The study is based on the selective binding ability of the drug compound procaine (PRO) on a surface imprinted with nylon 6 (N6) polymer. Physical characterization of the polymer template was performed by X-ray diffraction and DSC thermal analysis. The imprinted polymer showed a high adsorption capacity to trap procaine (237 µg/g) and excellent recognition ability with an imprinted factor equal to 3.2. The method was applied to an extraction column simulating a solid-phase extraction to separate the drug compound in the presence of tinoxicam and nucleosimide separately and in a mixture of them with a recovery rate more than the presence of tinoxicam and nucleosimide separately and in a mixture of them with a recovery rate of more than 82%. Separation efficiency and excellent selectivity for procaine were ensured using a mixed solution injected into an HPLC technique consisting of a C18 column with a mobile phase mixture of water-acetonitrile (75:25) at pH 3.3. The study of drug control using an imprinted polymer with procaine compound showed that the complete drug release process is faster at pH1 in a maximum period of 80 min. The proposed method was successfully applied on some of the available pharmaceuticals, and it showed high selectivity for the separation of PRO, RE % was < 1.18, and RSD was less than 0.447.
Cytokines are A type of protein that is made by certain immune and non-immune cells and has an effect on the immune system. Some cytokines stimulate the immune system and others slow it down. Interleukins (ILs) can be divided into several families with more than 40 subfamily members. They can interact with a variety of cells that alter the immune system and act on a wide range of cancers. In the past several years, ILs have attracted substantial attention because of their distinct roles in CRC that provide a new and promising strategy for CRC. In general, ILs facilitate CRC by promoting tumorigenesis, tumour growth, angiogenesis, and cancer cell invasion and metastasis and inhibit CRC via complex pathways. The Bioassay Technology Human Inte
... Show MoreTo investigate the role of IL-6 and IL-8 in the immune-regulatory mechanisms involved in the recurrent spontaneous abortion of the first trimester of pregnancy. Serum level of IL-6 and IL-8 were determined in 25 women of age (20-35) years who had a spontaneous abortion of unknown aetiology during the first trimester of pregnancy .They were compared with the corresponding levels of 20 pregnant and non-pregnant women as control groups .cytokine levels were measured by (ELISA) technique .The women with spontaneous abortion had highly significant (P < 0.01) increased serum level of IL-8 and highly significant (P < 0.01 ) decreased level of IL-6 compared to those with normal pregnant and non-pregnant women. The results of this study ma
... Show MoreHashimoto Thyroiditis (HT) is the most common autoimmune thyroid disease and the commonest cause ofhypothyroidism. C-reactive protein (CRP) is synthesized in hepatocyte in response to autoimmune disorders;strongly induced by IL-6. This study aimed to estimate serum IL-6 and CRP levels in autoimmune and non-autoimmune hypothyroidism. The present study included 60 Iraqi female hypothyroid patients divided to 30autoimmune and 30 non-autoimmune, with age ranged between 24-50 years and 30 healthy controls withage ranged between 27-52 years. Serum samples were collected from study groups. The levels of thyroidhormones (TSH, T4 and T3) were determined by using automated Chemiluminescence Immunoassay (CLIA)analysis system. Detection the levels of t
... Show MoreThe present study examines the extraction of lead (Pb), cadmium (Cd) and nickel (Ni) from a contaminated soil by washing process. Ethylenediaminetetraacetic acid disodium salt (Na2EDTA) and hydrochloric acid (HCl) solution were used as extractants. Soil washing is one of the most suitable in-situ/ ex-situ remediation method in removing heavy metals. Soil was artificially contaminated with 500 mg/kg (Pb , Cd and Ni ). A set of batch experiments were carried out at different conditions of extractant concentration , contact time, pH and agitation speed. The results showed that the maximum removal efficiencies of (Cd, Pb and Ni ) were (97, 88 and 24 )&nbs
... Show MoreRoom temperature ionic liquids show potential as an alternative to conventional organic membrane solvents mainly due to their properties of low vapour pressure, low volatility and they are often stable. In the present work, the technical feasibilities of room temperature ionic liquids as bulk liquid membranes for phenol removal were investigated experimentally. In this research several hydrophobic ionic liquids were synthesized at laboratory. These ionic liquids include (1-butyl-3-methylimidazolium bis (trifluoromethylsulfonyl) imide[Bmim][NTf2], 1-Hexyl-3-methylimidazolium bis (trifluoromethylsulfonyl) imide[Hmim][NTf2], 1-octyl-3-methylimidazolium bis (trifluoromethylsulfonyl)imide[Omim][NTf2],1‐butyl
... Show MoreAn investigation was conducted effect of addition co- solvent on solvent extraction process for two types of a lubricating oil fraction (spindle) and (SAE-30) obtained from vacuum distillation unit of lube oil plant of Daura Refinery. In this study two types of co-solvents ( formamide and N-methyl, 2, pyrrolidone) were blended with furfural to extract aromatic hydrocarbons which are the undesirable materials in raw lubricating oil, in order to improve the viscosity index, viscosity and yield of produced lubricating oil. The studied operating condition are extraction temperature range from 70 to 110 °C for formamide and 80 to 120 °C for N-methyl, 2, pyrrolidone, solvent to oil ratio range from 1:1 to 2:1 (wt./wt.) for furfural with form
... Show MoreThe distribution of the intensity of the comet Ison C/2013 is studied by taking its histogram. This distribution reveals four distinct regions that related to the background, tail, coma and nucleus. One dimensional temperature distribution fitting is achieved by using two mathematical equations that related to the coordinate of the center of the comet. The quiver plot of the gradient of the comet shows very clearly that arrows headed towards the maximum intensity of the comet.
