Preferred Language
Articles
/
a4ZkQYYBIXToZYALp4Av
Cadmium removal using a spiral-wound woven wire meshes packed bed rotating cylinder electrode
...Show More Authors

The effect of electrolysis operating parameters on the removal efficiency of cadmium from a simulated wastewater was studied by adopting response surface methodology combined with Box–Behnken Design. As a new electrode design, spiral-wound woven wire mesh rotating cylinder electrode was used for cadmium removal. Current (240–400 mA), rotation speed (200–1000 rpm), initial cadmium concentration (200–600ppm), and cathode mesh number (30–60) were chosen as independent variables while the removal efficiency of cadmium was considered as a response function. The results revealed that the rotation speed has the major effect on the removal efficiency of cadmium. Regression analysis showed good fit of the experimental data to the second-order polynomial model with a coefficient of determination (R2) value of 0.9931 and Fisher F-value of 89.82. The optimal conditions within the experimental ranges of the independent variables were a current of 345 mA, a rotation speed of 800 rpm, an initial cadmium concentration of 500 ppm, and a mesh number of 30, where concentration of cadmium was diminished from 500 to 8 ppm after 60 min of electrolysis with a specific energy consumption of 3.12 kWh kg−1 and a current efficiency of 41%.

Scopus Clarivate Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Fri Aug 15 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Irradiation effect of 780-805nm diode laser on wound healing in mice
...Show More Authors

Background: Wound healing is a complicated, interactive, integrative process involving cellular and chemotactic activity, the release of chemical mediators and associated vascular response which includes number of phases: inflammatory phase, proliferative phase and remodeling phase. Low level laser therapy can be more effective in the three overlapping phases of wound healing. Biostimulation appears to have an effect on the cellular level, by increasing cellular function and stimulating various cells. The aim of present study was to evaluate histologically the effect of 780-805 diode laser the intensity of inflammation and pattern of epithelization in mice model. Material and methods: The experimental study was performed on ninety six white

... Show More
View Publication Preview PDF
Publication Date
Wed Dec 20 2023
Journal Name
Malaysian Journal Of Microscopy
HISTOLOGICAL EVALUATION OF THE WOUND HEALING ACTIVITY OF ALLIUM AMPELOPRASUM METHANOL EXTRACT
...Show More Authors

Allium ampeloprasum extract has the potential to facilitate wound healing due to its anti-inflammatory, antioxidant, and antibacterial properties. In this study, we aimed to investigate the potential wound-healing activity of the methanol extract derived from Allium ampeloprasum. Using 30 healthy male Wester rats; control group: 15 rats; normal saline applied locally instead of plant-extract. Experimental group: 15 rats received a daily local application of 200 mg/kg of the plant extract. Then, for each healing period of 0, 5, or 10 days, each group was divided into three-subgroups: A, B, and C, each with five rats. There was a significant difference in the percentage of wound contraction between the control and experimental groups (p 0.02)

... Show More
View Publication Preview PDF
Scopus (1)
Scopus
Publication Date
Thu Oct 01 2020
Journal Name
Biochemical And Cellular Archives
DETECTION OF BACTERIAL INFECTIONS AND THEIR RESISTANCE IN BURN WOUND OF SKIN
...Show More Authors

Scopus
Publication Date
Mon Jun 30 2014
Journal Name
Al-kindy College Medical Journal
The Efficacy of fractional CO2 laser in management of surgical wound scars
...Show More Authors

Background: Atrophic postoperative and traumatic scarring are common cosmetic problems for patients. Combining CO2 laser ablation with a fractional photothermolysis system in a treatment known as ablative fractional resurfacing fulfilling the new demands for a lesser risk of side effects and minimal or no downtime.Objective: To assess the safety and efficacy of ablation fractional CO2 laser treatments for surgical scarring .methods: Twenty one patient ( 14 women, and 7 men ) with various skin types , I to IV , aged 3 to 48 years , presents with 24 scars between June and December 2012 , four patients excluded from study because they are not continued in follow up , the remaining 17 patient completed all 3 treatments & 6 months follow

... Show More
View Publication Preview PDF
Publication Date
Sat Jan 01 2022
Journal Name
Biomed Research International
Zerumbone‐Loaded Nanostructured Lipid Carrier Gel Enhances Wound Healing in Diabetic Rats
...Show More Authors

