Determination of Eugenol in Personal-Care Products by Dispersive Liquid-Liquid Microextraction Followed by Spectrophotometry Using <i>p</i>-Amino-<i>N,N</i>-dimethylaniline as a Derivatizing Agent
...Show More Authors

Two simple methods for the determination of eugenol were developed. The first depends on the oxidative coupling of eugenol with p-amino-N,N-dimethylaniline (PADA) in the presence of K3[Fe(CN)6]. A linear regression calibration plot for eugenol was constructed at 600 nm, within a concentration range of 0.25-2.50 μg.mL–1 and a correlation coefficient (r) value of 0.9988. The limits of detection (LOD) and quantitation (LOQ) were 0.086 and 0.284 μg.mL–1, respectively. The second method is based on the dispersive liquid-liquid microextraction of the derivatized oxidative coupling product of eugenol with PADA. Under the optimized extraction procedure, the extracted colored product was determined spectrophotometrically at 618 nm. A linear plot within a concentration range of 0.05–1.65 μg.mL–1 (r = 0.9997) was constructed. The LOD and LOQ were 0.053 and 0.177 μg.mL–1, respectively. Both methods were tested for the analysis of eugenol in commercial personal-care products, and the results confirmed that the procedures are accurate, precise, and reproducible (RSD < 1%).

Scopus Clarivate Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Fri Oct 20 2023
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
A Novel Approach of CFIA Technique for Assaying of Furosemide (Sulfa Drug) as Antibacterial Agent in Pharmaceutical and Biological Samples Using Potassium Ferricyanide as Oxidizing Agent
...Show More Authors

Furosemide drug determination in pharmaceutical and biological urine samples using a novel continuous flow-injection analysis technique that is simple, rapid, sensitive and economical. The complex formed by the reaction of furosemide and O-phenylenediamine with oxidative agent K3[Fe(CN)6] to produce an orange-yellow colored product at 460 nm was the basis for the proposed method.  The proposed method’s linearity ranges (3-100) μg.mL-1and (1-50) μg.mL-1 for CFIA/merging zone methods and batch .The detection limit and Limit of quantification values were 2.7502 μg.mL-1  and 9.1697 μg.mL-1 the relative standard deviation was 0.7143 %, and the average recovery is 98.80%

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Mar 15 2018
Journal Name
Moroccan Journal Of Chemistry
Corrosion Protection of Carbon Steel in seawater by alumina nanoparticles with poly (acrylic acid) as charging agent
...Show More Authors

Nanostructured Al2O3has been applied as a protective coating against corrosion of the carbon steel (C.S) in seawater environment (3.5% NaCl) at temperatures range (298-328)K. Aluminananoparticles were deposited on carbon steel substrates by cathodic electrophoretic deposition (EPD) with ethanol as suspension medium and poly(acrylic acid) (PAA) as polymeric charging agent. Meanwhile, thesurface morphology was examined using Atomic-force microscopy (AFM). The cross-section AFM showed that the particles sizes for the Al2O3 NPs is around 60-80 nm. The anticorrosion behaviour of coated C.S was investigated in 3.5% NaCl at temperature range 298-328 K by potentiodynamic polarization measurements. Results show that using PAA in suspension coat incr

... Show More
View Publication Preview PDF
Scopus (12)
Scopus
Publication Date
Fri Jul 21 2023
Journal Name
Journal Of Engineering
Bubble Size Distribution In Gas-Liquid Dispersion Column
...Show More Authors

The present work investigates the effect of; superficial air velocities of: 1, 3, and 6 cm/s for two types of perforated distributor on hydrodynamic characteristic in a gas-liquid dispersion column of; air-water, and airaqueous-n-propanol solution. Bubble distribution, gas holdup, and power consumption are parameters take in consideration. Experimental work was carried out in perspex column of 8.5 cm inside diameter and 1.5 m height. Two types of bubble generator (perforated plate) were fixed at the bottom of the column; plate A (99 holes of 0.5 mm diameter and free area of 0.34%), plate B (20 holes of 1.5 mm diameter and free area of 0.62%). Photographic technique was used to measure the bubble parameters. The experimental results were

... Show More
View Publication Preview PDF
Publication Date
Mon Jan 05 2009
Journal Name
J. Duhok Univ
The role of red pigment produced by Serratia marcescens as antibacterial and plasmid curing agent
...Show More Authors

Preview PDF
Publication Date
Sat Mar 01 2014
Journal Name
Food Chemistry
Micro-solid phase extraction with liquid chromatography–tandem mass spectrometry for the determination of aflatoxins in coffee and malt beverage
...Show More Authors

