Preferred Language
Articles
/
_RZgTYsBVTCNdQwCAMik
Effect of Gas Mixing Ratio on Energy Band Gap of Mixed-Phase Titanium Dioxide Nanostructures Prepared by Reactive Magnetron Sputtering Technique
...Show More Authors

View Publication
Publication Date
Fri Jun 01 2018
Journal Name
Journal Of Engineering
Experimental Study of Optimum Chilled Water Distribution Configuration in Air Conditioning Terminal Unit Using RSM Technique
...Show More Authors

The distribution of chilled water flow rate in terminal unit is an important factor used to evaluate the performance of central air conditioning unit. A prototype of A/C unit has been made, which contains three terminal units with a complete set of accessories (3-way valve, 2-way valve, and sensors) to study the effect of the main parameters, such as total water flow rate and chilled water supply temperature with variable valve opening. In this work, 40 tests were carried out. These tests were in two groups, 20 test for 3-way valve case and 20 test for 2-way valve case. These tests were performed at three levels of valve opening, total water flow rate and water supply temperature according to the design matrices establis

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed May 01 2013
Journal Name
Journal Of Drugs In Dermatology (jdd)
Melanocytes Transplantation in Patients With Vitiligo Using Needling Micrografting Technique - JDDonline - Journal of Drugs in Dermatology
...Show More Authors

AbstractBACKGROUND: Some cases of vitiligo require melanocyte transplantation, but these surgical techniques have varying degrees of success. OBJECTIVES: To perform melanocytes transplantion in patients with vitiligo using a new needling micrografting technique. PATIENTS and METHODS: This interventional case study took place at the Department of Dermatology and Venereology at Baghdad Teaching Hospital from December 2010 to September 2011. Twelve patients with vitiligo were included. A split-thickness skin graft was taken from the normal area and cut into micropieces ranging from 0.1 mm to 0.3 mm in diameter. The recipient area was anesthetized, and the micrografts were then implanted into the dermis using the needling technique. The number

... Show More
View Publication
Publication Date
Wed Apr 19 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Separation and determination of poly aromatic hydrocarbons in vegetables samples in Baghdad city using HPLC Technique
...Show More Authors

The Reversed Phase High Performance Liquid Chromatography (RP-HPLC) has been used for the separation of Poly aromatic hydrocarbons(PAHs) by using column Reprosil 100 C 18 which was found to be a suitable one for this purpose. The result showed that using mobile phase of (Acetonitrile-water) Reversed Phase HPLC , flow rate of (1.2 ml/min) , column temperature (30CËš) and wave length of (254nm), give a complete separation with a good resolution . The total separation time was less than 20 min. The result of the study showed that the vegetables of Baghdad city were polluted by poly aromatic hydrocarbons(PAHs) in different places where samples taken because of drainage of the heavy water ,industrial trash and trash of oil colanders. -

... Show More
Publication Date
Thu Dec 28 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Determining the Concentrations of Elements in Tobacco Selected in Iraqi Markets Using X-Ray Fluorescence Technique
...Show More Authors

  X-rays fluorescence technology was used  to measure the concentrations of trace and toxic elements in tobacco smoke. One sample local and eight samples were imported selected from Iraqi markets. The results proved that tobaccos contain few concentrations of element (calcium, potassium, sodium, manganese, magnesium, chlorine, and sulfur), trace concentrations of element (aluminum, vanadium, iron, cobalt, nickel, copper and zinc), and toxic concentrations of element (arsenic, selenium, bromine, antimony, cadmium, mercury and lead). Results are proved the concentrations of elements of samples are lower levels with the other countries in few element like (calcium, potassium, sodium and manganese), while the other elements were hi

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Apr 19 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Separation and Determination of Poly Aromatic Hydrocarbons in Vegetables Samples in Baghdad City Using HPLC Technique
...Show More Authors

