Objective: To compare two insertion techniques of intramedullary interlocking nails (medial parapatellar versus intrapatellar insertion) in patients with tibial fractures. Methodology: This study was performed at Al-Kindy Teaching Hospital from August 2020 until March 2022. All 32 patients with tibial fractures (29 males and 3 females) were included for tibial closed nail fixation and then followed up for 6 months. We categorized these patients into two groups; Group A (16 patients), those treated by medial parapatellar insertion of an interlocking nail, and Group B (16 patients) with transpatellar tibial nail insertion. All patients were treated by the same surgical team. Results: The range of movement in two weeks (from extension to flexion) was up to 30°. At the end of the follow-up period, all patients in Group A had functional flexion greater than 90°, whereas three patients in Group B had limited flexion that necessitated scheduled physical therapy. Regarding the functional outcome, in group A patients and in group B patients, the mean International Knee Documentation Committee score demonstrated a better outcome in patients with medial parapatellar insertion than those in group B. According to the visual analysis score, the transpatellar insertion demonstrated more discomfort than that in the paramedial insertion group, both clinically and statistically. Conclusion: Medial entry point in intra medullary tibial nailing had less anterior knee pain in post-operative follow up.
The influence and hazard of fire flame are one of the most important parameters that affecting the durability and strength of structural members. This research studied the influence of fire flame on the behavior of reinforced concrete beams affected by repeated load. Nine self- compacted reinforced concrete beams were castellated, all have the same geometric layout (0.15x0.15x1.00) m, reinforcement details and compressive strength (50 Mpa). To estimate the effect of fire flame disaster, four temperatures were adopted (200, 300, 400 and 500) oC and two method of cooling were used (graduated and sudden). In the first cooling method, graduated, the tested beams were leaved to cool in air while in the second method, sudden, water splash was use
... Show MoreVerbs in German and Arabic are of two types: active and passive. Passive voice is a grammatical voice construction that is found in many languages. Out of grammatical perspective, each main verb has a form in the active and one in the passive known as a "genus verbi" (type of verb). In passive voice, both in German and in Arabic, the focus is on the action itself or on the result of the action; often the perpetrator is not mentioned. In German, to conjugate verbs in the passive voice, you must know the forms of werden (to become). German uses werden + the past participle and states it at the end of a sentence. In Arabic,
... Show MoreThis research dealt with shedding light on the nature of material misrepresentations, in addition to knowing the extent to which the quality of accounting information systems contributes to reducing material misrepresentations On the theoretical side, a number of sources were relied upon in dealing with the research problem and presentation of the topic, while in the practical side, it was relied on the questionnaire form, where the research sample was (accountants and auditors), where 50 forms were distributed and 50 were received, and the data was analyzed and hypotheses tested through the program Statistical spss to show the relationship between the variables. The research reached a number of conclusions, the most important of which is t
... Show MoreAn experimental program was conducted to determine the residual of composite Steel Beams-Reinforced Concrete (SB-RC) deck floors fabricated from a rolled steel beam topped with a reinforced concrete slab, exposed to high temperatures (fire flame) of 300, 500, and 700ºC for 1 hour, and then allowed to cool down by leaving them in the lab condition to return to the ambient temperature. The burning results showed that, by exposing them to a fire flame of up to 300ºC, no serious permanent deflection occurred. It was also noticed that the specimen recovered 93% of 19.2 mm of the deflection caused by burning. The recovered deflection of burned composite SB-RC deck floor at 500ºC was 40% of 77.9 mm of the deflection caused by burning with a res
... Show More(3) (PDF) Theoretical calculation of the electronic current at N3 contact with TiO2 solar cell devices. Available from: https://www.researchgate.net/publication/362780274_Theoretical_calculation_of_the_electronic_current_at_N3_contact_with_TiO2_solar_cell_devices [accessed May 01 2023].
The current research aims to describe the level of responsiveness and awareness of the officials of the General Company for Construction Industries to the indicators of the blue market strategy of (1. reduction 2. exclusion 3. increase 4. innovation) and the degree of prioritization according to their importance as well as the differences in the responses of the sample investigated according to the personal variables. As a main tool in the collection of data from the sample, which consisted of(34) officers (Associate, Manager, Section Manager, Division Officer) in the company being investigated, and computed mean, standard deviations, percentage weights,and test (x2 ) based on the SPSS. The research reached the following
... Show MoreIn this research is estimated the function of reliability dynamic of multi state systems and their compounds and for three types of systems (serial, parallel, 2-out-of-3) and about two states (Failure and repair) depending on calculating the structur function allow to describing the behavior of
Abstract: Reflection optical fibre Humidity sensor is presented in this work, which is based on no core fibre prepared by splicing a segment of no core fibre (NCF) at different lengths 1-6 cm with fixed diameter 125 µm and a single mode fibre (SMF). The range of humidity inside the chamber is controlled from 30% to 90% RH at temperature ~ 30 °С. The experimental result shows that the resonant wavelength dip shift decreases linearly with an increment of RH% and the sensitivity of the sensor increased linearly with an increasing in the length of NCF. However, a high sensitivity 716.07pm/RH% is obtained at length 5cm with good stability and reputability. Furthermore, the sensor is shif
... Show MoreThe catalytic cracking of three feeds of extract lubricating oil, that produced as a by-product from the process of furfural extraction of lubricating oil base stock in AL-Dura refinery at different operating condition, were carried out at a fixed bed laboratory reactor. The initial boiling point for these feeds was 140 ºC for sample (1), 86 ºC for sample (2) and 80 ºC for sample (3). The catalytic cracking processes were carried out at temperature range 325-400 ºC and initially at atmospheric pressure after 30 minutes over 9.88 % HY-zeolite catalyst load. The comparison between the conversion at different operating conditions of catalytic cracking processes indicates that a high yield was obtained at 375°C, according to gasoline pr
... Show More