Preferred Language
Articles
/
_RZRfYgBVTCNdQwCgHfz
K. wire fixation versus conservative treatment of closed displaced intra-articular calcaneal fractures
...Show More Authors

Background: Calcaneus is a spongy cancellous bone with rich blood supply , its fracture heals more rapidly providing no occurrence of infection and soft tissue injury around ,no gross malposition of fragments. The associated pain leads to a major impairment in life quality. The aim of treatment for calcaneal fractures is the decrease of pain and rebuilding of walking ability for patients with normal foot shape and the ability to wear normal foot wear. To reduce complications, a minimally invasive technique for the treatment of displaced intra-articular fractures of the calcaneus was preferred to use. The purpose of this study was to determine whether the closed reduction and percutaneous K. wire fixation of displaced intra-articular calcaneal fractures results in better functional outcome at a minimum one year follow up after the injury compared with those after non-operative management. Methods: One hundred and eleven displaced closed intra-articular calcaneal fracture in 105 patients (six were bilateral) were seen at the orthopedic department of Al-Kindy teaching hospital and Shaih Zaid hospital , only 45 cases included in this study and prospectively evaluated with an average follow-up time of minimum  of one year (1–3years follow-up). For radiographic evaluation, plain radiographs and CT scans were obtained. The Maryland Foot Score was used for clinical estimate. Sanders type II, III and IV fractures were diagnosed. Results: The incidence of subtalar arthritis was correlated with the severity of fracture. Böhler’s angle was restored in 70.1% (47 of 67) of the cases. The majority (77.7%) of patients were content with their treatment result. The rate of significant complications was 6.5%. Discussion: Percutaneous K. wire fixation of displaced intra-articular calcaneal fractures presented minimally invasive technique which showed comparable results with a low rate of serious complications and is a viable alternative for the treatment of intra-articular, dislocated calcaneal fractures. Conclusions: the functional results after K. wires fixation of displaced intra-articular calcaneal fractures were better than those after non-operative care.

Crossref
Preview PDF
Quick Preview PDF
Publication Date
Tue Dec 03 2013
Journal Name
Baghdad Science Journal
Satellite Images Unsupervised Classification Using Two Methods Fast Otsu and K-means
...Show More Authors

Publication Date
Wed Apr 28 2021
Journal Name
Journal Of Engineering
A Ultra-broadband Thin Metamaterial Absorber for Ku and K Bands Applications
...Show More Authors

In this paper, a design of the broadband thin metamaterial absorber (MMA) is presented. Compared with the previously reported metamaterial absorbers, the proposed structure provides a wide bandwidth with a compatible overall size. The designed absorber consists of a combination of octagon disk and split octagon resonator to provide a wide bandwidth over the Ku and K bands' frequency range. Cheap FR-4 material is chosen to be a substate of the proposed absorber with 1.6 thicknesses and 6.5×6.5 overall unit cell size. CST Studio Suite was used for the simulation of the proposed absorber. The proposed absorber provides a wide absorption bandwidth of 14.4 GHz over a frequency range of 12.8-27.5 GHz with more than %90 absorp

... Show More
View Publication Preview PDF
Crossref (4)
Crossref
Publication Date
Mon Mar 13 2017
Journal Name
Journal Of Baghdad College Of Dentistry
Gingival health condition and salivary physical properties among a group of patients with intermaxillary fixation in tow times intervals (Follow up study)
...Show More Authors

ABSTRACT Background: One of the methods used in the treatment of maxillofacial fracture is intermaxillary fixation(IMF), the most common type is the Erich arch bar with interdental wiring. This study was conducted to investigate the impact of intermaxillary fixation on gingival health condition among a group of patients with facial fracture in relation to salivary physical properties. Materials and methods: Thirty patients with an age range of (17-37) years old with facial fractures and indicated for IMF. Plaque index and gingival index (Loe, 1967) were used to assess both of them before application and after removal of IMF. Unstimulated saliva sample collection was carried out under standardized conditions according to Navazesh and Kum

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Dec 01 2023
Journal Name
Physical Chemistry Research
Thermophysical Study of Ethylene Glycol + H2O and Ethylene Glycol + (DMF/H2O) at 298.15 K
...Show More Authors

In this research, some thermophysical properties of ethylene glycol with water (H2O) and two solvent mixtures dimethylformamide/ water (DMF + H2O) were studied. The densities (ρ) and viscosities (η) of ethylene glycol in water and a mixed solvent dimethylformamide (DMF + H2O) were determined at 298.15 K, t and a range of concentrations from 0.1 to1.0 molar. The ρ and η values were subsequently used to calculate the thermodynamics of mixing including the apparent molar volume (ϕv), partial molar volume (ϕvo) at infinite dilution. The solute-solute interaction is presented by Sv results from the equation ∅_v=ϕ_v^o+S_v √m. The values of viscosity (B) coefficients and Falkenhagen coefficient(A) of the Jone-Dole equation and Gibbs fre

