Preferred Language
Articles
/
ZealL5wBmraWrQ4daEe0
Towards Monitoring of the Progress of Chemical Reactions Using a Novel Plasma-Assisted Desorption Ionisation Mass Spectrometry Methodology
...Show More Authors

A novel method for monitoring of pharmaceutically relevant reactions using PADI-MS has been developed in this study. The visible non-thermal plasma plume from a coaxial helium gas flow non-thermal RF plasma was optimised using a range of samples. PADI-MS was found to be a powerful analytical technique for pharmaceutically relevant solid and liquid samples and can readily be adapted for use in reaction monitoring. This study has determined that PADI-MS is fast, easy to set up and requires little or no sample preparation. PADI-MS has significant advantages over other techniques as it is faster, more sensitive and more convenient and suitable for investigation of complex molecules and mixtures. However, two limitations of PADI-MS are that the plasma can affect the sample surface chemistry upon exposure and quantification is not always trivial.

Publication Date
Wed Jan 01 2020
Journal Name
Annals Of Tropical Medicine And Public Health
EFFECT OF EUCALYPTUS AND MYRTUS EXTRACTS IDENTIFICATION BY GAS CHROMATOGRAPHY-MASS SPECTROMETRY ON SOME SPECIES OF CANDIDA AS A MODEL OF MEDICAL PLANTS
...Show More Authors

View Publication
Scopus (6)
Crossref (3)
Scopus Crossref
Publication Date
Sat Mar 01 2014
Journal Name
Food Chemistry
Micro-solid phase extraction with liquid chromatography–tandem mass spectrometry for the determination of aflatoxins in coffee and malt beverage
...Show More Authors

A single step extraction-cleanup procedure using porous membrane-protected micro-solid phase extraction (μ-SPE) in conjunction with liquid chromatography–tandem mass spectrometry for the extraction and determination of aflatoxins (AFs) B1, B2, G1 and G2 from food was successfully developed. After the extraction, AFs were desorbed from the μ-SPE device by ultrasonication using acetonitrile. The optimum extraction conditions were: sorbent material, C8; sorbent mass, 20 mg; extraction time, 90 min; stirring speed, 1000 rpm; sample volume, 10 mL; desorption solvent, acetonitrile; solvent volume, 350 μL and ultrasonication period, 25 min without salt addition. Under the optimum conditions, enrichment factor of 11, 9, 9 and 10 for AFG2, AFG1

... Show More
View Publication
Scopus (65)
Crossref (64)
Scopus Clarivate Crossref
Publication Date
Sat Jun 19 2021
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Serum Chitotriosidase level as a Novel Biomarker for Therapeutic Monitoring of Nephropathic Cystinosis among the Iraqi children
...Show More Authors

Background: Cystinosis is a rare autosomal recessive lysosomal storage disease with high morbidity and mortality. It is caused by mutations in the CTNS gene that encodes the cystine transporter, cystinosin, which leads to lysosomal cystine accumulation. It is the major cause of inherited Fanconi syndrome, and should be suspected in young children with failure to thrive and signs of renal proximal tubular damage. The diagnosis can be missed in infants, because not all signs of renal Fanconi syndrome are present during the first months of life. Elevated white blood cell cystine content is the cornerstone of the diagnosis. Since chitotriosidase (CHIT1 or chitinase-1) is mainly produced by activated macrophages both in normal and inflammator

... Show More
View Publication Preview PDF
Scopus (2)
Scopus Crossref
Publication Date
Fri Oct 01 2010
Journal Name
Analytica Chimica Acta
A reversed phase high performance liquid chromatography method for the determination of fumonisins B1 and B2 in food and feed using monolithic column and positive confirmation by liquid chromatography/tandem mass spectrometry
...Show More Authors

The development of a reversed phase high performance liquid chromatography fluorescence method for the determination of the mycotoxins fumonisin B1 and fumonisin B2 by using silica-based monolithic column is described. The samples were first extracted using acetonitrile:water (50:50, v/v) and purified by using a C18 solid phase extraction-based clean-up column. Then, pre-column derivatization for the analyte using ortho-phthaldialdehyde in the presence of 2-mercaptoethanol was carried out. The developed method involved optimization of mobile phase composition using methanol and phosphate buffer, injection volume, temperature and flow rate. The liquid chromatographic separation was performed using a reversed phase Chromolith® RP-18e column

