Preferred Language
Articles
/
_hZa1YgBVTCNdQwCyYIi
Comparism Between Transvaginal Cervical Length Measurement and Digital Examination in Prediction of Imminent preterm Delivery
...Show More Authors

BACKGROUND: Preterm labour is a major cause of perinatal morbidity and mortality, so it is important to predict preterm delivery using the clinical examination of the cervix and uterine contraction frequency. New markers for the prediction of preterm birth have been developed such as transvaginal ultrasound measurement of cervical length as this method is widely available. OBJECTIVE: To determine, whether transvaginal cervical length measurement predicts imminent preterm delivery better than digital cervical length measurement in women presented with preterm labour and intact membranes. PATIENTS AND METHODS: Two hundred women presented with preterm labour between 24 and 36+6 weeks of gestation were included in this study. All women subjected for digital and transvaginal ultrasound cervical length measurement and the outcome measures were occurrence of preterm delivery within 48 hours and within 7 days. RESULTS: Assessment of cervical length measurement using transvaginal ultrasound for the 200 women presented with preterm labour with intact membrane revealed that 8 (4%) delivered within 48 hours and 16 (8%) delivered within 7 days. According to the Bishop score, the test was positive if the Bishop score was ≥8, or 4-7 with cervical length ≤30 mm. The cut-off value for transvaginal ultrasound cervical length considered as 30 mm in the study group. CONCLUSION: Transvaginal sonographic measurement of cervical length can predict imminent preterm delivery in women presented with preterm uterine contractions and Bishop score between 4 - 7 compared with digital cervical length measurement.

View Publication
Publication Date
Wed Jun 30 2010
Journal Name
Al-kindy College Medical Journal
A prospective study of colonoscopic examination at al-kindy teaching hospital
...Show More Authors

Background: Fiber-optic endoscopy is an important
investigation of the large intestine, whether or not the
radiologist (barium enema) has discovered a lesion in
the bowel. Colonoscopy affords a unique opportunity
to direct visualization of entire colonic mucosa. At
the same time, the physician can obtain biopsy specimens, remove polyps, and decompress volvuli.
Most experienced endoscopists and well prepared
patients can reach the cecum in over 90% of patients.
If colonoscopy is properly performed, it has a low
risk of complications, such as perforation and bleeding.
Methods: A total of 70 consecutive patients admitted
to Endoscopy department at Al-Kindy Teaching hospital from September- 2008 to July-2009.

... Show More
View Publication Preview PDF
Publication Date
Wed May 29 2024
Journal Name
Pharmacia
Formulation, in vitro and in vivo evaluation of olanzapine nanoparticles dissolving microneedles for transdermal delivery
...Show More Authors

Olanzapine (OLZ) is classified as a typical antipsychotic drug utilized for the treatment of schizophrenia. Its oral bioavailability is 60% due to its low solubility and pre-systemic metabolism. Hence, the present work aims to formulate and evaluate OLZ nanoparticles dissolving microneedles (MNs) for transdermal delivery to overcome the problems associated with drug administration orally. OLZ nanoparticles were prepared by the nanoprecipitation method. The optimized OLZ nanoparticle formula was utilized for the fabrication of dissolving MNs by loading OLZ nanodispersion into polydimethylsiloxane (PDMS) micromould cavities, followed by casting the polymeric solution of polyvinylpyrrolidone(PVP-K30) and polyvinyl alcohol (PVA) to form

... Show More
View Publication
Scopus Clarivate Crossref
Publication Date
Mon Jun 01 2020
Journal Name
Annals Of Tropical Medicine And Public Health
Molecular Detection of High-Risk Human Papillomavirus Genotypes from Cervical Lesions in Baghdad
...Show More Authors

Objective Using two complementary techniques of virus detection human papillomavirus (HPV)[capture of hybrids (CH) and polymerase chain reaction (PCR)], relate the cytological study and/or cervical biopsy with high-risk HPV (HPV-HR) genotypes presence, as well as relating their viral load (VL). Methods About 272 women, who presented most cell alterations compatible with lesions cervical HPV, which has been detected in all high risk by the CH method and HPV genotype detection by PCR. Results In 22% of the patients it was not detected HPV DNA. Genotype 16 and/or 18 was prevalent and was found in 33% of the 212 women studied, meanwhile, mixed infections were found by several genotypes in 25%. In as for the histological lesions found, in 61 pat

... Show More
View Publication
Scopus (2)
Scopus Crossref
Publication Date
Sun Jul 04 2010
Journal Name
Journal Of The Faculty Of Medicine Baghdad
Epidemiological characteristics of women with cervical erosion in Al-Sader city, Baghdad, Iraq.
...Show More Authors

