The air flow pattern in a co-current pilot plant spray dryer fitted with a rotary disk atomizer was determined experimentally and modelled numerically using Computational Fluid Dynamics (CFD) (ANSYS Fluent ) software. The CFD simulation used a three dimensions system, Reynolds-Average Navier-Stokes equations (RANS), closed via the RNG k −ε turbulence model. Measurements were carried out at a rotation of the atomizer (3000 rpm) and when there is no rotation using a drying air at 25 oC and air velocity at the inlet of 5 m/s without swirl. The air flow pattern was predicted experimentally using cotton tufts and digital anemometer. The CFD simulation predicted a downward central flowing air core surrounded by a slow
... Show MoreThyroid carcinoma incidence is increasing year after year and ranking second among top ten cancers in Iraq, especially among women, and this increased the requirement for the improvement of the molecular detection accuracy because of its potential role in the early detection. Two single nucleotide polymorphisms (rs1136410, A>G and rs1805414, A>G) in PARP1 gene were found to be associated with thyroid carcinoma risk in several genome wide association studies, therefore, this is a case-control study that was carried out to identify whether these polym
... Show MoreIn this study, Staphylococcus aureus was found to be the causative agent of furunculosis in 64 (27.5%) out of 233 Iraqi patients presented with furunculosis. 16SrRNA gene was located in all isolates. Nevertheless, mecA and lukS-lukF genes were located in 60% and 4% of S. aureus isolates, respectively. Interestingly, the lukS-lukF carrying S. aureus isolates were mecA positive as well.
Background : Coronary artery disease is theunderlying cause in approximately two thirds of
patients with systolic heart failure ;
Coronary artery angiogriphy may be useful to
define the presence ,
Anatomical characteristics ,and functional
significance of Coronary artery disease in
selected heart failure patients with or without signs
and aymptoms of Coronary artery disease.
Objectives: to verify the clinical usefulness of
coronary angiography (CA) in congestive heart
failure (CHF) patients with no history of ischemic
heart disease and to identify predictive factors for
performing coronary angiography to patients with
congestive heart failure with no obvious ischemia.
Methods :this is a cross-ses
This paper presents a vibration suppression control design of cantilever beam using two piezoelectric patches. One patch was used as an actuator element, while the other was used as a sensor. The controller design was designed via the balance realization reduction method to elect the reduced order model that is most controllable and observable. the sliding mode observer was designed to estimate six states from the reduced order model but three states are only used in the control law. Estimating a number of states larger than that used is in order to increase the estimation accuracy. Moreover, the state estimation error is proved bounded. An optimal LQR controller is designed then using the estimated states with the slid
... Show More