This study aims to investigate the adequacy of composite cellular beams with lightweight reinforced concrete deck slab as a structural unit for harmonic loaded buildings. The experimental program involved three fixed-ends supported beams throughout 2140 mm. Three concrete types were included: Normal Weight Concrete (NWC), Lightweight Aggregate Concrete (LWAC), and Lightweight Fiber Reinforced Aggregate Concrete (LWACF). The considered frequencies were (5, 10, 15, 20, 25, and 30) Hz. It was indicated that the harmonic load caused a significant influence on LWAC response (64% greater than NWC) and lattice cracks were observed, especially at 30 Hz. As for LWACF slab, no cracks appeared,
The nephrotoxicity induced by methotrexate is a severe condition that greatly affects its therapeutic potential and has a significant inflammatory component. Fimasartan is an angiotensin receptor blocker that offers organ-protective effects and may be useful in mitigating renal injury. The present study explored the anti-inflammatory potential of two doses of fimasartan against methotrexate-mediated nephrotoxicity. Albino rats were intraperitoneally administered a single methotrexate (20 mg/kg). Intraperitoneal treatment with fimasartan (5 or 10 mg/kg/day) was initiated on day two after methotrexate injection and continued for seven consecutive days. Methotrexate significantly increased serum urea, creatinine, and NGAL concentrations. It al
... Show MoreCaffeine (1,3,7-trimethylxanthine), which is the most widely consumed stimulant in the world, had been isolated and estimated gravimetrically in fifteen different commercial kinds of tea found in the Iraqi market.The kinds of tea were chosen according to their differences in the degree of fermentation and the method of processing i.e. black , gray and green . The isolated caffeine was identified by melting point, sublimation, TLC, chemical tests, UV , IR , HPLC and CHNO analysis. &nb
... Show MoreThis paper demonstrates an experimental and numerical study aimed at comparing the influence of openings of different configurations on the flexural behavior of reinforced concrete gable roof beams. The experimental program consisted of testing six simply supported gable beams subjected to mid-point concentrated load. The variable which has been investigated in this work was opening's configuration (quadrilateral or circular) with the same upper and lower chords depth. The results indicate improvement in the beams’ flexural behavior when circular openings were used compared with that of quadrilateral openings, represented by an increase in ultimate load capacity and a decrease in deflection at the service limit. Also, there was an
... Show MoreThis research presents an experimental investigation on the influence of metakaolin replacement percentage upon some properties of different concrete types. Three types of concrete were adopted (self- compacted concrete, high performance concrete and reactive powder concrete) all of high sulphate (SO3) percentage from the fine aggregate weight, 0.75%. Three percentages of metakaolin replacement were selected to be studied (5, 7 and 10) %. Three types of concrete properties (compressive, flexural and splitting tensile strength) were adopted to achieve better understanding for the influence of adding metakaolin.. The output results indicated that the percentage of metakaolin had a different level of positive effect on the compressive strength
... Show More