Preferred Language
Articles
/
ZhhCe5UBVTCNdQwCoC6n
Digital Evaluation of Cuspal Deflection of Endodontically Treated Teeth Restored with Resin Composite and Different Fiber Formulations
...Show More Authors

Background: This study evaluated the influence of different fiber formulations incorporation in resin composite on cuspal deflection (CD) of endodontically-treated teeth with mesio-occluso-distal (MOD) cavities. Materials and Methods: Thirty-two freshly extracted maxillary premolar teeth received MOD cavity preparation followed by endodontic treatment using single cone obturation technique, and divided into: Group I: direct composite resin only using a centripetal technique, Group II: direct composite resin with short fiber-reinforced composite (everX Flow), Group III: direct composite resin with leno wave ultra-high molecular weight polyethylene (LWUHMWPE) fibers placed on the cavity floor, and Group IV: direct composite resin with LWUHMWPE fibers placed circumferentially around the cavity walls (wallpapering technique). The CD was measured using a novel digital evaluation method, whereby each tooth was scanned by a desktop scanner (Medit T710) at three different time intervals: before and after cavity preparation, and after restoration. The intercuspal distance (ICD) was measured digitally in μm at each interval using Medit compare metrology software, followed by measurement of the CD by subtracting the ICD after cavity preparation; and after restoration from the before preparation one to obtain the “after cavity preparation CD1” and “the after restoration CD2”, respectively. The data were analyzed using one-way ANOVA and Tukey HSD tests at a significance level of 0.05. Results: The highest CD was recorded in Group I with statistically significant differences with all other groups (P<0.05). No statistically significant differences were found between the other groups (Groups II, III, and IV) (P>0.05). Conclusions: There was an inward deflection of the cusps in all groups following cavity preparation and restoration as elicited by the negative CD1 and CD2 values. The incorporation of fibers, regardless of their type or orientation, resulted in a significant reduction in CD of endodontically treated premolar teeth as compared with those restored with resin composite alone.

Preview PDF
Quick Preview PDF
Publication Date
Sat Mar 23 2024
Journal Name
Journal Of Optics
Tapered single-mode no-core optical fiber sensor coated with layer gold for hemoglobin sensing
...Show More Authors

The present work focuses on the experimental implementation of one of the fiber optical sensors, the optical glass fiber built on surface Plasmon resonance. A type of optical glass fiber was used in this work, single-mode no-core fiber with pre-tapering diameter: (125.1 μm) and (125.3 μm), respectively. The taper method can be tested by measuring the output power of the optical fiber before and after chemical etching to show the difference in cladding diameter due to the effect of hydrofluoric acid with increasing time for the taper process. The optical glass fiber sensor can be fabricated using the taper method to reduce the cladding diameter of the fibers to (83.12 µm, 64.37 µm, and 52.45 µm) for single-mode fibers using Hydrofluoric

... Show More
View Publication Preview PDF
Scopus (4)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Mon Dec 20 2021
Journal Name
Baghdad Science Journal
Dosimetric Verification of Gamma Passing Rate for Head and Neck Cases Treated with Intensity Modulated Radiation Therapy (IMRT) Treatment Planning Technique
...Show More Authors

Each Intensity Modulated Radiation Therapy (IMRT) plan needs to be tested and verified before any treatment to check its quality. Octavius 4D-1500 phantom detector is a modern and qualified device for quality assurance procedure. This study aims to compare the common dosimetric criteria 3%/3 mm with 2%/2 mm for H&N plans for the IMRT technique. Twenty-five patients with head and neck (H&N) tumor were with 6MV x-ray photon beam using Monaco 5.1 treatment planning software and exported to Elekta synergy linear accelerator then tested for pretreatment verification study using Octavius 4D-1500 phantom detector. The difference between planned and measured dose were assessed by using local and global gamma index (GI) analysis method at

... Show More
View Publication Preview PDF
Scopus (4)
Scopus Clarivate Crossref
Publication Date
Sat Mar 26 2022
Journal Name
Neuroquantology
Efficiency Evaluation of Optical System Includes Different Stop Apertures When Using Relative Moving Factor
...Show More Authors

In this work, optical system with different aperture shapes (circular, square, elliptical and triangle aperture) has been used for efficiency evaluation when the system involved moving factor in ideal case (aberration free). The optical system evaluate far moving object, therefore the image forming at image plane due to point spread function (image formula of incoherently illuminated point object). A mathematical treatment has been used to getting results by Gaussian numerical calculations method. The results show priority of circular aperture when optical system that submits of moving factor.

