Background: Tumor associated tissue eosinophilia (TATE) has been described in a variety of neoplasms. In regard to squamous cell carcinoma, some studies worldwide done to assess stromal eosinophilia in oral and cervical squamous cell carcinoma. The objectives of this study is to evaluate the association of stromal eosinophilic infiltration of cutaneous squamous cell carcinoma and to detect the significance of this association. Aim of the study The aim of our study is to establish the relationship between the degree of stromal eosinophilia and the level of invasion and the histological grade in cutaneous squamous cell carcinoma. Methods: In this retrospective study done at the histopathology department of al Wasity teaching hospital for orthopedic and plastic surgery in Baghdad, all paraffin embedded blocks for excisional biopsies diagnosed as primary cutaneous squamous cell carcinoma from December 2015 to January 2017 were retrieved. Incisional biopsies and those with margin positive tumor cells were excluded. After a careful evaluation for histological grading and assessment of level of invasion according to an established histological criteria , the assessment of tissue eosinophils was done by three pathologist through counting eosinophils in tumor stroma in 10 high power field using a light microscope and categorized as none (0,),low (1-4),medium (5-19)and high (more than 20). Results : of 56 cases of primary cutaneous squamous cell carcinoma 48(85.7%) cases were conventional .The mean age was 43.14 ± 1.76 .Regarding conventional squamous cell carcinoma ,of 48 cases 30(62.5) were well differentiated,16(33.3%) had clarck level III,18(37.5%) had clarck level IV and 14(29.1%) had Clark level V .There is a significant statistical relationship between histological grading of tissue eosinophilia and level of invasion with p value 0.044 and a non-significant relationship with degree of differentiation. Conclusion :The majority of cutaneous squamous cell carcinomas were conventional well differentiated with a mean age in the fifth decade of life ,a male predominance and often had a degree of stromal eosinophilia that is strongly associated with the level of invasion .Thus more Intense tissue eosinophilia is correlated with a higher level of stromal invasion. The significance of such an association should be regarded as either a potential predictive tool for stromal invasion in small incisional biopsy or as a prognostic indicator that could be included in the pathology report for conventional squamous cell carcinoma
The study involved preparing a new compound by combining Schiff bases generated from compounds for antipyrine, including lanthanide ions (lanthanum, neodymium, erbium, gadolinium, and dysprosium). The preparation of the ligand from condensation reactions (4-antipyrinecarboxaldehyde with ethylene di-amine) at room temperature, and was characterization using spectroscopic and analytical studies ( FT-IR, UV-visible spectra, 1H-NMR, mass spectrometry, (C.H.N.O), thermogravimetric analysis (TGA), in addition to the magnetic susceptibility and conductivity measurement of the synthesis complexes, among the results we obtained from the tests, we showed that the ligand behaves with the (triple Valence) lanthanide ions, the multidentate
... Show MoreActivated carbon prepared from date stones by chemical activation with ferric chloride (FAC) was used an adsorbent to remove phenolic compounds such as phenol (Ph) and p-nitro phenol (PNPh) from aqueous solutions. The influence of process variables represented by solution pH value (2-12), adsorbent to adsorbate weight ratio (0.2-1.8), and contact time (30-150 min) on removal percentage and adsorbed amount of Ph and PNPh onto FAC was studied. For PNPh adsorption,( 97.43 %) maximum removal percentage and (48.71 mg/g) adsorbed amount was achieved at (5) solution pH,( 1) adsorbent to adsorbate weight ratio, and (90 min) contact time. While for Ph adsorption, at (4) solution pH, (1.4) absorbent to adsorbate weight ratio, and (120 min) contact
... Show MoreBackground: Suppression of quorum sensing (QS) that regulates many virulence factors, including antimicrobial resistance, in bacteria may subject the pathogenic microbes to the harmful consequences of the antibiotics, increasing their susceptibility to such drugs. Aim: The current study aimed to make an aqueous crude extract from the soil Proteus mirabilis isolate with the use of the gas chromatography-mass spectrometry (GC-MS) technique for its analysis, and then, study the impact of the extract on clinical isolates of Pseudomonas aeruginosa. Methods: Preparation of crude extracts from P. mirabilis (both organic and aqueous), which were then analyzed by GC-MS to detect the bioactive ingredients. Furthermore, the extract’s capability to i
... Show MoreCombining different treatment strategies successively or simultaneously has become recommended to achieve high purification standards for the treated discharged water. The current work focused on combining electrocoagulation, ion-exchange, and ultrasonication treatment approaches for the simultaneous removal of copper, nickel, and zinc ions from water. The removal of the three studied ions was significantly enhanced by increasing the power density (4–10 mA/cm2) and NaCl salt concentration (0.5–1.5 g/L) at a natural solution pH. The simultaneous removal of these metal ions at 4 mA/cm2 and 1 g NaCl/L was highly improved by introducing 1 g/L of mordenite zeolite as an ion-exchanger. A remarkable removal of heavy metals was reported
... Show MoreThe research studied and analyzed the hybrid parallel-series systems of asymmetrical components by applying different experiments of simulations used to estimate the reliability function of those systems through the use of the maximum likelihood method as well as the Bayes standard method via both symmetrical and asymmetrical loss functions following Rayleigh distribution and Informative Prior distribution. The simulation experiments included different sizes of samples and default parameters which were then compared with one another depending on Square Error averages. Following that was the application of Bayes standard method by the Entropy Loss function that proved successful throughout the experimental side in finding the reliability fun
... Show MoreCadmium oxide CdO thin films were prepared by successive ionic layer adsorption and reaction (SILAR) technique at varying number of dippings. The CdO thin films were prepared from a source material of Cadmium acetate and ammonium hydroxide solution deposited on glass substrate at 95℃. The prepared thin films were investigated by X-ray diffraction (XRD), Atomic force microscopy (AFM), Scanning Electron Microscopy (SEM), Fourier Transform Infrared (FTIR), and UV-Visible spectrometry. The XRD analysis reveals that the films were polycrystalline with cubic structure having preferential orientation along (1 1 1), (2 0 0), (2 2 0), and (3 1 1) planes. While the tests of the scanning electron microscopy and the atomic force mic
... Show MoreThe aim of study was to assess water stress for 2,8,14 days and spraying selenium at 0,10,20 mg/L-1 and brassinolide 0,1,2 mg/L-1 on vegetative growth and macro elements content (NPK) for Coriander (Coriandrum astivum L.) plant, The experiment was performed with Factorial Randomized Block Design (R.B.C.D) with three replicates .The results were summarized as follows: 1- The period of sever water stress for 14 days was passive effect on growth parameters. 2- The means of elements content NPK content was increased at moderate stress for 8 days. 3- The effect of selenium and brassinolide was positively to increase studied parameters. 4- Selenium and Brassinolide decreased water stress also the triple in
... Show MoreA new Turbidimetric method characterized by simplicity, accuracy and speed for determination of Hydronium ion by continuous flow injection analysis. The method was based on the formation of complex Zn3[Fe(CN)6] for Zinc(II) that was eluted by Hydronium ion from cation exchanger column with Potassium hexacyanoferrate(III) for the formation of a pale yellow precipitate and this precipitate was determined using homemade Linear Array Ayah-5SX1-T-1D continuous flow injection analyser. The optimum parameters were 2.7 mL.min-1 flow rate using H2O as a carrier stream, 1.7 mL.min-1 reagent stream, 110 L sample volume and open valve for the purge of the sample segment. Data treatment shows that linear range 0.01-0.1 mol.L-1 for each acids (HClO
... Show More