Preferred Language
Articles
/
alkej-13
Design of a Programmable System for Failure Modes and Effect Analysis of Steam-Power Plant Based on the Fault Tree Analysis
...Show More Authors

In this paper, the system of the power plant has been investigated as a special type of industrial systems, which has a significant role in improving societies since the electrical energy has entered all kinds of industries, and it is considered as the artery of modern life.

   The aim of this research is to construct a programming system, which could be used to identify the most important failure modes that are occur in a steam type of power plants. Also the effects and reasons of each failure mode could be analyzed through the usage of this programming system reaching to the basic events (main reasons) that causing each failure mode. The construction of this system for FMEA is depending on the logical relationships of the fault tree analysis for the systems that contained in the power station.

   The designing of such system could be used as an assistance tool for the specialist user (the power engineer) in identifying of all reasons and effects for any type of failures. So this is help to fastening the repairing operation of the identified failure mode to improve the efficiency of operating system as represented by the maintainability, which is a function of system reliability.

   The selection of the steam type of power generation systems for the application of this study, because this type is the most common type of Iraqi power plants. While such the designed system could be programmed to be use in another types of industrial systems.

 

 

View Publication Preview PDF
Quick Preview PDF
Publication Date
Sat Apr 30 2022
Journal Name
Kufa Journal Of Engineering
Numerical Analysis for the Response of Skirt Circular Shallow Footing Resting on Sandy Soil under vertical loads
...Show More Authors

View Publication
Crossref (1)
Crossref
Publication Date
Sun Sep 05 2010
Journal Name
Baghdad Science Journal
Design and Implementation for optical fiber communication system using frequency shift coding
...Show More Authors

In this research, optical communication coding systems are designed and constructed by utilizing Frequency Shift Code (FSC) technique. Calculations of the system quality represented by signal to noise ratio (S/N), Bit Error Rate (BER),and Power budget are done. In FSC system, the data of Nonreturn- to–zero (NRZ ) with bit rate at 190 kb/s was entered into FSC encoder circuit in transmitter unit. This data modulates the laser source HFCT-5205 with wavelength at 1310 nm by Intensity Modulation (IM) method, then this data is transferred through Single Mode (SM) optical fiber. The recovery of the NRZ is achieved using decoder circuit in receiver unit. The calculations of BER and S/N for FSC system a

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Mar 30 2012
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Numerical Analysis of Laminar Natural Convection in Square Enclosure with and without Partitions and Study Effect of pPartition on the Flow Pattern and Heat Transfer
...Show More Authors

The problem of steady, laminar, natural convective flow in an square enclosure with and without partitions is considered for Rayleigh number (103-106) and Prandtl number (0.7). Vertical walls were maintained isothermal at different temperatures while horizontal walls and the partitions were insulated. The length of partition was taken constant. The number of partitions were placed on horizontal surface in staggered arrangement from (1– 3) and ratio of partition thickness (H/L= 0.033, 0.083, 0.124). The problem is formulated in terms of the vorticity-stream function procedure. A numerical solution based on a program in Fortran 90 with the finite difference method is obtained. Representative results illustrating the effects of the thickn

... Show More
View Publication Preview PDF
Publication Date
Sun Dec 24 2017
Journal Name
Iraqi Journal Of Laser
All Fiber Chemical Liquids Refractive Index Sensor Based on Multimode Interference
...Show More Authors

A simple all optical fiber sensor based on multimode interference (MMI) for chemical liquids sensing was designed and fabricated. A segment of coreless fiber (CF) was spliced between two single mode fibers to buildup single mode-coreless-single mode (SCS) structure. Broadband source and optical signal analyzer were connected to the ends of SCS structure. De-ionized water, acetone, and n-hexane were used to test the performance of the sensor. Two influence factors on the sensitivity namely the length and the diameter of the CF were investigated. The obtained maximum sensitivity was at n-hexane at 340.89 nm/RIU (at a wavelength resolution of the optical spectrum analyzer of 0.02 nm) when the diameter of the CF reduced from 125 μm to 60 μ

... Show More
View Publication Preview PDF
Publication Date
Sat Oct 01 2016
Journal Name
Journal Of Economics And Administrative Sciences
Diagnosis of the reality of the gap for the requirements of Business Continuity Management System According to International Standard (ISO 22301: 2012) in Midland Refineries Company (Daura Refinery)
...Show More Authors

