Preferred Language
Articles
/
aOapL5wBmraWrQ4daEen
OPTIMIZATION OF SEPARATION OF THE POLYAROMATIC HYDROCARBONS USING HIGH PERFORMANCE LIQUID CHROMATOGRAPHY AND ITS APPLICATIONS IN THE AQUEOUS SOLUTIONS
...Show More Authors

Publication Date
Sun Jun 05 2016
Journal Name
Baghdad Science Journal
Determination of Water-Soluble Vitamins in Iraqi Honey Bee and Compare with Others Types by High –Performance Liquid Chromatography
...Show More Authors

High-performance liquid chromatographic methods are used for the determination of water-soluble vitamins with UV-Vis. Detector. A reversed-phase high-performance liquid chromatographic has been developed for determination of water-soluble vitamins. Identification of compounds was achieved by comparing their retention times and UV spectra with those of standards solution. Separation was performed on a C18 column, using an isocratic 30% (v/v) acetonitril in dionozed water as mobile phase at pH 3.5 and flow rate 1.0m/min. The method provides low detection and quantification limits, good linearity in a large concentration interval and good precision. The detection limits ranged from 0.01 to 0.025µg/ml. The accuracy of the method was

... Show More
View Publication Preview PDF
Crossref (4)
Crossref
Publication Date
Sat May 30 2026
Journal Name
Iraqi Journal Of Science
Simultaneous determination of a mixture of beta-lactam drugs in their pure forms and pharmaceutical preparation using high performance liquid chromatography with an ultraviolet detecto
...Show More Authors

A modern, rapid RP-HPLC-UV method was developed and validated in compliance with FDA and EMA guidelines for simultaneous quantification of 15 βlactam antibiotics) Ampicillin, Amoxicillin, cephalexin, cefotaxime, cefoxitin, cefamandole, cephalothin, piperacillin, penicillin, oxacillin, cloxacillin, nafcillin Carbenicillin, Mezlocillin and Dicloxacillin) in pharmaceutical formulations and pure forms. The method employs Column NEUCLEODUR C-18 (4.0 mm x 100 mm, 5µm particle size), at a temperature of thirty degrees Celsius, and the mobile phase was acetonitrile and KH2PO4 using gradient elution with a total separation time of 13 minutes, a flow rate of 1.3 ml/min, at = pH 4.5 for the buffer solution and the λ max was 220 nm. The met

... Show More
Publication Date
Fri Apr 01 2016
Journal Name
Journal Of Engineering
Separation of Lead (Pb2+) and Cadmium (Cd2+) from Single and Binary Salt Aqueous Solutions Using Nanofiltration Membranes
...Show More Authors

The present work reports on the performance of three types of nanofiltration membranes in the removal of highly polluting and toxic lead (Pb2+) and cadmium (Cd2+) from single and binary salt aqueous solutions simulating real wastewaters. The effect of the operating variables (pH (5.5-6.5), types of NF membrane and initial ions concentration (10-250 ppm)) on the separation process and water flux was investigated. It was observed that the rejection efficiency increased with increasing pH of solution and decreasing the initial metal ions concentrations. While the flux decreased with increasing pH of solution and increasing initial metal ions concentrations. The maximum rejection of lead and cadmium ion

... Show More
View Publication Preview PDF
Publication Date
Wed Apr 19 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Separation and determination of poly aromatic hydrocarbons in vegetables samples in Baghdad city using HPLC Technique
...Show More Authors

The Reversed Phase High Performance Liquid Chromatography (RP-HPLC) has been used for the separation of Poly aromatic hydrocarbons(PAHs) by using column Reprosil 100 C 18 which was found to be a suitable one for this purpose. The result showed that using mobile phase of (Acetonitrile-water) Reversed Phase HPLC , flow rate of (1.2 ml/min) , column temperature (30CËš) and wave length of (254nm), give a complete separation with a good resolution . The total separation time was less than 20 min. The result of the study showed that the vegetables of Baghdad city were polluted by poly aromatic hydrocarbons(PAHs) in different places where samples taken because of drainage of the heavy water ,industrial trash and trash of oil colanders. -

... Show More
Publication Date
Sun Sep 04 2016
Journal Name
Baghdad Science Journal
The Removal of Zinc from Aqueous Solutions Using Malvaparviflora
...Show More Authors

In this study, the adsorption of Zn (NO3)2 is carried out by using surfaces of malvaparviflora. The validity of the adsorption is evaluated by using atomic absorption Spectrophotometry through determination the amount of adsorbed Zn (NO3)2. Various parameters such as PH, adsorbent weight and contact time are studied in terms of their effect on the reaction progress. Furthermore, Lagergren’s equation is used to determine adsorption kinetics. It is observed that high removal of Zn (NO3)2 is obtained at PH=2. High removal of Zn (NO3)2 is at the time equivalent of 60 min and reaches equilibrium,where 0.25gm is the best weight of adsorbant . For kinetics the reaction onto malvaparviflora follows pseudo first order Lagergren’s equation.