A single step extraction-cleanup procedure using porous membrane-protected micro-solid phase extraction (μ-SPE) in conjunction with liquid chromatography–tandem mass spectrometry for the extraction and determination of aflatoxins (AFs) B1, B2, G1 and G2 from food was successfully developed. After the extraction, AFs were desorbed from the μ-SPE device by ultrasonication using acetonitrile. The optimum extraction conditions were: sorbent material, C8; sorbent mass, 20 mg; extraction time, 90 min; stirring speed, 1000 rpm; sample volume, 10 mL; desorption solvent, acetonitrile; solvent volume, 350 μL and ultrasonication period, 25 min without salt addition. Under the optimum conditions, enrichment factor of 11, 9, 9 and 10 for AFG2, AFG1

... Show More
View Publication
Scopus (60)
Crossref (58)
Scopus Clarivate Crossref
Publication Date
Tue Dec 15 2020
Journal Name
Al-academy
Evaluating Industrial Products emotionally by Using Emojis: محمد علي حسين القيسي
...Show More Authors

Researches in the field of evaluation of industrial products emotionally are internationally new and non-existing in the Arabic speaking countries, which is considered the crux of the problem in the current research, in addition to the need of the designers and design students to know how to measure the emotional responses for the industrial product in order to get benefit from them in their designs. The research objective is to get a tool that uses emojis in measuring the emotional responses for the products. The researcher designed an emotional verbal wheel and emojis wheel. The sample of the research consisted of (7) chairs different in design and use, and the respondents were (89) students. The most important results are:
1- Desi

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Apr 12 2010
Journal Name
مجلة بغداد للعلوم/ كلية العلوم للبنات
دراسات حركية لمتناظرات انزيم الاسبارتيت امينوترانسفريز AST,I,II,III,IV المنقاة جزئيا من ادرار المرضى المصابين بالعجز الكلوي المزمن. مجلة بغداد للعلوم/ كلية العلوم للبنات 2010
...Show More Authors

Publication Date
Thu Oct 01 2020
Journal Name
Journal Of Engineering
Chemical-Free Greywater Treatment Using Aeration, Sedimentation, Followed by Granular Activated Carbon Filter (GAC) -A Case Study of Baghdad city household
...Show More Authors

Greywater is a possible water source that can be improved for meeting the quality required for irrigation. Treatment of greywater can range from uncomplicated coarse filtration to advanced biological treatment. This article presents a simple design of a small scale greywater treatment plant, which is a series of physical and natural processes including screening, aeration, sedimentation, and filtration using granular activated carbon filter and differentiates its performance with sand filter. The performance of these units with the dual filter media of (activated carbon with sand) in treatment of greywater from Iraqi house in Baghdad city during 2019 and that collected from several points including washbasins, kitchen si

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Sun Jun 11 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Metal (II) Complexes with Tridentate N, N,O Ligand: Synthesis, Characterization and Biological Studies 
...Show More Authors

 The preparation of some new coordination compounds for nikel (II), manganese (II), copper (II), cobalt (II)and mercury (II), with ligand obtained from Benzoinand2-amino pyridine.The ligand[6-(2-hydroxy-1,2-diphenylethylideneamino)pyridin-3-ylium)](L) was made from reactin ethanol with metal salts in (1:1)(metal : ligand)ratio.[MLCl] was the inclusive formula of the complexes where M= Mn(II),Co(II),Ni(II),Cu(II) and Hg(II). Metal analysis by electronic spectra, atomic absorption ,infrared spectra, 1H&13C-NMR(only ligand)spectral studies, magnetic moment and molar conductance measurements used to describe the compounds.The determinations indicated that the ligand coordinates with the metal (II) ion in neutral tridentate manner th

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Wed Sep 30 2015
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Extraction of Essential Oils from Citrus By-Products Using Microwave Steam Distillation
...Show More Authors

The main objectives of this research is to extract essential oil from: orange ( citrus sinensis), lemon( citrus limon) and mandarin( citrus reticulata) peels by two methods: steam distillation (SD) and microwave assisted steam distillation (MASD), study the effect of extraction conditions (weight of the sample, extraction time, and microwave power, citrus peel type) on oil yield and compare the results of the two methods, the resulting essential oil was analyzed by Gas Chromatography (GC).

   Essential oils are highly concentrated substances used for their flavor and therapeutic or odoriferous properties, in a wide selection of products such as foods, medicines and cosmetics. Extracti

... Show More