This study investigated the healing effects of topical application of zerumbone, a well‐known anti‐inflammatory compounds loaded on nanostructured lipid carrier gel (Carbopol 940) (ZER‐NLCG) on excisional wounds in streptozotocin‐induced diabetic rats. Diabetic rats with inflicted superficial skin wound were topically treated with ZER‐NLCG, empty NLCG, and silver sulfadiazine cream (SSDC) once daily for 21 days. Wound tissue samples were analyzed for proinflammatory cytokines, namely, interleukin‐6 (IL‐6), interleukin‐1 β (IL‐1β), and tumor necrosis factor‐α (TNF‐α), hydroxyproline contents, catalase,

... Show More
View Publication
Scopus (12)
Crossref (10)
Scopus Clarivate Crossref
Publication Date
Thu Nov 22 2018
Journal Name
Al-khwarizmi Engineering Journal
Experimental and Finite Elements Analysis Study of Warming Effect on Deboned Force for Embedded NiTinol Wire into Linear Low Density Polyethylene
...Show More Authors

This study presents the debonding propagation in single NiTi wire shape memory alloy into linear low-density polyethylene matrix composite the study of using the pull-out test. The aim of this study is to investigate the pull-out tests to check the interfacial strength of the polymer composite in two cases, with activation NiTinol wire and without activation. In this study, shape memory alloy NiTinol wire 2 mm diameter and linear fully annealed straight shape were used. The study involved experimental and finite element analysis and eventually comparison between them. This pull-out test is considered a substantial test because its results have a relation with behavior of smart composite materials. The pull-out test was carried out by a u

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Oct 31 2013
Journal Name
Al-khwarizmi Engineering Journal
Influence of the Applied Potential and Temperature on the Electrode position of the Lead Dioxide
...Show More Authors

The excellent specifications of electrodes coated with lead dioxide material make it of great importance in the industry. So it was suggested this study, which includes electrodeposition of lead dioxide on graphite substrate, knowing that the electrodeposition of lead dioxide on graphite studied earlier in different ways.

In this work the deposition process for lead dioxide conducted using electrolytic solution containing lead nitrate concentration 0.72 M with the addition of some other material to the solution, such as copper nitrate, nickel nitrate, sodium fluoride and cetyl trimethyl ammonium bromide, but only in very small concentrations. As for the operating conditions, the effect of change potential and temperature as well

... Show More
View Publication Preview PDF
Publication Date
Fri Aug 15 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Effect of different palatal vault shapes and woven glass fiber reinforcement on dimensional stability of high impact acrylic denture base [Part I]
...Show More Authors

Background: Change in palatal vault shape and Reinforcement of high impact acrylic denture base resin may in turn affect the dimensional accuracy of acrylic resin and affecting the fitness of the denture.This study evaluated tostudy the effect of fiber reinforcement for high-impact acrylic resin denture base with different palatal vault shapes on adaptation or gap space between the denture base and the stone cast and compare with non-fiber reinforcement and effect of palatal vault shapes on adaptation of non-reinforced and fiber reinforced high impact denture base acrylic resin Material and method: Three different palatal vault shapes were prepared on standard casts using CNC (computer numerical control) machine. 60 samples of heat polymeri

... Show More
View Publication Preview PDF
Publication Date
Fri Aug 15 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Effect of different palatal vault shapes and woven glass fiber reinforcement on dimensional stability of high impact acrylic denture base [part II]
...Show More Authors

Background: Change in palatal vault shape and Reinforcement of high impact acrylic denture base resin may in turn affect the dimensional accuracy of acrylic resin and affecting the fitness of the denture. The aim of study is to evaluate the effect of fiber reinforcement for high-impact acrylic resin denture base with different palatal vault shapes on linear dimensional change and effect of palatal vault shapes on linear dimensional changes of non-reinforced and fiber reinforced high impact denture base acrylic resin Material and method: Three different palatal vault shapes were prepared on standard casts using CNC (computer numerical control) machine. 60 samples of heat polymerized high impact acrylic resin maxillary denture base were fabri

... Show More
View Publication Preview PDF
Publication Date
Sat Oct 01 2016
Journal Name
Journal Of Non-newtonian Fluid Mechanics
On the stability of the BEK family of rotating boundary-layer flows for power-law fluids
...Show More Authors

View Publication
Scopus (7)
Crossref (6)
Scopus Clarivate Crossref