Construction joints are stopping places in the process of placing concrete, and they are required because in many structures it is impractical to place concrete in one continuous operation. The amount of concrete that can be placed at one time is governed by the batching and mixing capacity and by the strength of the formwork. A good construction joint should provide adequate flexural and shear continuity through the interface.

In this study, the effect of location of construction joints on the performance of reinforced concrete structural elements is experimentally investigated.

Nineteen beam specimens with dimensions of 200×200×950 mm were tested. The variables investigated are the location of the construction joints (at midspan or at third point of the specimens), type of construction joints (vertical, inclined, and key construction joints), and presence of stirrups at these joints. The specimens were tested using 1000 kN computer controlled versatile electronic testing machine. The specimens were positioned in the machine so that the deflection at center and\or at the location of construction joint was measured at each load step.

The results of the experimental program indicated that the best location of the construction joint is at the point of minimum shear. It was found that the use of vertical construction joint has little effect on the overall behavior of beam specimens (the percentage of reduction in ultimate load capacity is in the range of 0% - 5%).

While inclined construction joints results in a noticeable reduction in strength of beams relative to the strength of beam without construction joint the percentage of reduction in ultimate load capacity is in range of 8% - 20%.The presence of stirrups at the construction joints is an important variable, which affect the type of failure and load carrying capacity. It is found that adding of stirrups across the joint results in an increase in capacity in the range of (7%- 15%) and a decrease in deflection in the range of (20%- 48%).

View Publication Preview PDF
Quick Preview PDF
Publication Date
Thu Dec 28 2023
Journal Name
Al–bahith Al–a'alami
Effect of Political Factors on the Performance of Specialized Journalists in Iraqi Electronic Journalism
...Show More Authors

This study aimed to identify the political factors influencing the performance of specialized journalists in Iraqi electronic newspapers. The significance of the study stems from the role of communication in newspapers that have established themselves in reality due to their wide dissemination, multiple uses, expanding freedom base, and the current diversity in perspectives. These newspapers highlight and publish societal issues of concern. The importance of these newspapers is associated with their creators who face various factors affecting their value and performance, whether positively or negatively. In light of this, the political factor was identified as the primary driver for other influencing factors. The

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Sep 01 2023
Journal Name
Journal Of Engineering
The Effect of Cohesive Debonding Elimination on Enhancing the Flexural Performance of Damaged Unbonded Prestressed Concrete Girders Strengthened Using NSM CFRP
...Show More Authors

This manuscript studied the effect of U-CFRP wrapped sheet anchorage on the flexural performance of unbonded post-tensioned PC members subjected to partial strand damage and strengthened using CFRP Near-Surface Mounting techniques. The program includes six girders as a control girder, a girder with strand damage of 14.2%, and four girders strengthened by CFRP laminates using the NSM technique with and without U-CFRP wrapped sheet anchorages. The testing results show that the strand damage of 14.2% has reduced the flexural strength of the girder by 5.71%. The NSM-CFRP laminate has a significant effect on flexural strength by 17.4%. On the other hand, the application of end U-CFRP wrapped sheet anchorages improves flexural

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Sat Jul 22 2023
Journal Name
Journal Of Engineering
Effect of Steel Fibers on the Properties of Refractory Free Cement Concrete
...Show More Authors

Free cement refractory concrete is a type of refractory concrete with replacing alumina cement by bonding materials such as white kaolin, red kaolin and fumed silica. The free cement refractory concrete used in many applications like Petrochemicals, iron furnaces and cement production industries. The research clarifies the effect of steel fibers with two types crimped steel fibers and hooked steel
fibers with percentages 0.5%, 1% and 1.5% by volume from weight of bauxite aggregates. The additions of steel fibers with two types gave good properties in high temperatures where the specimens keep the dimension without failure and the properties made the best. the percentage of increasing for thermal conductivity was 44% for 1.5% crimped

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Fri Oct 20 2023
Journal Name
Advances In Science And Technology Research Journal
Impact of TIG Welding Parameters on the Mechanical Properties of 6061-T6 Aluminum Alloy Joints
...Show More Authors

View Publication
Scopus (3)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Wed Oct 09 2019
Journal Name
Engineering, Technology & Applied Science Research
Numerical Analysis of Segmental Post Tensioned Concrete Beams Exposed to High Fire Temperature
...Show More Authors