Background: Cervical erosion (CE) is a common finding on routine pelvic examination during the fertile years. Published articles on CE in Iraq are scarce; therefore this study was carried out.
Methods: A total of 100 non pregnant women had CE attending a private clinic in Al-Sader city, Baghdad, was included in this study. Pelvic examination was done; demographic data and gynaecological history were obtained.
Results: The age of women was 27.1 ± 5.9 years with 7.3 ±2.9 educational years. Mucopurlent vaginal discharge was a complaint in 49% of women, and a watery vaginal discharge was a complaint in a similar percent. Thirty four of women were oral contraceptive users and 11% were using intrauterine c

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Dec 01 2002
Journal Name
Iraqi Journal Of Physics
FLUORESCENCE LIFETIME MEASUREMENT OF C5H6 AND C6D6
...Show More Authors

Absorption and lifetime measurements were made for C6H6. and C6D6 molecules in pure solid phase and in solid matrices of Ar, N2, CO, and CO2. All measurement are made at low temperatures ranging between 12-50 K. A modified least square fitting deconvolution was utilized to measure the fluorescence lifetime with an error less than 1%. The results show that the use of matrix isolation technique offer a unique environment that minimize the perturbation of the molecular or atomic system and hence facilitate spectral analysis.

View Publication Preview PDF
Publication Date
Tue Mar 30 2021
Journal Name
Baghdad Science Journal
Delivery Route Management based on Dijkstra Algorithm
...Show More Authors

For businesses that provide delivery services, the efficiency of the delivery process in terms of punctuality is very important. In addition to increasing customer trust, efficient route management, and selection are required to reduce vehicle fuel costs and expedite delivery. Some small and medium businesses still use conventional methods to manage delivery routes. Decisions to manage delivery schedules and routes do not use any specific methods to expedite the delivery settlement process. This process is inefficient, takes a long time, increases costs and is prone to errors. Therefore, the Dijkstra algorithm has been used to improve the delivery management process. A delivery management system was developed to help managers and drivers

... Show More
View Publication Preview PDF
Scopus (1)
Scopus Clarivate Crossref
Publication Date
Wed Jul 07 2021
Journal Name
International Journal Of Applied Pharmaceutics
APPLICATION OF 3D PRINTING IN INNOVATED DRUG DELIVERY: A REVIEW
...Show More Authors

Increasing requests for modified and personalized pharmaceutics and medical materials makes the implementation of additive manufacturing increased rapidly in recent years. 3D printing has been involved numerous advantages in case of reduction in waste, flexibility in the design, and minimizing the high cost of intended products for bulk production of. Several of 3D printing technologies have been developed to fabricate novel solid dosage forms, including selective laser sintering, binder deposition, stereolithography, inkjet printing, extrusion-based printing, and fused deposition modeling. The selection of 3D printing techniques depends on their compatibility with the printed drug products. This review intent to provide a perspecti

... Show More
View Publication
Scopus (1)
Crossref (1)
Scopus Crossref
Publication Date
Wed May 15 2024
Journal Name
Al-rafidain Journal Of Medical Sciences ( Issn 2789-3219 )
Preparation and Optimization of Olanzapine as Transdermal Nanoparticles Delivery System
...Show More Authors

Background: The treatment of schizophrenia typically involves the use of olanzapine (OLZ), a typical antipsychotic drug that has poor oral bioavailability due to its low solubility and first-pass effect.  Objective: To prepare and optimize OLZ as nanoparticles for transdermal delivery to avoid problems with oral administration. Methods: The nanoprecipitation technique was applied for the preparation of eight OLZ nanoparticles by using different polymers with various ratios. Nanoparticles were evaluated using different methods, including particle size, polydispersity index (PDI), entrapment efficiency (EE%), zeta potential and an in vitro release study. The morphology was evaluated by a field emission scanning electron microscope (F

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Sun Nov 02 2014
Journal Name
Iraqi Journal Of Pharmaceutical Science
preparation and evaluation of meloxicam microsponges as transdermal delivery system
...Show More Authors

Publication Date
Mon Mar 27 2017
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Preparation and Evaluation of Meloxicam Microsponges as Transdermal Delivery System
...Show More Authors

The aim of present study was to develop gel formulation of microsponges of poorly soluble drug meloxicam (MLX) in order to enhance the release and dissolution of MLX which is the limitation for preparation in topical forms. Also skin delivery is an alternative administration for MLX that can minimize gastrointestinal (GI) side effects and improve patient compliance. The microsponges of MLX were prepared by quasi-emulsion solvent diffusion method.  The effects of drug:polymer ratio, stirring time and Eudragit polymer type on the physical characteristics of microsponges were investigated and characterized for production yield, loading efficiency, particle size, surface morphology, and in vitro drug release from microsponges. The selec

... Show More
View Publication
Crossref (1)
Crossref