This research focuses on improvement of the corrosion behaviour of commercial pure titanium (Ti) grade II when exposed to Hank’s solution through different surface treatments. The disc shape of titanium samples were constructed to be divided according to their surface treatment. The first experimental group the Ti sample was exposed to computer numerical control (CNC) fiber laser machine. Whereas, the other experimental group the Ti sample was only coated with Polyetherketon keton (PEKK) by using carbon dioxide (CO2) laser technique while the last experimental group the Ti sample was treated with CNC fiber laser followed by PEKK coating by using CO2 laser technique. All were compared with the untreated control group. The electrochemical action of the samples was tested via polarization test to assess the corrosion rate. The Results showed an improvement in corrosion resistance for all experimental groups, specifically group four showed the lowest electrical current due to the laser surface treatment followed by PEKK coating which acts as a barrier preventing electrolytic attack.
In the present study, the effects of brake pad particles of lung and liver histological sections were evaluated for (60) adult male mice. The animals were divided into three groups ( A,B,C) according to the periods of exposure (4, 8, and 12) weeks respectively exposed to brake pad particles in addition to the control groups (F) exposed to fresh air only. A special inhalation chamber designed locally has been used to expose the animals. The exposure to brake pad particles was (2.228) µg/m³ for 30 min/day, 5 days/week for (4,8and12) weeks respectively.
The examination in group (A) of the histological sections of the lung showed the thickness of interalveolar septa. Also, a congestion of alveolar capillary was marked indicat
... Show MoreThis study was conducted to evaluate the prevalence rate of
toxoplasmosis among 294 rheumatoid arthritis (RA) patients treated with
methotrexate (MTX), 50 RA patients without treatment and 50 samples as
healthy control. Blood samples were collected and the presence of T.gondii
IgG and IgM antibodies was determined by using Enzyme linked
immunosorbent assay (ELISA). Tumor necrosis factor alpha (TNF-α) was
also estimated in serum of all subjects by using ELISA method too. The
seroprevalence of toxoplasmosis IgM and IgG in RA+MTX was
60(20.408%), and 98(33.33%), in RA patients 4(8%), and 18(36%) while,
it was 2(24%), 6(12%) in healthy group. Tumor necrosis factor alpha
(TNF-α) was also estimated in serum of a
Objective: to evaluate the results of (Modification of Russe method) in treatment of nonunion fracture scaphoid bone by bone graft with external splintage (plaster of paris cast (pop ). Methods:Prospective study done on 26 patients (24 male, 2 female), age range between 25-42 years (mean age 34 years), fracture site at middle 1/3 with minimal displacements with no carpal bone or radial bone injury, technique of Matte- Russe method (explore the bone through volar approach using bone graft from iliac crest (cortico-cancellous peg plus cancellus bone) with thumb spica for 90 days with period of follow up 12-18 months. Results: out of 26 patients treated by this method , 23 patients (88.5%) union was achieved radiologically by the end of 3rd mo
... Show MoreObjective: to evaluate the results of (Modification of Russe method) in treatment of nonunion fracture scaphoid bone by bone graft with external splintage (plaster of paris cast (pop ).
Methods:Prospective study done on 26 patients (24 male, 2 female), age range between 25-42 years (mean age 34 years), fracture site at middle 1/3 with minimal displacements with no carpal bone or radial bone injury, technique of Matte- Russe method (explore the bone through volar approach using bone graft from iliac crest (cortico-cancellous peg plus cancellus bone) with thumb spica for 90 days with period of follow up 12-18 months.
Results: out of 26 patients treated by this method , 23 patients (88.5%) union was achieved radiologically by the end
Background : It had been indentified by histological, histochemical and morphometrical studies that peganum harmala is a mammogenic herb and borage officinalis is a lactogenic one . To complete our investigation about these two herbs , we performed electron microscopical study.
Materials and methods : Rats were grouped according to their physiological status into three groups . Each group was subdivided in to three subgroups : one control and two experimental . The two experimental group were treated daily; the 1st one with an aqueous extract of peganum harmala seeds and the 2nd with an aqueous extract of borage officinalis flowers . After two weeks of treatment , mammary glands were employed for electron
In this study, the consequences of treatment with brake pad particles on kidney and spleen were evaluatedthrough microscopic anatomy sections for 60 male albino mice. The animals were divided into six groups, the first three groups (A,B,C) were exposed to brake pad particles depending on periods of exposure (4, 8, and 12weeks, respectively), while the other three groups were control groups,designated asF, which were exposed to laboratory fresh air only. A special locally-designed inhalation chamber was used to expose the animals. The exposure dose to brake pad particles (total suspended particles) was 2.228 µg/m³ for 30 min/day, 5 days/week,4, 8 and 12 weeks.The statistical analysis showed that the weights of organs for both
... Show MoreBackground : It had been indentified by histological, histochemical and morphometrical studies that peganum harmala is a mammogenic herb and borage officinalis is a lactogenic one . To complete our investigation about these two herbs , we performed electron microscopical study . Materials and methods : Rats were grouped according to their physiological status into three groups . Each group was subdivided in to three subgroups : one control and two experimental . The two experimental group were treated daily; the 1st one with an aqueous extract of peganum harmala seeds and the 2nd with an aqueous extract of borage officinalis flowers . After two weeks of treatment , mammary glands were employed for electron microscopical study . Resu
... Show MoreLasers, with their unique characteristics in terms of excellent beam quality, especially directionality and coherency, make them the solution that is key for many processes that require high precision. Lasers have good susceptibility to integrate with automated systems, which provides high flexibility to reach difficult zones. In addition, as a processing tool, a laser can be considered as a contact-free tool of precise tip that became attractive for high precision machining at the micro and nanoscales for different materials. All of the above advantages may be not enough unless the laser technician/engineer has enough knowledge about the mechanism of interaction between the laser light with the processed material. Several sequential phenom
... Show MoreThis work involves the development of ceramic coating to steel surfaces (enamel).This enamel high quality consisted of two ceramic layers to ensure excellent bonding with the steel surfaces. The first is called the ground coat which proved bonding between the steel base and the second outer layer called the cover coat. Various concentrations of TiO2 were separately added to the mixture of the cover coat, resulting in to much better densification of the ceramic outer layer, the hardness, thermal shock resistances, and glossiness were improved also .Moreover this addition has raised the corrosion resistances of the ceramic in harsh acidic environment and at higher temperatures Also this enamel was used to protect the surfaces of steels whi
... Show MoreObjectives Dental implant is a revolution in dentistry; some shortages are still a focus of research. This study use long duration of radiofrequency (RF)–magnetron sputtering to coat titanium (Ti) implant with hydroxyapatite (HA) to obtain a uniform, strongly adhered in a few micrometers in thickness. Materials and Methods Two types of substrates, discs and root form cylinders were prepared using a grade 1 commercially pure (CP) Ti rod. A RF–magnetron sputtering device was used to coat specimens with HA. Magnetron sputtering was set at 150 W for 22 hours at 100°C under continuous argon gas flow and substrate rotation at 10 rpm. Coat properties were evaluated via field emission scanning electron microscopy (FESEM), scanning electro
... Show More