The main objective of this study is to characterize the main factors which may affect the behavior of segmental prestressed concrete beams comprised of multi segments. The 3-D finite element program ABAQUS was utilized. The experimental work was conducted on twelve simply supported segmental prestressed concrete beams divided into three groups depending on the precast segments number. They all had an identical total length of 3150mm, but each had different segment numbers (9, 7, and 5 segments), in other words, different segment lengths. To simulate the genuine fire disasters, nine beams were exposed to high-temperature flame for one hour, the selected temperatures were 300°C (572°F), 500°C (932°F) and 700°C (1292°F) as recomm

... Show More
View Publication Preview PDF
Crossref (5)
Crossref
Publication Date
Tue Jan 19 2021
Journal Name
Sn Applied Sciences
Post-fire serviceability and residual strength of composite post-tensioned concrete T-beams
...Show More Authors
Abstract<p>In this study, the response of ten composite post-tensioned concrete beams topped by a reinforced concrete deck with adequate reinforcing shear connectors is investigated. Depending on the concrete compressive strength of the deck slab (20, 30, and 40 MPa), beams are grouped into three categories. Seven of these beams are exposed to a fire attack of 700 and 800 °C temperature simultaneously with or without the presence of a uniformly distributed sustained static loading. After cooling back to ambient temperature, these composite beams are loaded up to failure, using a force control module, by monotonic static loading in a four-point-bending setup with two symmetrical concentrated loads applied in </p> ... Show More
Crossref (6)
Crossref
Publication Date
Fri May 01 2020
Journal Name
Civil Engineering Journal
Post-Fire Behavior of Post-Tensioned Segmental Concrete Beams under Monotonic Static Loading
...Show More Authors

This paper presents a study to investigate the behavior of post-tensioned segmental concrete beams that exposed to high-temperature. The experimental program included fabricating and testing twelve simply supported beams that divided into three groups depending on the number of precasting concrete segments. All specimens were prepared with an identical length of 3150 mm and differed in the number of the incorporated segments of the beam (9, 7, or 5 segments). To simulate the genuine fire disasters, nine out of twelve beams were exposed to a high-temperature flame for one hour. Based on the standard fire curve (ASTM – E119), the temperatures of 300◦C (572◦F), 500◦C (932◦F), and 700◦C (1292◦F) were adopted. Consequently,

... Show More
View Publication Preview PDF
Scopus (1)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Tue Jan 19 2021
Journal Name
Sn Applied Sciences
Post-fire serviceability and residual strength of composite post-tensioned concrete T-beams
...Show More Authors
Abstract<p>In this study, the response of ten composite post-tensioned concrete beams topped by a reinforced concrete deck with adequate reinforcing shear connectors is investigated. Depending on the concrete compressive strength of the deck slab (20, 30, and 40 MPa), beams are grouped into three categories. Seven of these beams are exposed to a fire attack of 700 and 800 °C temperature simultaneously with or without the presence of a uniformly distributed sustained static loading. After cooling back to ambient temperature, these composite beams are loaded up to failure, using a force control module, by monotonic static loading in a four-point-bending setup with two symmetrical concentrated loads applied in </p> ... Show More
View Publication Preview PDF
Scopus (7)
Crossref (6)
Scopus Clarivate Crossref
Publication Date
Fri May 01 2020
Journal Name
Civil Engineering Journal
Post-Fire Behavior of Post-Tensioned Segmental Concrete Beams under Monotonic Static Loading
...Show More Authors

This paper presents a study to investigate the behavior of post-tensioned segmental concrete beams that exposed to high-temperature. The experimental program included fabricating and testing twelve simply supported beams that divided into three groups depending on the number of precasting concrete segments. All specimens were prepared with an identical length of 3150 mm and differed in the number of the incorporated segments of the beam (9, 7, or 5 segments). To simulate the genuine fire disasters, nine out of twelve beams were exposed to a high-temperature flame for one hour. Based on the standard fire curve (ASTM – E119), the temperatures of 300◦C (572◦F), 500◦C (932◦F), and 700◦C (1292◦F) were adopted. Consequently,

... Show More
Crossref (1)
Crossref
Publication Date
Thu Aug 01 2019
Journal Name
International Journal Of Geomate
SERVICEABILITY AND DUCTILITY OF PARTIALLY PRESTRESSED CONCRETE BEAMS UNDER LIMITED CYCLES OF REPEATED LOADING
...Show More Authors

View Publication
Crossref (2)