Abstract:

The current research included " Diagnosis of the reality of the gap for the requirements of Business Continuity Management System According to International Standard (ISO 22301: 2012) in Midland Refineries Company (Daura Refinery) " , for development of an administrative system for Business Continuity is considered a priority in the present day, and in the light of the organizations dependence on computers and information technology in work and communication with others . the international legitimacy (represented by the international organization for standardization (ISO)) remains the basis for matching and commitment , and the importance of the application of Business Continuity Management Syst

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Jan 24 2024
Journal Name
Pharmacia
Novel anticoagulants in the management of atrial fibrillation: A comprehensive comparative analysis
...Show More Authors

Background: Atrial fibrillation (AF) stands as the most prevalent cardiac arrhythmia, with associated risks of stroke and systemic thromboembolism. While vitamin K antagonists, specifically warfarin, have historically been the mainstay for stroke prevention in AF, they come with inherent limitations.

Aim: This review seeks to offer a comprehensive analysis of the efficacy, safety, and clinical advantages of novel oral anticoagulants (NOACs) compared to traditional warfarin in AF management.

Method: A meticulous examination of pivotal clinical trials, meta-analyses, and recent research publications was conducted.

... Show More
View Publication
Crossref (5)
Crossref
Publication Date
Tue Nov 09 2021
Journal Name
Journal Of Accounting And Financial Studies ( Jafs )
The Effect Of Time Driven Activity Based Costing in Pricing Decisions
...Show More Authors

The research aims to demonstrate the impact of TDABC as a strategic technology compatible with the rapid developments and changes in the contemporary business environment) on pricing decisions. As TDABC provides a new philosophy in the process of allocating indirect costs through time directives of resources and activities to the goal of cost, identifying unused energy and associated costs, which provides the management of economic units with financial and non-financial information that helps them in the complex and dangerous decision-making process. Of pricing decisions. To achieve better pricing decisions in light of the endeavor to maintain customers in a highly competitive environment and a variety of alternatives, the resear

... Show More
View Publication Preview PDF
Publication Date
Tue May 01 2018
Journal Name
Journal Of Engineering
Power System Stabilizer PSS4B Model for Iraqi National Grid using PSS/E Software
...Show More Authors

To damp the low-frequency oscillations which occurred due to the disturbances in the electrical power system, the generators are equipped with Power System Stabilizer (PSS) that provide supplementary feedback stabilizing signals. The low-frequency oscillations in power system are classified as local mode oscillations, intra-area mode oscillation, and interarea mode oscillations. Double input multiband Power system stabilizers (PSSs) were used to damp out low-frequency oscillations in power system. Among dual-input PSSs, PSS4B offers superior transient performance. Power system simulator for engineering (PSS/E) software was adopted to test and evaluate the dynamic performance of PSS4B model on Iraqi national grid. The results showed

... Show More
Crossref (6)
Crossref
Publication Date
Tue Dec 31 2019
Journal Name
Opcion
Analysis of Computer Textbook for the Second Intermediate Grade According to Digital Citizenship
...Show More Authors

The research aims to build a list of digital citizenship axes and standards and indicators emanating from them, which should be included in the content of the computer textbook scheduled for second grade intermediate students in Iraq, and the analysis of the above mentioned book according to the same list using the descriptive analytical method ((method of content analysis)). The research community and its sample consisted of the content of the computer textbook scheduled for the second year intermediate students for the academic year 2018-2019, and the research tool was built in its initial form after reference to a set of specialized literature and previous studies that dealt with topics related to digital citizenship, and the authenticit

... Show More
Preview PDF
Publication Date
Sun Apr 30 2017
Journal Name
Journal Of Engineering
The Effect of Fin Design on Thermal Performance of Heat Sink
...Show More Authors

      An experimental and computational study is conducted to analyze the thermal performance of heat sinks and to pick up more profound information in this imperative field in the electronic cooling. One important approach to improve the heat transfer on the air-side of the heat exchanger is to adjust the fin geometry. Experiments are conducted to explore the impact of the changing of diverse operational and geometrical parameters on the heat sink thermal
performance. The working fluid used is air. Operational parameters includes: air Reynolds number (from 23597 to 3848.9) and heat flux (from 3954 to 38357 W/m
2 ). Conformational parameters includes: change the direction of air flow and the area of conduct

... Show More
View Publication Preview PDF