Preferred Language
Articles
/
_RekNJIBVTCNdQwCy6eP
Serum and urine apolipoprotien A1 (ApoA1) as biomarkers in bladder cancer

Bladder cancer (BC) is the predominant malignant neoplasm in the urinary system and ranks as the tenth most prevalent malignant tumor worldwide. Compared with females, males displayed a four-fold more common incidence of bladder cancer. It mainly affects men. Bladder cancer is the fourth most prevalent neoplasm in males. The most important protein that makes up high density lipoprotein (HDL), ApoA-I apolipoprotein A1 is essential in regulating the right amount of cholesterol. Multiple inquiries have demonstrated that APOA1 plays a pivotal role in the progression, infiltration, and spread of tumors. Objectives. The objective of this study was to measure the level of urine to serum apolipoprotein A1 in patients suffering from bladder cancer and investigate the impact of variations to this nanotechnology on the development of the cancer. Material and methods. The study collected 45 blood and urine samples from individuals diagnosed with bladder cancer at Ghazi Hariri Hospital for Specialized Surgery. The samples included both males and females of various ages (61.47±11.28 years). Additionally, 45 blood and urine samples were collected from individuals without the disease. The samples were analyzed using an ELISA method to measure the levels of apolipoprotein A1 in the serum and urine of both groups, and the data collection period spanned from January 2023 to June 2023. Result. The average levels of serum and urine apolipoprotein A1 in the patients' group (14.18±2.62ng/ml, 20.04±4.67ng/ml) were significantly higher than the average levels in the control group (8.21±1.35, 8.94±1.74), with p-values of <0.001 and ≤0.001, respectively. The blood concentration of apolipoprotein A1 showed a significant positive moderate connection with the concentration of apolipoprotein A1 in urine (r=0.45, p<0.001). Conclusion. The mean and SD of serum apolipoprotein A1 in the patients group were higher than control group and urine apolipoprotein A1 in the patients group were higher than control group can be utilized as biomarkers for detecting bladder cancer. However, urine apolipoprotein A1 is a superior biomarker compared to serum apolipoprotein A1 due to its association with several other diseases.

Scopus Crossref
View Publication
Publication Date
Fri May 15 2020
Journal Name
International Journal Of Research In Pharmaceutical Sciences
Urodynamic findings of bladder dysfunction in patients with Type 2 DM

Bladder dysfunction is one of the most common complications of diabetes, even exceeding nephropathy or peripheral neuropathy. Diabetic cystopathyaffects patients in both sexes, and its prevalence increases over time with diabetes; our concern is to evaluate the urodynamic findings of bladder dysfunction in diabetic patients.A cross sectional study conducted at Ghazi Al-Hariri Surgical specialized hospital during the period from the firsts of January 2018 to the end of Mar 2019, in which 118 diabetic patients (71 female and 47 male) with lower urinary tract symptoms were enrolled in the current study. The mean age (62±13) years old, 37.3% of patients presented with urgency as the main type of dysfunction. Diabetic cystopathy were fo

... Show More
Scopus (1)
Scopus Crossref
View Publication
Publication Date
Thu Jun 15 2023
Journal Name
Bionatura
Copper-to-Zinc Ratio as an Inflammatory Marker in Serum of Iraqi Patients with Axial Spondyloarthritis

Axial spondyloarthritis (axSpA) is a chronic rheumatic inflammatory disease affecting mainly the spine and sacroiliac joints. Since the copper-to-zinc ratio (Cu/Zn) indicates an inflammatory response, the change in ratio is expected to correlate with axSpA. This study compared levels of Cu/Zn in the serum of axSpA patients. Serum samples were obtained from 53 patients with axSpA divided according to biological treatment into cohorts A and B, and 28 healthy control as cohort C. Serum levels of Cu and Zn were determined first by a fully automated chemistry analyzer TC-Matrix Plus, then the ratio was obtained. The elevated serum Cu concentration means of cohort B (189.32 ± 13.808 µg/dL) compared to cohort A (168.85 ± 7.244 µg/dL) a

... Show More
Scopus (1)
Scopus Crossref
View Publication
Publication Date
Sat Oct 01 2022
Journal Name
The Egyptian Journal Of Hospital Medicine
Evaluation of Certain Physiological Biomarkers in Iraqi Endometrial Carcinoma Patients

Background: Endometrial Cancer (EC) is the malignant tumor originating from endometrium cell (lining of the uterus). EC incidence and mortality have increased in recent years. Routinely used methods for EC diagnosis and treatment are histopathological tissue culture after surgery and postoperative radiotherapy, however there is still not enough efficient treatment for recurrence or progression of this disease. So, there is a critical need for further EC identification by new biological ways for the prognostic diagnosis of it. Objective: This study aimed to look for ways by which could help in diagnosis of EC before the hysterectomy. Materials and Methods: 55 patients with EC and 57 healthy women were involved in this study (up to 45 years)