... Show More
View Publication
Scopus (34)
Crossref (33)
Scopus Clarivate Crossref
Publication Date
Sun Jan 01 2023
Journal Name
Aip Conference Proceedings
Optimization of Fenton process for removal of chemical oxygen demand (COD) from hospital wastewater using response surface methodology (RSM)
...Show More Authors

View Publication
Scopus (4)
Crossref (3)
Scopus Crossref
Publication Date
Tue Jul 29 2025
Journal Name
Plasmonics
Innovative Jet Plasma-Assisted Green Synthesis of TiO2@Ag Core–Shell Nanoparticles Using Chard Leaf Extract for Antibacterial Applications
...Show More Authors

This study presents, for the first time, an innovative Jet Plasma-assisted technique for the green synthesis of TiO₂@Ag core–shell nanoparticles using chard leaf extract as a natural reducing and stabilizing agent. The Jet Plasma provides a highly energetic environment that accelerates nucleation and core–shell formation at low temperatures without toxic precursors. The synthesized nanoparticles exhibited uniform and stable structures, as confirmed by comprehensive characterization techniques including X-ray diffraction (XRD), Fourier-transform infrared spectroscopy (FTIR), ultraviolet–visible (UV–Vis) spectroscopy, transmission electron microscopy (TEM), and zeta potential analysis. XRD patterns confirmed the crystalline anatase

... Show More
View Publication Preview PDF
Scopus (3)
Crossref (1)
Scopus Crossref
Publication Date
Sun Apr 30 2023
Journal Name
Iraqi Geological Journal
Pore Structure Characterization of Shale Reservoir Using Nitrogen Adsorption-Desorption
...Show More Authors

This research paper aimed to quantitively characterize the pore structure of shale reservoirs. Six samples of Silurian shale from the Ahnet basin were selected for nitrogen adsorption-desorption analysis. Experimental findings showed that all the samples are mainly composed of mesopores with slit-like shaped pores, as well as the Barrett-Joyner-Halenda pore volume ranging from 0.014 to 0.046 cm3/ 100 g, where the lowest value has recorded in the AHTT-1 sample, whereas the highest one in AHTT-6, while the rest samples (AHTT-2, AHTT-3, AHTT-4, AHTT-5) have a similar average value of 0.03 cm3/ 100 g. Meanwhile, the surface area and pore size distribution were in the range of 3.8 to 11.1 m2 / g and 1.7 to 40 nm, respectively.

... Show More
View Publication
Scopus (3)
Crossref (2)
Scopus Crossref
Publication Date
Sun Jan 01 2023
Journal Name
Desalination And Water Treatment
Optimization of chemical oxygen demand removal from petroleum refinery wastewater by electrocoagulation using tubular electrochemical reactor with a novel design
...Show More Authors

View Publication
Scopus (4)
Crossref (4)
Scopus Clarivate Crossref
Publication Date
Sun Jun 07 2009
Journal Name
Baghdad Science Journal
The adsorption-desorption process as a method for separation of nitrogen-carbon dioxide gas mixture using activated carbon
...Show More Authors

Gas adsorption phenomenon on solid surface has been used as a mean in separation and purification of gas mixture depending on the difference in tendencies of each component in the gas mixture to be adsorbed on the solid surface according to its behaviour. This work concerns to study the possibilities to separate the gas mixture using adsorption-desorption phenomenon on activated carbon. The experimental results exhibit good separation factor at temperature of -40 .

View Publication Preview PDF
Crossref
Publication Date
Tue Jan 08 2019
Journal Name
Iraqi Journal Of Physics
Effect of plasma jet on the water and hydrogen peroxide that used for assisted teeth bleaching
...Show More Authors

In this work the interaction of plasma jet with water and hydrogen peroxide liquids used for assisted teeth bleaching by plasma jet had been study. A homemade plasma jet system was used. The plasma jet supply by 15 W electrical power generated by high voltage power supply of 9.6 kV peak to peak and frequency of 33 kHz .this power supply generate high electric field on electrodes that would be enough to ionize the argon gas. Some important agents were study such as the effect of the Ar gas flow rates on the length of the plasma jet, the influence of plasma jet on some properties of water and two hydrogen peroxide concentrations 25 % and 30 % like pH, conductivity and liquid temperature for different exposure time. The liquids temperature

... Show More
View Publication Preview PDF
Crossref (2)
Crossref