieces of precast concrete kerb units were subjected to a scheduled test program. The tests were divided into two categories; non-destructive ultrasonic and bending or rupture tests. For each precast unit, direct and indirect (surface) ultrasonic pulses were subjected to the concrete media to measure their travel velocities. The results of the tests were mointered in two graphs so that two mathematical relationships can be drawn. Direct pulse velocity versus the flexural strength was given in the first relationship while the second equati

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Tue Dec 29 2020
Journal Name
Journal Of Accounting And Financial Studies ( Jafs )
Electronic Payment System and its impact on the efficiency of the performance of banking: An applied research on a sample of banking sector in Iraq
...Show More Authors

The electronic payment systems are considered the most important infrastructure for the work of banks, particularly after a steady and remarkable development in information and communication technology, Which created the reality of the work of the infrastructure for these systems and these systems also become one of the most important components of infrastructure for the work of banks, cause it is one of the most important channels through which the transfer of cash, financial instruments between financial institutions in general and banking in particular.

     In order to achieve the objectives of the research, the most important to identify the concept of electronic payment systems, and its divisions, and th

... Show More
View Publication Preview PDF
Publication Date
Tue Oct 01 2013
Journal Name
Journal Of Economics And Administrative Sciences
Comparison Robust M Estimate With Cubic Smoothing Splines For Time-Varying Coefficient Model For Balance Longitudinal Data
...Show More Authors

In this research، a comparison has been made between the robust estimators of (M) for the Cubic Smoothing Splines technique، to avoid the problem of abnormality in data or contamination of error، and the traditional estimation method of Cubic Smoothing Splines technique by using two criteria of differentiation which are (MADE، WASE) for different sample sizes and disparity levels to estimate the chronologically different coefficients functions for the balanced longitudinal data which are characterized by observations obtained through (n) from the independent subjects، each one of them is measured repeatedly by group of  specific time points (m)،since the frequent measurements within the subjects are almost connected an

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Dec 01 2014
Journal Name
Journal Of Natural Sciences Research
Estimation Arginase Activity in the Serum of Uterine Fibroid Females and its Relationship with Other Parameters
...Show More Authors

The research includes a clinical study of Arginase and its relation with uterine fibroid. The normal value of arginase activity in female serum was found to be (0.52 ± 0.02 IU/L) in healthy group at age (35-55) years. The study also showed a highly significant increase in arginase activity (7.99 ± 0.23 IU/L) in serum of uterine fibroid patients group at (35-55years) in comparison to healthy.The results also indicated a highly significant increase in the level of progesterone, estradiol, prolactin, peroxynitrite and malondialdehyde in patients group. While a highly significant decrease in concentration of adiponectin in patients group was found in comparison to healthy.

Publication Date
Thu Sep 11 2014
Journal Name
Journal Of Natural Sciences Research
Estimation Arginase Activity in the Serum of Uterine Fibroid Females and its Relationship with Other Parameters
...Show More Authors

Publication Date
Thu Nov 05 2020
Journal Name
Methods And Objects Of Chemical Analysis
Derivative Spectrophotometric Determination for Simultaneous Estimation of Isoniazid and Ciprofloxacin in Mixture and Pharmaceutical Formulation
...Show More Authors

A simple analytical method was used in the present work for the simultaneous quantification of Ciprofloxacin and Isoniazid in pharmaceutical preparations. UV-Visible spectrophotometry has been applied to quantify these compounds in pure and mixture solutions using the first-order derivative method. The method depends on the first derivative spectrophotometry using zero-cross, peak to baseline, peak to peak and peak area measurements. Good linearity was shown in the concentration range of 2 to 24 µg∙mL-1 for Ciprofloxacin and 2 to 22 µg∙mL-1 for Isoniazid in the mixture, and the correlation coefficients were 0.9990 and 0.9989 respectively using peak area mode. The limits of detection (LOD) and limits of quantification (LOQ) were

... Show More