The study was conducted over the period of Oct 2018 to Apr 2019 and is aimed for the detection and estimation of four hazardous Volatile Organic Compounds VOC (benzene, toluene, ethylbenzene, and xylene) so-called (BTEX) in samples collected from the produced water in the Al-Ahdab oil field in Iraq also to track their availability in the important natural water sources around the field. These compounds pose a risk to human health as well as environment. To avoid the laborious and tiresome conventional extraction methods, water samples were collected and concentrated using solid-phase extraction technique (SPE) which is a robust and cost-effective method of sample extraction with minimal exposure and handling of solvents and then to be analyzed via a gas chromatograph with a flame ionization detector (GC-FID). All of the collected samples were found contaminated with the BTEX compounds by unacceptable limits exceeding the recommended percentages. BTEX compounds were also found in the aquatic samples outside the field. Standard deviation (SD) was ranging from 0.01-0.73. The purpose of this study was to track and monitor the BTEX concentrations in the water produced by the Al-Ahdab oilfield and compare it with the BTEX levels in the water sources near the oilfield. Which is very important to control the impact of the discharged waters on the environment.
High-performance liquid chromatographic methods are used for the determination of water-soluble vitamins with UV-Vis. Detector. A reversed-phase high-performance liquid chromatographic has been developed for determination of water-soluble vitamins. Identification of compounds was achieved by comparing their retention times and UV spectra with those of standards solution. Separation was performed on a C18 column, using an isocratic 30% (v/v) acetonitril in dionozed water as mobile phase at pH 3.5 and flow rate 1.0m/min. The method provides low detection and quantification limits, good linearity in a large concentration interval and good precision. The detection limits ranged from 0.01 to 0.025µg/ml. The accuracy of the method was
... Show MoreThe objectives of this research are to determine and find out the reality of crops structure of greenhouses in association of Al-Watan in order to stand on the optimal use of economic resources available for the purpose of reaching a crop structure optimization of the farm that achieves maximize profit and gross and net farm incomes , using the method of linear programming to choose the farm optimal plan with the highest net income , as well as identifying production plans farm efficient with (income - deviation) optimal (E-A) of the Association and derived, which takes into account the margin risk wich derived from each plan using the model( MOTAD), as a model of models of linear programming alternative programming m
... Show MoreAbstract :In this study, amygdaline in Iraqi plant seeds was extracted and isolated from their seeds matrix using reflux procedure and subsequently identified and determined by high performance liquid chromatography (HPLC) on reversed phase column of LC-18 (150mm x 4.6mm, 5?m )with actonitrile :water ( 50 : 50 ) as mobile phase at flow rate of ( 0.5 mL/min ) and detection at wavelength of 215 nm.The experimental results indicated that the linearity of calibration is in the range of 1.0-30.0 mg L-1amygdaline with the correlation coefficient of 0.9949. The limit of detection (LOD) and limit of quantitation (LOQ) for amygdaline were of 0.88 and 2.93 mg L-1 in standard pure sample. The mean recovery percent is 97.34±0.58 at 95% confidence inte
... Show MoreObjectives: The study aims: (1) To determine effectiveness of instructional health education vascular access on hemodialysis patients' knowledge, (2) To find out the association between effects of instructional health education vascular access and demographic characteristics of (age, gender and educational level). Methodology: A quasi experimental study –control study design is carried out at AL-Hussein Teaching Hospital in AL-Nasiriyah City, from 3November,2015 to 2 June, 2016. A non-probability (Purposive sample) of (80) patients with vascular access devices on maintenance hemodialysis patients divided int
Shear wave velocity is an important feature in the seismic exploration that could be utilized in reservoir development strategy and characterization. Its vital applications in petrophysics, seismic, and geomechanics to predict rock elastic and inelastic properties are essential elements of good stability and fracturing orientation, identification of matrix mineral and gas-bearing formations. However, the shear wave velocity that is usually obtained from core analysis which is an expensive and time-consuming process and dipole sonic imager tool is not commonly available in all wells. In this study, a statistical method is presented to predict shear wave velocity from wireline log data. The model concentrated to predict shear wave velocity fr
... Show MoreA rapid, sensitive and without extraction spectrophotometric method for determination of clonazepam (CLO) in pure and pharmaceutical dosage forms has been described. The proposed method was simply depended on charge transfer reaction between reduced CLO (n-donor) and metol (N-methyl-p-aminophenol sulfate) as a chromogenic reagent (π- acceptor). The reduced drug, with zinc and concentrated hydrochloric acid, produced a purple colored soluble charge-transfer complex with metol in the presence of sodium metaperiodate in neutral medium, which has been measured at λmax 532 nm. All the variables which affected the developed and the stability of the colored product such as concentration of reagent and oxidant, temperature and time of rea
... Show MoreThe petroleum sector has a significant influence on the development of multiphase detection sensor techniques; to separate the crude oil from water, the crude oil tank is used. In this paper, a measuring system using a simple and low cost two parallel plate capacitance sensor is designed and implemented based on a Micro controlled embedded system plus PC to automatically identify the (gas/oil) and (oil/water) dynamic multi-interface in the crude oil tank. The Permittivity differences of two-phase liquids are used to determine the interface of them by measuring the relative changes of the sensor’s capacitance when passes through the liquid’s interface. The experiment results to determine the liquid’s interface is sa
... Show MoreThis approach was developed to achieve an accurate, fast, economic and sensitivity to estimation of diphenhydramine Hydrochloride. The dye that produced via reaction between diphenhydramine HCl with thymol blue in acidic medium pH ≈ 4.0. The ion pair method include an optimization study to formed yellowcolored that extraction by liquid – liquid method. The product separated of complexes by using by chloroform solution measured spectrophotometry at 400 nm. The analysis data at optimum conditions showed that linearity concentration in a range of calibration curve 1.0 – 50 μg /mL, limit of detectionand limit of quantification 0.0786 and 0.2358 μg/mL respectively. The molar absorptivity and Sandell’s sensitivity were 1.8 × 10 -4 L/mo
... Show MoreThe current research aims to identify the level of mental alertness among students of the Department of Chemistry in the Faculty of Education for Pure Sciences – Ibn Al-Haytham during the academic year (2022-2023). To achieve this goal, a descriptive approach was followed. The research community was identified as all chemistry students across the four grades (first, second, third, and fourth). A sample from each grade was selected for the current research. A tool was prepared to measure mental alertness within the research sample. The researcher adopted the scale by Baer, Smith, Kristemoyer, & Tany (2006), which was developed by Al-Buhairi et al. (2014), ensuring its validity, reliability, and psychometric characteristics, making i
... Show More