Preferred Language
Articles
/
ZxbmQYcBVTCNdQwCHj6O
A Three-Dimensional Finite Element Analysis for Overdenture Attachments Supported by Teeth and/or Mini Dental Implants
...Show More Authors

Crossref
View Publication
Publication Date
Mon Oct 01 2018
Journal Name
Iraqi Journal Of Physics
A three-stage blumlein-circuit to generate transversely excited atmospheric nitrogen laser by using three spark gaps
...Show More Authors

In this research constructed N2 laser system by use developed method of electric discharge. In this method used four step of electric discharge by using four capacitors, three spark gaps, high tension power supply varying in range from 12kV to 24 kV and three resistors, this method called three stage blumlein circuit. The breakdown time delay of these parallel spark gaps cement strong ultraviolet preionization in the laser channel, thus the result of these amendments the laser output is many doubled and is more increasing than that obtained using the one and two stage blumlein circuits. This system has been designed and operated to give pulse laser with wavelength at 337.1 nm. This laser system can operate without mirrors and optical res

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Dec 15 2019
Journal Name
Journal Of Baghdad College Of Dentistry
Evaluation of Crestal Bone Resorption around Dental Implants in Flapped and Flapless Surgical Techniques Depending on Cone Beam CT Scan (Comparative Study)
...Show More Authors

Background: The long term survival of dental implants is evaluated by the amount of crestal bone loss around the implants. Some initial loss of bone around dental implants is generally expected. There is reason to believe that reflecting a mucoperiosteal flap promotes crestal bone loss in the initial phase after an implant has been inserted. The surgical placement of a dental implant fixture is constantly changing and in recent years, there has been some interest in developing techniques that minimize the invasive nature of the procedure, with flapless implant surgery being advocated. The purpose of this study was to compare the radiographic level of the peri- implant bone after implant placement between traditional flapped surgery and f

... Show More
View Publication Preview PDF
Scopus (1)
Scopus Crossref
Publication Date
Sat Jul 31 2021
Journal Name
Iraqi Journal Of Science
Stability Analysis and Assortment of Exact Traveling Wave Solutions for the (2+1)-Dimensional Boiti-Leon-Pempinelli System
...Show More Authors

     In this research, the Boiti–Leon–Pempinelli (BLP) system was used to understand the physical meaning of exact and solitary traveling wave solutions. To establish modern exact results, considered. In addition, the results obtained were compared with those obtained by using other existing methods, such as the standard hyperbolic tanh function method, and the stability analysis for the results was discussed.

View Publication Preview PDF
Scopus (5)
Scopus Crossref
Publication Date
Fri Jun 24 2022
Journal Name
Iraqi Journal Of Science
Stresses and Displacements Analyses around Tunnel Opening Under Water Body Using Finite Element Method (FEM) in Baghdad City/Middle of Iraq
...Show More Authors

In this study, the stresses and displacement around a tunnel opening under water body in Baghdad city, middle of Iraq, during excavation and lining are discussed. For this purpose, the finite element method (FEM) was adopted as an effective approach to analyze the problem using (SIGMA/W) program. The research includes the study of the behavior of soil due to excavation of a tunnel by calculating the displacements and stresses in three positions of the tunnel (crown, wall, and invert) during the various stages of construction. The surface settlement is also studied. The finite element analyses were carried out Using (Elastic- plastic) and (linear elastic) models for the soil and the concrete liner respectively.

View Publication Preview PDF
Publication Date
Sat Feb 01 2025
Journal Name
Journal Of Baghdad College Of Dentistry
The effect of nutritional status on mesiodistal and bucco/ lingual or palatal diameters of permanent teeth among fifteen years old students
...Show More Authors

Background: Malnutrition during human growth affects the size of the tissues at different stages of life, body proportions, body chemistry, as well as quality and texture of tissues. Teeth are particularly sensitive to malnutrition. Malnutrition may affect odontometric measurement involving tooth size dimensions. The aim of this study was to estimate the effect of nutrition on teeth size dimension measurements among students aged 15 years old. Materials and methods: This study was conducted among malnourished group in comparison to well-nourished group matching with age and gender. The present study included 167 students aged 15 years (83 malnourished and 84 well-nourished). The assessment of nutritional status was done by using body mass