... Show More
Preview PDF
Publication Date
Mon Apr 01 2013
Journal Name
Ibn Al-haitham Journal For Pure And Applied Science
The Construction of (k, 3)-Arcs in PG (2, 9) by Using Geometrical Method
...Show More Authors

In this work, we construct projectively distinct (k,3)-arcs in the projective plane PG(2,9) by applying a geometrical method. The cubic curves have been been constructed by using the general equation of the cubic. We found that there are complete (13,3)-arcs, complete (15,3)-arcs and we found that the only (16,3)-arcs lead to maximum completeness

Publication Date
Sat Jul 22 2023
Journal Name
Journal Of Engineering
Experimental Investigation into the Heat and Mass Transfer in an Indirect Contact Closed Circuit Cooling Tower
...Show More Authors

The heat and mass transfer coefficients of the indirect contact closed circuit cooling tower, ICCCCT, were investigated experimentally. Different experiments were conducted involving the controlling parameters such as air velocity, spray water to air mass flow rate ratio, spray water flow rate, ambient air wet bulb temperature and the provided heat load to investigate their effects on the performance of the ICCCCT. Also the effect of using packing on the performance of the ICCCCT was investigated. It was noticed that these parameters affect the tower performance and the use of packing materials is a good approach to enhance the performance for different operational conditions. Correlations for mass and heat transfer coefficients are pres

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Jun 26 2018
Journal Name
Oriental Journal Of Chemistry
Excess Molar Quantities of Binary Mixture of Dipropyl amine with Aliphatic Alcohols at 298.15 K
...Show More Authors

Refractive indices (nD), viscosities (η) and densities (r) were deliberated for the binary mixtures created by dipropyl amine with 1-octanol, 1-heptanol, 1-hexanol, 1-pentanol and tert-pentyl alcohol at temperature 298.15 K over the perfect installation extent. The function of Redlich-Kister were used to calculate and renovated of the refractive index deviations (∆nD), viscosity deviations (ηE), excess molar Gibbs free energy (∆G*E) and excess molar volumes(Vm E). The standard errors and coefficients were respected by this function. The values of ∆nD, ηE, Vm E and ∆G*E were plotted against mole fraction of dipropyl amine. In all cases the obtained ηE, ∆G*E, Vm E and ∆nD values were negative at 298.15K. Effect of carbon atoms

... Show More
Publication Date
Tue Jul 31 2018
Journal Name
Oriental Journal Of Chemistry
Excess Molar Quantities of Binary Mixture of Dipropyl amine with Aliphatic Alcohols at 298.15 K
...Show More Authors

Refractive indices (nD), viscosities (η) and densities (ρ) were deliberated for the binary mixtures created by dipropyl amine with 1-octanol, 1-heptanol, 1-hexanol, 1-pentanol and tert-pentyl alcohol at temperature 298.15 K over the perfect installation extent. The function of Redlich-Kister were used to calculate and renovated of the refractive index deviations (∆nD), viscosity deviations (ηE), excess molar Gibbs free energy (∆G*E) and excess molar volumes (VmE) The standard errors and coefficients were respected by this function. The values of ∆nD, ηE, VmE and ∆G*E were plotted against mole fraction of dipropyl amine. In all cases the obtained ηE, ∆G*E, VmE and ∆nD values were negative at 298.15K. Effect of carbo

... Show More
View Publication
Scopus (10)
Crossref (5)
Scopus Clarivate Crossref
Publication Date
Wed Jun 13 2018
Journal Name
Rasayan Journal Of Chemistry
Novel Thermodynamic Properties of Binary Mixtures of Tetrahydrofurfuryl Alcohol wiyh some Alcohols At 298.15 K
...Show More Authors

Publication Date
Mon Mar 08 2021
Journal Name
Baghdad Science Journal
CALCULATION OF EXCESS MOLAR VOL-UMES OF SOME TERNARY LIQUID MIX-TURES AT 303.15 K
...Show More Authors

Excess molar volumes of five ternary mixtures of 2- methoxy ethanol(1) +butyl acetate(2)+benzene(3), +toluene(3), +chlorobenzene(3), +bromobenzene(3), and +nitrobenzene(3) have been measured at 303.15K. The excess molar volume exhibited positive deviation over the entire range of composition in the systems 2-methoxy ethanol(1)+ butyl acetate(2)+ benzene(3),+toluene(3) and sigmoid behavior in the case of the remaining systems. Flory's statistical theory have been extended to predict the excess molar volumes of the five ternary mixtures at 303.15 k over a wide range of composition . An excellent agreement has been found between the experimental and theoretical excess molar volumes , both in magnitude and sign .

View Publication Preview PDF