Dyes are extensively water-soluble and toxic chemicals. The disposing of wastewater rich with such chemicals has severely impacted surface water quality (rivers and lakes). In the current study, an anionic dye, methyl orange, were extracted from wastewater fluids using bulk liquid membranes supplemented with an anionic carrier (Aliquat 336 (QCI)). Parameters including solvent type (carbon tetrachloride and chloroform), membrane stirring speed (100-250 rpm), mixing speed of both phases (50-100 rpm), The feed pH (2-12) and implemented temperature (35-60 °C) were thoroughly analyzed to determine the effect of such variables on extraction effectiveness. Furthermore, the effect of methyl orange (10-50 ppm) in the feed stage and NaOH (0.15-0.5 M) in the stripping stage concentrations were examined. It was found that high extraction efficiency (optimum operating conditions) for methyl orange of approximately 93% was reached through the membrane of a bulk liquid at 40 ppm initial concentration of feed; stirring speed of feed and stripping phases 75 rpm; stirring speed of membrane phase 200 rpm; 0.25 M NaOH concentration; carrier concentration 1wt%; feed pH of methyl orange 6.7, and 35˚C. Methyl orange kinetics were examined under the kinetic model of two irreversible first-order reactions under the best possible scenarios. The values of activation energy of J.mol−1 were 669.4 and 1930.5 for the extraction and stripping procedures. These values demonstrate that diffusion and not a chemical reaction dominates the transport process.
A simple, precise, rapid, and accurate reversed – phase high performance liquid chromatographic method has been developed for the determination of guaifenesin in pure from pharmaceutical formulations.andindustrial effluent. Chromatography was carried out on supelco L7 reversed- phase column (25cm × 4.6mm), 5 microns, using a mixture of methanol –acetonitrile-water: (80: 10 :10 v/v/v) as a mobile phase at a flow rate of 1.0 ml.min-1. Detection was performed at 254nm at ambient temperature. The retention time for guaifenesin was found 2.4 minutes. The calibration curve was linear (r= 0.9998) over a concentration range from 0.08 to 0.8mg/ml. Limit of detection (LOD) and limit of quantification ( LOQ) were found 6µg/ml and 18µg/ml res
... Show MoreA simple and rapid high performance liquid chromatographic with fluorescence detection method for the determination of the aflatoxin B1, B2, G1 and G2 in peanuts, rice and chilli was developed. The sample was extracted using acetonitrile:water (90:10, v/v%) and then purified by using ISOLUTE multimode solid phase extraction. After the pre-column derivatisation, the analytes were separated within 3.7 min using Chromolith performance RP-18e (100–4.6 mm) monolithic column. To assess the possible effects of endogenous components in the food items, matrix-matched calibration was used for the quantification and validation. The recoveries of aflatoxins that were spiked into food samples were 86.38–104.5% and RSDs were <4.4%. The method was
... Show MoreAbstract Background: The emptied sheep’s ovarian follicles recently used as a container for spermatozoa during cryopreservation, it was found a proper carrier to cryopreserving spermatozoa in vapor-dependent cryopreservation. The aim of this study was to evaluate the effect of two periods of exposure to liquid nitrogen (LN2)vapor on the parameter of spermatozoa during cryopreservation in this technique. Method: The study was conducted on 30 semen samples from patients with oligozoospermia diagnosed by semen analysis according to the standard criteria of World Health Orgnization (WHO) 2010. Sheep’s ovarian follicles obtained from local slaughterhouse and prepared by slicing the ovaries and evacuating the follicular fluid and oocyt
... Show MoreThe nonlinear optical properties response of nematic liquid crystal (6CHBT) and the impact of doping with two kinds of nanoparticles; Fe3O4 magnetic nanoparticles and SbSI ferroelectric nanoparticles have been studied using the non-linear dynamic method through z-scan measurement technique. This was achieved utilizing CW He-Ne laser. The pure LC and magnetic LC nanoparticle composite samples had a maximum absorption while the ferroelectric LC nanoparticle composite had a minimum absorption of the incident light. The nonlinear refractive index was positive for the pure LC and the rod-like ferronematic LC composite samples, while it was negative for the ferroelectric LC composite. The studying of the nonlinear optical
... Show MoreThe activity of the aqueous extract of Olea europaea was tested at concentrations of 8, 15 or 20 mg/kg of body weight on lipid profile in twenty female local rabbits. These animals were randomly divided into four groups (five animals in each group). Three groups were dosed orally with the concentrations mentioned above, while the last was administered with distilled water and considered as a control group. These animals were orally dosed by aqueous extract using a micropipette for 30 days. The results showed that there was a significant (P<0.05) decrease in cholesterol, triglycerides, low density lipoprotein (LDL-cholesterol), very low density lipoprotein (VLDL-cholesterol) concentrations and atherosclerosis index means for the three trea
... Show MoreObjective: The concentration-dependent nephroprotective effects of orally-administered aqueous green tea extract (AGTE) were studied. Materials and Methods: Forty rats of both sexes (weighing ٢٠٠-٢٥٠g) with various concentrations {٠.٦٢٥%, ١.٢٥% and ٢.٥% of aqueous green tea extract (AGTE)} as their main source of drinking fluid ٧ days before and ٥ days after administration of methotrexate (MTX). The parameters of oxidative stress, malondialdehyde (MDA) and reduced glutathione (GSH) were daily measured in kidney homogenate in addition to histopathological examinations after killing. Results: Analysis of data revealed significant amelioration of oxidative stress in groups of animals treated with different concentrations of AG
... Show MoreBackground: Background : Patients with non-rheumatic atrial fibrillation have high risk of thromboembolism especially ischemic stroke usually arising from left atrial appendage .Transoesophageal echocardiography provides useful information for risk stratification in these patients as it detects thrombus in the left atrial or left atrial appendage. Objective : This study was conducted at Al-Kadhimiya Teaching Hospital to assess the prevalence of left atrial chamber thrombi in patients with chronic non-rheumatic atrial fibrillation using transoesophageal echocardiography and its clinical significance as well as to verify the superiority of transoesophageal over transthoracic echocardiography in the detection of these abnormalities. Type of
... Show More