Considerable amounts of domestic and industrial wastewater that should be treated before reuse are discharged into the environment annually. Electrocoagulation is an electrochemical technology in which electrical current is conducted through electrodes, it is mainly used to remove several types of wastewater pollutants, such as dyes, toxic materials, oil content, chemical oxygen demand, and salinity, individually or in combination with other processes. Electrocoagulation technology used in hybrid systems along with other technologies for wastewater treatment are reviewed in this work, and the articles reviewed herein were published from 2018 to 2021. Electrocoagulation is widely employed in integrated systems with other electrochemical technologies or conventional methods for effective removal of different pollutants with less cost and sometimes over shorter durations of operation. It has also been observed that the hybrid effects besides increasing the removal efficiency can overcome the disadvantages of using electrocoagulation alone, such as less sludge formation, high cost of operation and increased life of the used electrodes, and stable flux of water with longer periods of operation. More than 20 types of other technologies have been combined efficiently with electrocoagulation
Background: The immune system of the oral cavity suffers alterations due to fixed orthodontic treatment which act as potent stimulus for oral secretory immunity. The aims of this study are to estimate the effect of fixed orthodontic appliance on the level of salivary sIgA at different time intervals, and to verify the gender difference. Materials and method: The patient's history, clinical examination, and fixed orthodontic appliances were placed for 30 Iraqi orthodontic adult patients had class II division 1 and/ or class I malocclusion (15 males and 15 females) aged 18-25 years old. The unstimulated whole saliva was collected from each sample immediately before wearing fixed appliance (control group T0 as base line), and after 2 weeks (T1
... Show MoreBackground: Calcaneus is a spongy cancellous bone with rich blood supply , its fracture heals more rapidly providing no occurrence of infection and soft tissue injury around ,no gross malposition of fragments. The associated pain leads to a major impairment in life quality. The aim of treatment for calcaneal fractures is the decrease of pain and rebuilding of walking ability for patients with normal foot shape and the ability to wear normal foot wear. To reduce complications, a minimally invasive technique for the treatment of displaced intra-articular fractures of the calcaneus was preferred to use. The purpose of this study was to determine whether the closed reduction and percutaneous K. wire fixation of displaced intra-art
... Show MoreThe banking system considered as one of the most important intermediate circle between creditor and debtors it is mean the most important funding rings in economic activity, whether finance takes the a consumer or investment form and therefore it is the main base to stimulate economic activity both on the demand side, both consumption and investment and therefore of the main motivating factors for economic growth.
The banking system depends in achieve its goals on the grants and loan recovery, or what is known credit process and according to what the importance referred to the role of the banking system, it is important to ensure the safety and efficiency of the mechanisms of banking device and safety is
... Show MoreBackground: Numerous methods have been described for achievement of Intermaxillary fixation in the treatment of fractures of facial skeleton. Conventional methods like Erich arch bars and eyelet wires are currently the most common methods for achieving intermaxillary fixation (IMF), however, they have their own disadvantages. Since 1989, IMF using intraoral self-tapping IMF screws has been introduced for treatment of mandibular fractures. The aim of this study was to evaluate the efficacy, advantages, disadvantages and potential complications associated with using of self-tapping IMF screws in the treatment of mandibular fractures. Material and Methods: Twenty patients with favorable mandibular fractures, attended to Oral and Maxillofacial
... Show MoreBackground: Trigeminal neuralgia (TN), or Tic Douloureux, is one of the most common neuropathic pains. Gamma knife stereotactic radiosurgery (GNSRS) has been considered one of the procedures for treating primary TN. Objective: This study evaluates the effectiveness of GNSRS in treating primary TN in patients who are unresponsive to medical treatment in a single-center experience. Subjects and Methods: This study was conducted on 180 patients from January 2018 to October 2021. The study utilized the Barrow Neurological Institute (BNI) pain intensity score to assess pain before and after GNSRS treatment. Results: A total of 180 patients with primary TN were included in this study, 108 female with a 1.5:1 female: male ratio. Results
... Show MoreBackground: Hyperfunction of the muscles of the upper lip is considered as the most common cause of excessive gingival display (EGD). The aim of this study was to demonstrate the effectiveness of botulinum toxin (BT) injection as a conservative treatment for EGD due to muscular hyperfunction and to compare the outcome of 2 injection methods. Material and methods: This study included 40 participants who were randomly assigned into 2 groups of 20 each, The first group received 2.5IU BT injection at 1 point per side (2-points group), while the second group received a total of 5 IU of BT at 2 points per side (4-points group). The outcome variables were the reduction in the central and lateral gingival display expressed as the difference between
... Show MoreIn this research is to study the influence of the aging heat treatment on the pitting corrosion resistance of martensitic stainless steel (MSS), where a number of specimens from martensitic stainless steel were subjected to solution treatment at 1100 oC for one hour followed by water quenching then aging in the temperatures range (500-750) oC for different holding times (1,5,10,15&20) hr. Accelerated chemical corrosion test and immersion chemical corrosion test were performed on samples after heat treatment. The results of the research showed that the pitting corrosion resistance is significantly affected by the aging temperature. Where found that the aging samples at a temperature of 500 °C have the highest ra
... Show MoreAbstract
In this paper, fatigue damage accumulation were studied using many methods i.e.Corton-Dalon (CD),Corton-Dalon-Marsh(CDM), new non-linear model and experimental method. The prediction of fatigue lifetimes based on the two classical methods, Corton-Dalon (CD)andCorton-Dalon-Marsh (CDM), are uneconomic and non-conservative respectively. However satisfactory predictions were obtained by applying the proposed non-linear model (present model) for medium carbon steel compared with experimental work. Many shortcomings of the two classical methods are related to their inability to take into account the surface treatment effect as shot peening. It is clear that the new model shows that a much better and cons
... Show More