Dyes are extensively water-soluble and toxic chemicals. The disposing of wastewater rich with such chemicals has severely impacted surface water quality (rivers and lakes). In the current study, an anionic dye, methyl orange, were extracted from wastewater fluids using bulk liquid membranes supplemented with an anionic carrier (Aliquat 336 (QCI)). Parameters including solvent type (carbon tetrachloride and chloroform), membrane stirring speed (100-250 rpm), mixing speed of both phases (50-100 rpm), The feed pH (2-12) and implemented temperature (35-60 °C) were thoroughly analyzed to determine the effect of such variables on extraction effectiveness. Furthermore, the effect of methyl orange (10-50 ppm) in the feed stage and NaOH (0.15-0.5 M) in the stripping stage concentrations were examined. It was found that high extraction efficiency (optimum operating conditions) for methyl orange of approximately 93% was reached through the membrane of a bulk liquid at 40 ppm initial concentration of feed; stirring speed of feed and stripping phases 75 rpm; stirring speed of membrane phase 200 rpm; 0.25 M NaOH concentration; carrier concentration 1wt%; feed pH of methyl orange 6.7, and 35˚C. Methyl orange kinetics were examined under the kinetic model of two irreversible first-order reactions under the best possible scenarios. The values of activation energy of J.mol−1 were 669.4 and 1930.5 for the extraction and stripping procedures. These values demonstrate that diffusion and not a chemical reaction dominates the transport process.
A new family of nematic liquid crystal dendrimers derived from 3,5-dihydroxybenzoic acid were synthesized. The synthesis of the dendrimers compounds shows the influence of the dendritic core on the mesomorphic properties. The liquid crystalline properties were studied by polarizing optical microscopy (POM) equipped with a hot stage, the structures of the synthesized compounds characterized using FTIR and 1HNMR spectroscopy.
We describe curved-mirror Fabry-Perot cavities with embedded silicon nitride membranes, fabricated using a monolithic surface-micromachining process. The presence of the suspended membranes was confirmed by confocal microscopy, and their properties were verified through optical studies and thermomechanical calibration of mechanical/vibrational noise spectra measured at room temperature and atmospheric pressure. The cavities exhibit reflectance-limited finesse (
A new compounds of 2,4-substituted-1,3- thiazole containing amines [I] and [II], Schiff bases [IV] and [V], amides [VI]-[X],esters [XI] - [XIII], thiazolidinones [XIV]-[XVIII] and 1,3-oxazepines [XIX]-[XXV] were Synthesized and characterized by melting points, FTIR spectroscopy, elemental analysis, 1HNMR,13CNMR, dept135and Mass spectroscopy. The liquid crystalline properties of the synthesized compounds were verified by using hot-stage polarizing optical microscopy (POM) and differential scanning calorimeter (DSC). The compound [I] was found to be nematic textures (N). The first series of this study [II]n display only enantiotropic nematic phase when n=1-5 while the compounds with n =6-8 display two mesophasese smectic C(SmC) and nematic ph
... Show MoreSixty samples of commercially available contact lens solutions were collected from students at the Pharmacy College/Baghdad University. The types of lenses used varied from medical to cosmetic. They were cultured to diagnose any microbial contamination within the solutions. Both used and unused solutions were subject for culturing. Thirty six (60%) used samples showed bacterial growth, fungal growth was absent. Pseudomonas aeruginosa accounts for the highest number of isolates (25%) followed by E. coli (21%), Staphylococcus epidermidis (6.6%), Pseudomonas fluorescence (5%) and Proteus mirabilis (1.6%) respectively. Only one (1) unused (sealed) sample showed growth of P. fluorescence.
... Show MoreThe chromatographic behaviour of liquid crystalline compounds benzylidene-p-aminobenzoic acid and 4-(p-methyl benzylidene)-p-aminobenzoic acid as stationary phases for the separation of dimethylphenol isomers was investigated. These isomers were analysed on benzylidene-p-aminobenzoic acid within a nematic range of 169-194 ◦C with a temperature interval of 5 ◦C. Better peak resolution was at a column temperature of 190 ◦C. The analysis was repeated on a 4-(p-methyl benzylidene)-p-aminobenzoic acid column at a nematic temperature of 256 ◦C, which represented the end of the nematic range, and gave the optimum peak resolution. It was found that isomer better separation was obtained at 20% loading for both liquid crystal materials. Other
... Show MoreThis paper deals with an analytical study of the flow of an incompressible generalized Burgers’ fluid (GBF) in an annular pipe. We discussed in this problem the flow induced by an impulsive pressure gradient and compare the results with flow due to a constant pressure gradient. Analytic solutions for velocity is earned by using discrete Laplace transform (DLT) of the sequential fractional derivatives (FD) and finite Hankel transform (FHT). The influences of different parameters are analyzed on a velocity distribution characteristics and a comparison between two cases is also presented, and discussed in details. Eventually, the figures are plotted to exhibit these effects.
In this work, laboratory experiments were carried out to verify direct contact membrane distillation system’s performance in highly saline water desalination. The study included the investigation of various operating conditions, like feed flow rate, temperature and concentration of NaCl solution and their impact on the permeation flux were discussed. 16 cm2 of a flat sheet membrane module with commercial poly-tetra-fluoroethylene (PTFE) membrane, which has 0.22 μm pore size, 96 µm thickness and 78% average porosity, was used. A high salt rejection factor was obtained greater than 99.9%, and the permeation flux up to 17.27 kg/m2.h was achieved at 65°C for hot feed side and 20°C for cold side stream.
This work deals with the preparation of a zeolite/polymer flat sheet membrane with hierarchical porosity and ion-exchange properties. The performance of the prepared membrane was examined by the removal of chromium ions from simulated wastewater. A NaY zeolite (crystal size of 745.8 nm) was prepared by conventional hydrothermal treatment and fabricated with polyethersulfone (15% PES) in dimethylformamide (DMF) to obtain an ion-exchange ultrafiltration membrane. The permeate flux was enhanced by increasing the zeolite content within the membrane texture indicating increasing the hydrophilicity of the prepared membranes and constructing a hierarchically porous system. A membrane contain
The study aims to investigate the effect of Al2O3 and Al additions to Nickel-base superalloys as a coating layer on oxidation resistance, and structural behavior of nickel superalloys such as IN 738 LC. Nickel-base superalloys are popular as base materials for hot components in industrial gas turbines such as blades due to their superior mechanical performance and high-temperature oxidation resistance, but the combustion gases' existence generates hot oxidation at high temperatures for long durations of time, resulting in corrosion of turbine blades which lead to massive economic losses. Turbine blades used in Iraqi electrical gas power stations require costly maintenance using traditional processes regularly. These blades are made
... Show MoreA simple reverse-phase high performance liquid chromatographic method for the simultaneous analysis (separation and quantification) of furosemide (FURO), carbamazepine (CARB), diazepam (DIAZ) and carvedilol (CARV) has been developed and validated. The method was carried out on a NUCLEODUR® 100-5 C18ec column (250 x 4.6 mm, i. d.5μm), with a mobile phase comprising of acetonitrile: deionized water (50: 50 v/v, pH adjusted to 3.6 ±0.05 with acetic acid) at a flow rate 1.5 mL.min-1 and the quantification was achieved at 226 nm. The retention times of FURO, CARB, DIAZ and CARV were found to be 1.90 min, 2.79 min, 5.39 min and 9.56 min respectively. The method was validated in terms of linearity, accuracy, precision, limit of detection and li
... Show More