View Publication
Crossref (2)
Crossref
Publication Date
Wed Mar 29 2017
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Bioequivalence of Two Formulations of Amoxicillin in Human Healthy Volunteers on (HPLC) Technique
...Show More Authors

Amoxicillin is commercially available in the form of capsules and tablets containing 250mg or 500mg for oral administration. It is also available in the form of suspension containing "25mg/ml” . Amoxicillin is presently used as the most common antibiotics .Ten healthy Human volunteers were characterized respected to their pharmacokinetic and bioavailability of two formulations of Amoxicillin from two sources of  industrial companies  after a single dose administration was given orally. A procedure is described for determination the concentration levels of Amoxicillin in human plasma of healthy volunteers using high performance liquid chromatography (HPLC) with reversed-phase isocratic column at low wave length of UV-visib

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Mon Jul 30 2018
Journal Name
Civil Engineering Journal
Performance of Post-Fire Composite Prestressed Concrete Beam Topped with Reinforced Concrete Flange
...Show More Authors

The performance of composite prestressed concrete beam topped with reinforced concrete flange structures in fire depends upon several factors, including the change in properties of the two different materials due to fire exposure and temperature distribution within the composition of the composite members of the structure. The present experimental work included casting of 12 identical simply supported prestressed concrete beams grouped into 3 categories, depending on the strength of the top reinforced concrete deck slab (20, 30, and 40 MPa). They were connected together by using shear connector reinforcements. To simulate the real practical fire disasters, 3 composite prestressed concrete beams from each group were exposed to high t

... Show More
View Publication Preview PDF
Crossref (2)
Clarivate Crossref
Publication Date
Fri Nov 29 2019
Journal Name
Iraqi Journal Of Physics
Gas Sensing of (SnO2)1-x(ZnO)x Composite Associating with Electrical Properties
...Show More Authors

Abstract

Semiconductor-based gas sensors were prepared, that use n-type tin oxide (SnO2) and  tin oxide: zinc oxide composite (SnO2)1-x(ZnO)x at different x ratios using pulse laser deposition at room temperature. The prepared thin films were examined to reach the optimum conditions for gas sensing applications, namely X-ray diffraction, Hall effect measurements, and direct current conductivity. It was found that the optimum crystallinity and maximum electron density, corresponding to the minimum charge carrier mobility, appeared at 10% ZnO ratio. This ratio appeared has the optimum NO2 gas sensitivity for 5% gas concentration at 300 °C working temperat

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Mon Nov 01 2010
Journal Name
Iraqi Journal Of Physics
The Effect of metals as Additives on Thermal conductivity of Epoxy Resin
...Show More Authors

A hand lay-up method was used to prepare Epoxy/ metal composites. Epoxy resin (EP) was used as a matrix with metal particles (Al, Cu, and Fe) as fillers.
The preparation method includes preparing square panels of composites with different weight percentage of fillers (10, 20, 30, 40, and 50%). Standard specimens (88mm in diameter) for thermal conductivity tests were prepared to measure thermal conductivity kexp.The result of experimental thermal conductivity kexp, for EP/metal composites show that, kexp increase with increasing weight percentage, For EP/ Al and EP/Cu composites, and it have have maximum values of 0.33 and 0.35 W/m.K, respectively. While kexp for EP/ Fe composite show slight increase with maximum value of 0.186 W/m.K.

... Show More
View Publication Preview PDF
Publication Date
Sat Oct 01 2011
Journal Name
Iraqi Journal Of Physics
The Effect of metals as additives on adhesion properties of epoxy resin
...Show More Authors

EP/ metal composites were prepared as adhesives between two steel rods. Epoxy resin (EP) was used as a matrix with metal as fillers (Al, Cu, Fe,).
The preparation method for tensile adhesion tests includes two steel rods with adhesive composites between the rods to measure adhesion strength Sad and adhesion toughness Gad.
Results of tensile adhesion tests show that EP/ metals composite have maximum strength Sad for certain weight percentage of metals 2.95 and 9MPa at 10% for EP/Al and EP/Cu composite and 8.2MPa at 40% for EP/Fe composites

View Publication Preview PDF
Publication Date
Fri Sep 30 2016
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
A Morphological Study of Alumina Hollow Fiber Membrane
...Show More Authors

Morphologies of ceramic hollow fiber membranes prepared by a combined phase-inversion and sintering method were studied. The organic binder spinning solution containing suspended Al₂O₃ powders was spun to a hollow fiber precursor, which was then sintered at elevated temperatures( 300 ˚C, 1400 ˚C, 25 ˚C) in order to obtain the Al₂O₃ hollow fiber membranes. The spinning solution consisted of polyether sulfone (PES), N-methyl-2-pyrrolidone (NMP), which were used as polymer binder, solvent, respectively. The prepared Al₂O₃ hollow fiber membranes were characterized by a scanning electron microscope (SEM). It is believed that finger-like void formation in asymmetric ceramic membranes is initiated by hydrodynamically unstable vis

... Show More
View Publication Preview PDF
Publication Date
Mon Feb 16 2026
Journal Name
Journal Of Baghdad College Of Dentistry
Evaluation of the stress concentration of different incisal ridge preparations of porcelain veneers (Finite element analysis)
...Show More Authors

Background: Porcelain veneers are under a great deal of stress which may lead to clinical failure as fracture or dettachment. This study examined whether different finishing lines and lingual shoulder preparations in the incisal area of the maxillary central incisor affect the bond of the porcelain veneers. Materials and methods: A two- dimensional finite element model was made. Location and magnitude of maximum Von Mises stresses were calculated in porcelain veneer. Six types of preparations were drawn as:incisal overlap of 0.5mm, 1mm and 1.5mm depth and lingual shoulder, and incisal overlap of 0.5mm, 1mm and 1.5mm depth without shoulder preparation. Results: Stress formation is maximum in the incisal edge region. All the lingual shoulder

... Show More
View Publication Preview PDF