View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Tue Jan 01 2019
Journal Name
Journal Of Global Pharma Technology
Using tobacco leaves as adsorbent for the orange-g dye removal from its aqueous solutions
...Show More Authors

The removal of commercial orange G dye from its aqueous solution by adsorption on tobacco leaves (TL) was studied in respect to different factor that affected the adsorption process. These factors including the tobacco leaves does, period of orange G adsorption, pH, and initial orange G dye concentration .Different types of isotherm models were used to describe the orange G dye adsorption onto the tobacco leaves. The experimental results were compared using Langmuir, and frundlich adsorption isotherm, the constants for these two isotherm models was determined. The results fitted frundlich model with value of correlation coefficient equal to (0.981). The capacity of adsorption for the orange G dye was carried out using various kinetic models

... Show More
Scopus (7)
Scopus
Publication Date
Fri Feb 25 2022
Journal Name
Heat And Mass Transfer
Optimization, equilibrium, kinetics and thermodynamic study of congo red dye adsorption from aqueous solutions using iraqi porcelanite rocks
...Show More Authors

View Publication
Scopus (13)
Crossref (12)
Scopus Clarivate Crossref
Publication Date
Sun Jul 01 2012
Journal Name
Food Chemistry
High performance liquid chromatographic determination of aflatoxins in chilli, peanut and rice using silica based monolithic column
...Show More Authors

A simple and rapid high performance liquid chromatographic with fluorescence detection method for the determination of the aflatoxin B1, B2, G1 and G2 in peanuts, rice and chilli was developed. The sample was extracted using acetonitrile:water (90:10, v/v%) and then purified by using ISOLUTE multimode solid phase extraction. After the pre-column derivatisation, the analytes were separated within 3.7 min using Chromolith performance RP-18e (100–4.6 mm) monolithic column. To assess the possible effects of endogenous components in the food items, matrix-matched calibration was used for the quantification and validation. The recoveries of aflatoxins that were spiked into food samples were 86.38–104.5% and RSDs were <4.4%. The method was

... Show More
View Publication
Scopus (95)
Crossref (85)
Scopus Clarivate Crossref
Publication Date
Sun Sep 01 2013
Journal Name
Baghdad Science Journal
High performance liquid chromatographic method for the determination of guaifenesin in pharmaceutical syrups and in environmental samples
...Show More Authors

A simple, precise, rapid, and accurate reversed – phase high performance liquid chromatographic method has been developed for the determination of guaifenesin in pure from pharmaceutical formulations.andindustrial effluent. Chromatography was carried out on supelco L7 reversed- phase column (25cm × 4.6mm), 5 microns, using a mixture of methanol –acetonitrile-water: (80: 10 :10 v/v/v) as a mobile phase at a flow rate of 1.0 ml.min-1. Detection was performed at 254nm at ambient temperature. The retention time for guaifenesin was found 2.4 minutes. The calibration curve was linear (r= 0.9998) over a concentration range from 0.08 to 0.8mg/ml. Limit of detection (LOD) and limit of quantification ( LOQ) were found 6µg/ml and 18µg/ml res

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Jul 21 2023
Journal Name
Journal Of Engineering
Liquid-Liquid Extraction of Metal Ions Using Aqueous Biphasic Systems
...Show More Authors

An investigation was conducted for the study of extraction of metal ions using aqueous biphasic systems. The extraction of iron, zinc and copper from aqueous sulphate media at different kinds of extractants SCN− , Cl- and I- , different values of pH of the feed solution, phase ratio, concentration of metals, concentration of extractant, concentration of polymer, and concentration of salt was investigated. Atomic absorption spectrophotometer was used to measure the concentration of iron, zinc and copper in the aqueous phase throughout the experiments. The results of the extraction experiments showed the use of SCN− as extractant, pH=2.5, phase ratio=1.5, concentration of metals 1g/l, concentration of extractant 0.06 %, concentration o

... Show More
View Publication Preview PDF
Crossref (4)
Crossref