The aim of this study was to evaluate the effects of local application of bisphosphonate gel and recombinant human bone morphogenic protein 2 gel, on titanium dental implant stability and marginal bone level. Twenty-seven patients with upper and lower missing posterior tooth/teeth were included in the study with a total of 71 implants that were used for rehabilitation. The implants were randomly divided into 4 groups: 3 study groups and 1 control. Group1; local application of bisphosphonate gel, group 2; local application of recombinant human bone morphogenic protein 2 gel, group 3; local application of a mixed formula of both gels. The gel application was immediately preimplant insertion, group 4; implant insertion without application of any medication. Using resonance frequency analyzer, implant stability was measured 4 times; primary, 8 weeks (second stage surgery), 12 weeks, and at least 14 weeks post functional loading. The level of the marginal bone around each implant were assessed using cone beam computed tomography. Four implants failed. Generally, there was a similar pattern of changes in implant stability over the study period in all groups and the stability was dependent on the healing time with no significant difference between groups. There was no significant treatment effect regarding marginal bone level differences of study groups against control, although there were significant differences on palatal and mesiodistal surfaces among the study (test) groups.
Background: Determination of local bone mineral density (BMD) with cortical thickness and bone height may offer a comprehensive description of the bone the surgeon will encounter when he or she actually sets the implant. Quantitative computed tomography (CT) (i.e., quantitative interpretation of values derived from Hounsfield units with a suitable calibration procedure) is the modality of choice to determine BMD. The aim of the present clinical study is to determine the local bone density in dental implant recipient sites using computerized tomography. Material and method: The sample consisted of (72) Iraqi patients whom referred to Al-Kharkh General hospital, Spiral CT scan Department for bone quality and quantity assessment after one wee
... Show MoreThe aim of this study is to investigate the relationship between microRNA 378 and BMP15 gene expression levels in blood samples collected from 50 healthy fertile females as controls and 50 hyperprolactinemia infertile females by quantitative real-time polymerase chain reaction (RT-qPCR). Specific primers were designed for this purpose based on the sequences of microRNA 378 and BMP15 retrieved from NCBI and designed by primer 3 software. The result assessing the expression level of BMP15 in hyperprolactinemia (HPL) was 0.220, while the control group's fold change value was 1.000. The HPL group showed downregulation in the expression of the BMP15 gene. While the fold expression values of the miRNA378 gene in the hyperprolactinemia
... Show MorePolyetheretherketone (PEEK) has favorable biomechanical properties to be used as an implant material. Unfortunately, it is hydrophobic and does not promote cellular adhesion, which could result in poor integration with bone tissue. Bio-functionalization of PEEK surface with osteogenic peptides derived from bone extracellular matrix proteins is an exciting approach to encourage bone formation around the implant. In the current study, bone-forming peptide-2 was immobilized on PEEK surface using two different methods, using dopamine and a diglycidyl ether as conjugate compounds, respectively. Peptide quantification test revealed that the two strategies resulted in the most amount of peptides were attached with 0.5 mM concentration and no furth
... Show MoreBackground: The insertion torque (IT) values and implant stability quotient (ISQ) values are the measurements most used to assess primary implant stability. This study aimed to assess the relationship between ISQ values and IT. Materials and methods: This study included 24 patients with a mean (SD) age of 47.9 (13.64) years (range 25-75 years). The patients received 42 dental implants (DI), 33 in the mandible and 9 in the maxilla. The DI were installed using the motorized method with 35 Ncm torque, When DI could not be inserted to the requisite depth by the motorized method, a hand ratchet was used and the IT was recorded as ˃ 35 Ncm. Implant stability was measured utilizing Osstell® ISQ. The secondary stability was measured after 16
... Show MoreBackground: Implant stability is a mandatory factor for dental implant (DI) osseointegration and long-term success. The aim of this study was to evaluate the effect of implant length, diameter, and recipient jaw on the pre- and post-functional loading stability. Materials and methods: This study included 17 healthy patients with an age range of 24-61 years. Twenty-two DI were inserted into healed extraction sockets to replace missing tooth/ teeth in premolar and molar regions in upper and lower jaws. Implant stability was measured for each implant and was recorded as implant stability quotient (ISQ) immediately (ISQ0), and at 8 (ISQ8) and 12 (ISQ12) weeks postoperatively, as well as post-functional loading (ISQPFL). The pattern of implant
... Show MoreMolecular farming has become one of the most significant implementations of modern biotechnology to generate modified plant crops to produce medicinal proteins. Agrobacterium is one plant genetic engineering tool that integrates genes of interest inside a host plant. In recent years, the need to produce recombinant proteins as therapeutics has growing rapidly, and human glucocerebrosidase is one of the proteins that is need to treat disease. In this study, specific primers were designed to amplify Hu-GBA1 gene from constructed pGEM-GBA plasmid which was cloned into the plant expression vector pCAMBIA1304. The generated recombinant pCAMBIA1304-GBA plasmid was used to transform A. tumefaciens LBA4404
... Show MoreBackground: The Initial (primary) stability is one of the factors that play an important role in the success of the dental implants. The purpose of this study was to evaluate the initial stability of dental implant with horizontal plate by using five analytical tests: insertion torque, removal torque, resonance frequency analysis, push-in test and pull-out test. Materials and methods: Two different lengths of dental implants (5mm and 10mm) were tested in this study; each dental implant was 4mm in diameter with a square threads shape of 1mm pitch and 0.5mm depth. The crestal area was 4.2mm diameter contained a right angle margin circumferential ring while the apical area was tapered with two self-tapping grooves. In this study, the initial s
... Show MoreBackground: the primary objective for many researches carried out in dental implantology was to reduce the period needed for functional implant loading, simvastatin (cholesterol lowering medication) had many pleiotropic effects, one of which was increasing bone density around titanium implants (1) and subsequently establishing faster osseointegrated dental implants (2,3). This study aims to reduce the period of time needed to establish secondary stability of dental implant measured in ISQ (Implant Stability Quotient) by investigating the effect of orally administered simvastatin on bone. Materials and methods: simvastatin tablets (40mg/day for three months) were administered orally for 11 healthy women aged (40-51) years old who received 1
... Show MoreBackground: Pain is one of the most reported side effects of orthodontic treatment despite the advanced technology in orthodontics. Many analgesics have been introduced to control orthodontic pain including acetaminophen and selective and nonselective nonsteroidal anti-inflammatory drugs. The great concern about these drugs is their adverse effect on rate of teeth movement. Aims: The purpose of this study was to evaluate and compare the effect of acetaminophen, ibuprofen and etoricoxib on pain perception and their influence on the rate of teeth movement during leveling and alignment stage. Methods: Forty patients were evenly and randomly distributed in a blinded way to one of four groups: placebo (starch capsules), acetaminophen 500mg th
... Show More