... Show More
Scopus Crossref
View Publication Preview PDF
Publication Date
Sun Sep 15 2024
Journal Name
Iraqi Journal Of Pharmaceutical Sciences( P-issn 1683 - 3597 E-issn 2521 - 3512)
Biomarkers of Oxidative Stress in Diabetic Microvascular Complications Review Article

Reactive oxygen species (ROS) are produced as a result of biochemical processes that are not in balance with the body's antioxidant defense mechanism. This metabolic dysfunction is referred to the oxidative stress (OS).  Metabolic dysfunction-associated diseases are affected by changes in the redox balance. It is now widely recognized that oxidative stress significantly affects diabetes mellitus (DM), particularly type 2 diabetes. The biochemical changes associated with  DM could  disturb the oxidative milieu, leading to several microvascular complications in diabetic patients. Thus, DM is a perfect disease to explore the harmful consequences of oxidative stress and how to treat it. Oxidative stress triggered by hyperglycemia is

... Show More
Scopus (2)
Scopus Crossref
View Publication
Publication Date
Mon Apr 23 2018
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Comparison Between Procalcitonin and Traditional Blood Biomarkers in Diagnosis of Sepsis in Iraqi Wounded Soldiers

      Early diagnosis of sepsis is a very critical matter especially for soldiers in battle field; on the other hand, Procalcitonin is a new promising biomarker for fast and accurate diagnosis of sepsis. The aim of this study is to investigate the ability of Procalcitonin (PCT) to indicate sepsis earlier than blood culture and other traditional biomarkers and then get use of this in early diagnosis of sepsis.Procalcitonin concentration was measured in 44 sera of Iraqi wounded soldiers who were admitted to GHAZI AL-HARIRI Hospital for surgery, using ELISA kit of BioRay/USA, along with blood culture and other infection biomarker like C-reactive protein, ESR, W.B.C. count. Six patients had elevated PCT and 3 of them

... Show More
Crossref
View Publication Preview PDF
Publication Date
Wed Jan 01 2020
Journal Name
Annals Of Tropical Medicine And Public Health
Scopus (1)
Crossref (1)
Scopus Crossref
View Publication
Publication Date
Wed Oct 12 2011
Journal Name
Journal Of Liquid Chromatography &amp; Related Technologies
RAPID DETERMINATION OF SPHINGANINE AND SPHINGOSINE IN URINE BY HIGH PERFORMANCE LIQUID CHROMATOGRAPHY USING MONOLITHIC COLUMN

A rapid high performance liquid chromatography method for the determination of sphinganine (Sa) and sphingosine (So) in urine samples by employing a silica-based monolithic column is described. The samples were first extracted using ethyl acetate and derivatized using ortho-phthaldialdehyde in the presence of 2-mercaptoethanol. C20 sphinganine was used as internal standard. Under the optimized conditions, separation was achieved using a mixture of methanol:water (93:7, v/v), column temperature at 30°C, flow rate of 1 mL min−1, and an injection volume of 10 μL. Good linearity was obtained for Sa and So over the concentration range 20–500 ng mL−1(correlation coefficients ≥0.9978). The detection limits were 0.45 ng mL−1 for Sa and

... Show More
Scopus Clarivate Crossref
View Publication
Publication Date
Sat Feb 09 2019
Journal Name
Iraqi Journal Of Laser
Primary Diagnosis of Abnormal Urine via Auto Fluorescence Process

The main objective of this study is to determine the suitable excitation wavelengths for
urine components reaching to select the suitable lasers to execute the auto fluorescence due to their
high intensities. The auto fluorescence was measured at 305, 325 and 350 nm excitation wavelengths
for eleven urine samples which were also analyzed by conventional methods (chemical and
microscopic examination). Data manipulation using Matlab package programming language showed
that urine sample with normal chemical and biological components have emission peaks which are
different from the infected urine samples. Despite the complexity of the composition of urine,
fluorescence maxima can be observed. Most likely, the peaks obser

... Show More
View Publication Preview PDF
Publication Date
Tue Dec 16 2008
Journal Name
Iraqi Journal Of Laser
Primary Diagnosis of Abnormal Urine via Auto Fluorescence Process

The main objective of this study is to determine the suitable excitation wavelengths for
urine components reaching to select the suitable lasers to execute the auto fluorescence due to their
high intensities. The auto fluorescence was measured at 305, 325 and 350 nm excitation wavelengths
for eleven urine samples which were also analyzed by conventional methods (chemical and
microscopic examination). Data manipulation using Matlab package programming language showed
that urine sample with normal chemical and biological components have emission peaks which are
different from the infected urine samples. Despite the complexity of the composition of urine,
fluorescence maxima can be observed. Most likely, the peaks obser

... Show More
View Publication Preview PDF
Publication Date
Wed Mar 10 2021
Journal Name
Baghdad Science Journal
Estimation of Bladder pressure by using poiseuilles equation

Equation Boizil used to Oatae approximate value of bladder pressure for 25 healthy people compared with Amqas the Alrotinahh ways used an indirect the catheter Bashaddam and found this method is cheap and harmless and easy

View Publication Preview PDF