The Reversed  Phase High Performance Liquid  Chromatography (RP-HPLC) has been used for the separation of  Poly aromatic hydrocarbons(PAHs) by using column Reprosil 100 C 18 which  was found to be a suitable one for this purpose. The result showed that using mobile phase of (Acetonitrile-water) Reversed Phase HPLC , flow rate  of (1.2 ml/min) , column temperature (30CËš) and wave length of (254nm), give a complete separation with a good resolution . The total separation time was less than 20 min. The result of the study showed that the vegetables of Baghdad city were   polluted by poly aromatic hydrocarbons(PAHs) in different places where samples taken because of drainage  of the heavy water ,ind

... Show More
View Publication Preview PDF
Publication Date
Wed Sep 27 2023
Journal Name
Journal Of Optics
Studying the responsivity and detectivity of GO/PSi/n-Si photo detector via drop casting technique
...Show More Authors

View Publication
Scopus (3)
Crossref (3)
Scopus Clarivate Crossref
Publication Date
Sun Mar 01 2020
Journal Name
Plant Archives
Thermodynamic and kinetic analysis of Basic green-4 dye Removal from aqueous solutions using adsorption technique
...Show More Authors

In this work, a local sunflower husk (SFH) was used as a natural surface for removing Basic Green-4 (BG4) dye, as a watersoluble pollutant. The effect of initial concentration, contact time, the mass of surface of the dye with the SFH as well as the medium temperature was studied. The application of Langmuir, Freundlich isotherms on the collected data of the adsorption process found to harmonize to Freundlich equation more than that of Langmuir. However, the adsorbed mass of BG4 dye showed a direct increase with the increase of SFH mass and equilibrium was achieved within a 60min window. The interaction of BG4 with SFH surface was spontaneous and exothermic. The empirical kinetic outcomes at ambient temperatures were applied to pseudo 1st a

... Show More
Preview PDF
Scopus
Publication Date
Sat Oct 22 2022
Journal Name
Aro-the Scientific Journal Of Koya University
Classification of Different Shoulder Girdle Motions for Prosthesis Control Using a Time-Domain Feature Extraction Technique
...Show More Authors

Abstract—The upper limb amputation exerts a significant burden on the amputee, limiting their ability to perform everyday activities, and degrading their quality of life. Amputee patients’ quality of life can be improved if they have natural control over their prosthetic hands. Among the biological signals, most commonly used to predict upper limb motor intentions, surface electromyography (sEMG), and axial acceleration sensor signals are essential components of shoulder-level upper limb prosthetic hand control systems. In this work, a pattern recognition system is proposed to create a plan for categorizing high-level upper limb prostheses in seven various types of shoulder girdle motions. Thus, combining seven feature groups, w

... Show More
View Publication Preview PDF
Scopus (5)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Wed Sep 27 2023
Journal Name
Journal Of Optics
Studying the responsivity and detectivity of GO/PSi/n-Si photo detector via drop casting technique
...Show More Authors

View Publication
Scopus (3)
Crossref (3)
Scopus Clarivate Crossref
Publication Date
Fri Sep 30 2016
Journal Name
Al-khwarizmi Engineering Journal
Modeling the removal of Cadmium Ions from Aqueous Solutions onto Olive Pips Using Neural Network Technique
...Show More Authors

The uptake of Cd(II) ions from simulated wastewater onto olive pips was modeled using artificial neural network (ANN) which consisted of three layers. Based on 112 batch experiments, the effect of contact time (10-240 min), initial pH (2-6), initial concentration (25-250 mg/l), biosorbent dosage (0.05-2 g/100 ml), agitation speed (0-250 rpm) and temperature (20-60ºC) were studied. The maximum uptake (=92 %) of Cd(II) was achieved at optimum parameters of 60 min, 6, 50 mg/l, 1 g/100 ml, 250 rpm and 25ºC respectively.

Tangent sigmoid and linear transfer functions of ANN for hidden and output layers respectively with 7 neurons were sufficient to present good predictions for cadmium removal efficiency with coefficient of correlatio

... Show More
View Publication Preview PDF