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat Feb 01 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Biomechanical evaluation of porous titanium implants (CpTi) fabricated by powder technology
...Show More Authors

Background: It may be an important prospective clinical use of manufacturing of porous implant for clinical situations, such as cases of limitation in bone height, low bone density .The small segment of porous implant an effective osseointegration allows increasing in contact area provided for small segmented porous provided by its surface configuration. This study was done to Fabricate porous titanium implants by powder technology, as well as the observation of removal torque values of porous titanium implants compared to smooth titanium implants. Materials and methods: Twenty porous titanium implants (3.2mm in diameter and 8mm in length) were manufactured by powder technology using commercially pure titanium powder of ≤75um part

... Show More
View Publication Preview PDF
Publication Date
Fri Sep 01 2017
Journal Name
International Journal Of Science And Research
Analysis of Correlation between Mesiodistal width of the Maxillary and Mandibular Anterior and Posterior Teeth for Both Genders in Iraqi Population
...Show More Authors

Abstract: Choosing suitable artificial teeth for partially edentulous patients and arranging these teeth in a way to look natural is difficult. An important factor in dentures construction is the mesiodistal width of anterior teeth, because a denture would not appearance natural if artificial teeth are of incorrect size. While for a successful orthodontic treatment, mesiodeistal width of teeth is important for space analysis and for establishing proper occlusion. The aim of this study is to determine the correlation between the average mesiodistal width of anterior and posterior teeth in male and female Iraqi population. 40 Iraqi subjects with normal occlusion participated in this study. Mesiodistal measurement of all teeth was carried out

... Show More
View Publication Preview PDF
Publication Date
Sat Dec 30 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
A New Biological System For Detecting Environmetal Carcinogens And /Or Mutagenes And Their Adversary
...Show More Authors

A  new  test  system  for  detecting  environment  carcinogenes and/or  mutagenes  and  their  adversary  It  has  been  induced.  One hundred and fifty   mutants   were isolated from   the basidiomycete fungus Coprinus cinereus   which were   resistant to guanine analogue S- az.aguanine .All the spontaneous and induced with UV light origin mutants were isolated from the wild type strains Bc9/6.6 and  Hd5.5

.These mutants were te ted on selective medium containing  different

concentrations of the analogue and also to their ability to usc purine bases and their degredated &nbs

... Show More
View Publication Preview PDF
Publication Date
Sat Aug 25 2018
Journal Name
Water
Minimizing the Principle Stresses of Powerhoused Rock-Fill Dams Using Control Turbine Running Units: Application of Finite Element Method
...Show More Authors

This study focuses on improving the safety of embankment dams by considering the effects of vibration due to powerhouse operation on the dam body. The study contains two main parts. In the first part, ANSYS-CFX is used to create the three-dimensional (3D) Finite Volume (FV) model of one vertical Francis turbine unit. The 3D model is run by considering various reservoir conditions and the dimensions of units. The Re-Normalization Group (RNG) k-ε turbulence model is employed, and the physical properties of water and the flow characteristics are defined in the turbine model. In the second phases, a 3D finite element (FE) numerical model for a rock-fill dam is created by using ANSYS®, considering the dam connection with its powerhouse

... Show More
View Publication
Scopus (8)
Crossref (8)
Scopus Clarivate Crossref
Publication Date
Tue Nov 01 2022
Journal Name
Journal Of Engineering
Finite Element Modeling of One-Way Recycled Aggregate Concrete Slabs Strengthened using Near-Surface Mounted CFRPs under Repeated Loading
...Show More Authors

This study offers numerical simulation results using the ABAQUS/CAE version 2019 finite element computer application to examine the performance, and residual strength of eight recycle aggregate RC one-way slabs. Six strengthened by NSM CFRP plates were presented to study the impact of several parameters on their structural behavior. The experimental results of four selected slabs under monotonic load, plus one slab under repeated load, were validated numerically. Then the numerical analysis was extended to different parameters investigation, such as the impact of added CFRP length on ultimate load capacity and load-deflection response and the impact of concrete compressive strength value on the structural performance of

... Show More
View Publication Preview PDF
Crossref (1)
Crossref