Purpose: Despite the high clinical accuracy of dynamic navigation, inherent sources of error exist. The purpose of this study was to improve the accuracy of dynamic navigated surgical procedures in the edentulous maxilla by identifying the optimal configuration of intra-oral points that results in the lowest possible registration error for direct clinical implementation. Materials and methods: Six different 4-area configurations were tested by 3 operators against positive and negative controls (8-areas and 3-areas, respectively) using a skull model. The two dynamic navigation systems (X-Guide® and NaviDent®) and the two registration methods (bone surface tracing and fiducial markers) produced four registration groups. The accuracy of the registration was checked at the frontal process of the zygoma. Intra- and inter- operator reliability for each registration group were reported. Multiple comparisons were conducted to find the best configuration with the minimum registration error. Results: Ranking revealed one configuration in the tracing groups (Conf.3) and two configurations in the fiducial groups (Conf.3 and Conf.5) that had the best accuracy. When the inferior surfaces of the zygomatic buttress were excluded, fiducial registration produced better accuracy with both systems (p 0.006 and <0.0001). However, tracing 1 cm areas at these surfaces bilaterally resulted in similar registration accuracy as placing fiducial markers there (p 0.430 and 0.237). NaviDent® performed generally better (p 0.049, 0.001 and 0.002) albeit having a wider margin of uncertainty in the obtained values. Changing the distribution of the 4 tracing areas or fiducial markers had a less pronounced effect with X-Guide® than with the NaviDent® system. Conclusion: For edentulous maxillary surgeries, 4 fiducial markers placed according to configuration 3 or 5 result in the lowest registration error. Where implants are being placed bilaterally, an additional 2 sites may reduce the error further. For bilateral zygomatic implant placement, it is optimal to place 2 fiducials on the inferior surfaces of the maxillary tuberosities, other 2 on their buccal surfaces, and 2 on the anterior labial surface of the alveolar bone. Utilising the inferior zygomatic buttress is recommended over the inferior maxillary tuberosities in other types of maxillary surgeries.
Electronic University Library: Reality and Ambition Case Study Central Library of Baghdad University
The preparation of activated carbon (AC) from date stones by using microwave assisted K2CO3 activation was investigated in this paper. The influence of radiation time, radiation power, and impregnation ratio on the yield and methylene blue (MB) uptake of such carbon were studied. Based on Box-Wilson central composite design, two second order polynomial models were developed to correlate the process variables to the two responses. From the analysis of variance the significant variables on each response were identified. Optimum coditions of 8 min radiation time, 660 W radiation power and 1.5 g/g impregnation ratio gave 460.123 mg/g MB uptake and 19.99 % yield. The characteristics of the AC were examined by pore structure analysis, and scan
... Show MorePathogenic microorganisms are becoming more and more resistant to antimicrobial agents. So the synthesis of new antimicrobial agents is very important. In this work, new 5-fluoroisatin-chalcone conjugates 5(a–g) were synthesized based on previous research that showed the modifications of the isatin moiety led to the synthesis of many derivatives that have antimicrobial activity. 4-aminoacetophenone reacts with 5-fluoroisatin to form Schiff base (3), which in turn reacts with two different groups of aromatic (carbocyclic and heterocyclic) aldehydes 4(a–g) separately to form the final compounds 5(a–g). Proton-nuclear magnetic resonance (¹H-NMR) and Fourier-transform infrared (FT-IR) spectroscopy were used to confirm the chemic
... Show Moremenopause is the most common cause of accelerated bone loss in women. Omentin-1 is secreted by the visceral adipose tissue and it isdonated in the regulation of bone metabolism in postmenopausal women which is related with decreased bone mineral density. The current study aims to investigate the role of serum omentin-1and some bone metabolism markers in osteoporosis among postmenopausal Iraqi women. This study was performedin the Rheumatology and Rehabilitation Unit, Baghdad Teaching Hospital/ Baghdad medical city, during the period from November 2019 to July 2020 with a total of 60 postmenopausal women(30 with osteoporosis and 30 without osteoporosis), their ages ranged from 52 to 62 years. They were compared with 30 healthy premenopausal
... Show MoreAbstract. In this work, Bi2O3 was deposited as a thin film of different thickness (400, 500, and 600 ±20 nm) by using thermal oxidation at 573 K with ambient oxygen of evaporated bismuth (Bi) thin films in a vacuum on glass substrate and on Si wafer to produce n-Bi2O3/p-Si heterojunction. The effect of thickness on the structural, electrical, surface and optical properties of Bi2O3 thin films was studied. XRD analysis reveals that all the as deposited Bi2O3 films show polycrystalline tetragonal structure, with preferential orientation in the (201) direction, without any change in structure due to increase of film thickness. AFM and SEM images are used to investigate the influences of film thickness on surface properties. The optical measur
... Show MoreAniline and its derivatives are common contaminants in various wastewaters and represent a serious worry for societies health and a challenge to ecologists due to their dangers effects on to the human health.
ZSM-5 zeolite was prepared from locally available materials (kaolin and rice husk) for adsorption of aniline from synthetic wastewater. Characterization of the prepared zsm-5, kinetics and thermodynamic of the adsorption process were investigated.
The characterization results of the prepared zsm-5 zeolite showed that the surface area was 270.1 m2/g and pore volume 0.21828 cm3/g. The silica to alumina ratio (Si/Al) was 166. 47 and the sodium content was 11 wt. %. The atomic force microscope (AFM)
... Show MoreAbstract
The aim of this paper is to investigate and discuss the mechanisms of corrosion of epoxy coatings used for potable water tanks. Two distinct types of Jotun epoxy coatings: Tankguard 412 contained polyamine cured epoxy and Penguard HB contained polyamide cured epoxy, were tested and studied using the electrochemical impedance spectroscopic (EIS) method. The porosity of epoxy coatings was determined using EIS method. The obtained results showed that the two epoxy coatings have excellent behavior when applied and tested in potable water of Basrah city. Polyamine is more resistance to water corrosion compared to polyamide curing epoxy and has high impedance values. Microscopic inspection after te
... Show MoreBackground The traditional management of appendicular mass is an initial conservative treatment followed by interval appendectomy. Recently interval appendicectomy has been questioned.
Objective: The purpose of this study was to clarify the need and the role of interval appendicectomy after successful initial conservative treatment.
Method: This is a prospective study conducted in a major hospital in Basra from April 2006 to Septemper2010, included 65 patients with appendicular mass which subsequently proved postinflammmatory (phlegmonous) changes of the appendix were treated conservatively.
Results: Routine interval appendicectomy was not performed and needed after successful treatment in the majority of the patients (84.6%). F