AIM: To determine the value of the combination of thin-section 3 mm coronal and standard axial DWI and their impact in facilitating the diagnosis of acute brainstem infarction. METHODS: A cross-sectional study conducted from the 1st of April 2017 to the end of February 2018 on 100 consecutive patients (66% were male, and 34% were female) with isolated acute ischemic infarction in the brainstem. The abnormal MRI findings concerning the ischemic lesions were interpreted on standard axial 5 mm and thin-section coronal 3mm DWI. RESULTS: The mean age of the studied group was 69.2 ± 4.3 for male and 72.3 ± 2.5 years. The standard axial DWI can diagnose 20%, 6.7% and 6.7% of the infarctions in midbrain, pons and medulla oblongata respectively, while both axial and thin coronal sections together can diagnose 80% of midbrain infarctions, 93.3% of pons infarctions and 93.3% of medulla oblongata infarctions. Furthermore, the thin section coronal 3 mm section can diagnose very smaller ischemic lesion volume in comparison to the standard axial 5mm section (3.4 ± 0.45 / cm3 versus 4.6 ± 0.23 / cm3, P < 0.001) CONCLUSION: The addition of thin-section coronal DWI can facilitate the detection of brainstem ischemic lesions. We suggest its inclusion in the stroke MRI protocol.
Objectives: 1. Assessment women’s knowledge about caesarean section. 2. Determining women’s knowledge in relation to their demographic characteristics (age, level of education, and economic status). Methodology: A descriptive design was conducted on Assessment Women’ Knowledge about Cesarean Section at Maternity and Pediatric Hospital in AL-Samawa City. This study started from 26th of September 2020 up to 16th March 2021. Sample of (100) married women who were at reproductive age, pregnant (prime or multipara ) who were planned to have birth by elective cesarean section or had previous elective caesarian section without medical indication or women who had cesarean section with medical indication or emergency. Results: Results
... Show MoreIn this study, a mathematical model for the kinetics of solute transport in liquid membrane systems (LMSs) has been formulated. This model merged the mechanisms of consecutive and reversible processes with a “semi-derived” diffusion expression, resulting in equations that describe solute concentrations in the three sections (donor, acceptor and membrane). These equations have been refined into linear forms, which are satisfying in the special conditions for simplification obtaining the important kinetic constants of the process experimentally.
The study aims to determine the responsibility of nursing staff for medical errors that accompany the surgery at the hospital , which is one of the important issues that the importance of determining the responsibility of landlords nursing medical errors in the hospital was the rationale in choosing the subject. Since study included cases of errors nursing staff of (22) case. While the checklist distributed to a sample of nursing Angel Group in Sadr Teaching Hospital 's (100) nurs According to the problem, the study in determining the responsibility of nursing staff for medical errors that are not important for the hospitals. Has shown results of the study agreement members of the study sample that the clarity of the power posses
... Show MoreBackground: Adenosine mediates homodynamic
changes and resulted in the production of acute renal
failure (ARF) in female Albino-Wister rats, therefore,
adenosine level increases highly in ARF.
Objective: This experiment was designed to
investigate the effect of the adenosine antagonist
aminophylline and the adenosine agonist indomethacin on glycerol-induced ARF.
Method: Glycerol induced ARF was produced by a
single dose (10ml/kg, 50%v/v with distilled water i.m)
in rats, which were restricted to drinking water.
Aminophylline was used in our study in a dose of
25mg/kg, i.p) while the dose of indomethacin was
10mg/kg, i.p), assessment of renal function was done
by measuring blood urea
nitrogen (BUN
Photoacoustic is a unique imaging method that combines the absorption contrast of light or radio frequency waves with ultrasound resolution. When the deposition of this energy is sufficiently short, a thermo-elastic expansion takes place whereby acoustic waves are generated. These waves can be recorded and stored to construct an image. This work presents experimental procedure of laser photoacoustic two dimensional imaging to detect tumor embedded within normal tissue. The experimental work is accomplished using phantoms that are sandwiched from fish heart or blood sac (simulating a tumor) 1-14mm mean diameter embedded within chicken breast to simulate a real tissue. Nd: YAG laser of 1.064μm and 532nm wavelengths, 10ns pulse duration, 4
... Show MoreAxial spondyloarthritis (axSpA) is a chronic rheumatic inflammatory disease affecting mainly the spine and sacroiliac joints. Since the copper-to-zinc ratio (Cu/Zn) indicates an inflammatory response, the change in ratio is expected to correlate with axSpA. This study compared levels of Cu/Zn in the serum of axSpA patients. Serum samples were obtained from 53 patients with axSpA divided according to biological treatment into cohorts A and B, and 28 healthy control as cohort C. Serum levels of Cu and Zn were determined first by a fully automated chemistry analyzer TC-Matrix Plus, then the ratio was obtained. The elevated serum Cu concentration means of cohort B (189.32 ± 13.808 µg/dL) compared to cohort A (168.85 ± 7.244 µg/dL) a
... Show MoreThis paper presents a complete design and implementation of a monitoring system for the operation of the three-phase induction motors. This system is built using a personal computer and two types of sensors (current, vibration) to detect some of the mechanical faults that may occur in the motor. The study and examination of several types of faults including (ball bearing and shaft misalignment faults) have been done through the extraction of fault data by using fast Fourier transform (FFT) technique. Results showed that the motor current signature analysis (MCSA) technique, and measurement of vibration technique have high possibility in the detection and diagnosis of most mechanical faults with high accuracy. Subsequently, diagnosi
... Show MoreThis paper presents an experimental and theoretical analysis to investigate the two-phase flow boiling heat transfer coefficient and pressure drop of the refrigerant R-134a in the evaporator test section of the refrigeration system under different operating conditions. The test conditions considered are, for heat flux (13.7-36.6) kW/m2, mass flux (52-105) kg/m2.s, vapor quality (0.2-1) and saturation temperature (-15 to -3.7) ˚C. Experiments were carried out using a test rig for a 310W capacity refrigeration system, which is designed and constructed in the current work. Investigating of the experimental results has revealed that, the enhancement in local heat trans
... Show More