—This paper studies the control motion of a single link flexible joint robot by using a hierarchical non-singular terminal sliding mode controller (HNTSMC). In comparison to the conventional sliding mode controller (CSMC), the proposed algorithm (NTSMC) not only can conserve characteristics of the convention CSMC, such as easy implementation, guaranteed stability and good robustness against system uncertainties and external disturbances, but also can ensure a faster convergence rate of the systems states to zero in a finite time and singularity free. The flexible joint robot (FJR) is a two degree of freedom (2DOF) nonlinear and underactuated system. The system here is modeled as a fourth order system by using Lagrangian method. Based on the modeling dynamics, the system is decomposed hierarchically into two-second order subsystems, namely, a rigid body and a flexible subsystem. In the first level, the sliding manifold for each subsystem is designed based on the NTS surfaces. Then, in the second level, the total sliding surface is constructed as the linear combination of NTS surfaces of two subsystems. Thereafter, a HNTSM control is obtained based on Lyapunov theorem to drive both subsystems to their equilibrium points in the finite time. Simulation results demonstrate the effectiveness of proposed scheme (HNTSMC) over (HCSMC).
The study of the validity and probability of failure in solids and structures is highly considered as one of the most incredibly-highlighted study fields in many science and engineering applications, the design analysts must therefore seek to investigate the points where the failing strains may be occurred, the probabilities of which these strains can cause the existing cracks to propagate through the fractured medium considered, and thereafter the solutions by which the analysts can adopt the approachable techniques to reduce/arrest these propagating cracks.In the present study a theoretical investigation upon simply-supported thin plates having surface cracks within their structure is to be accomplished, and the applied impact load to the
... Show MoreIn this work laser detection and tracking system (LDTS) is designed and implemented using a fuzzy logic controller (FLC). A 5 mW He-Ne laser system and an array of nine PN photodiodes are used in the detection system. The FLC is simulated using MATLAB package and the result is stored in a lock up table to use it in the real time operation of the system. The results give a good system response in the target detection and tracking in the real time operation.
The study aimed to clarify the meanings learned and inferred from reading books، letters and messages in Surat Al-Qur’an. The inductive method، the analytical method، and the deductive method، One of the most prominent results of the research: that the multiplicity of Qur’anic readings produces a variety and expansion in the meaning that has a clear impact on the interpretation by clarifying the meaning of the verse.
This work presents a completely new develop an analyzer, named NAG-5SX1-1D-SSP, that is simple, accurate, reproducible, and affordable for the determination of cefotaxime sodium (CFS) in both pure and pharmaceutical drugs. The analyzer was designed according to flow injection analysis, and conducted to turbidimetric measurements. Ammonium cerium nitrate was utilized as a precipitating agent. After optimizing the conditions, the analysis system exhibited a linear range of 0.008-27 mmol. L-1 (n=29), with a limit of detection of 439.3 ng/sample, a limit of quantification of 0.4805 mg/sample, and a correlation coefficient of 0.9988. The repeatability of the responses was assessed by performing six successive injections of CFS at concentra
... Show MoreA vascular necrosis (AVN) is defined as cellular death of bone components due to interruption of the blood supply; the bone structures then collapse, resulting in bone destruction, pain, and loss of joint function. AVN is associated with numerous conditions and usually involves the epiphysis of long bones, such as the femoral head. In clinical practice, AVN is most commonly encountered in the hip. Early diagnosis and appropriate intervention can delay the need for joint replacement. However, most patients present late in the disease course. Without treatment, the process is almost always progressive, leading to joint destruction within 5 years. Treatment of a vascular necrosis depends mainly on early diagnosis which mainly based on clinical
... Show MoreBackground/Aim: Knee osteoarthritis is a frequently crippling chronic condition. Numerous pharmacological medications have been successfully utilised to treat knee osteoarthritis. This research aimed to compare the efficiency of metformin and serratiopeptidase in treating and preventing osteoarthritis development via distinct mechanisms. Methods: Between 1 January and 30 May 2019, a randomised-clinical-trial was done at Al-Kindy Hospital on 80 osteoarthritis patients, divided in two groups. Group I was given metformin 850 mg orally, whereas Group II was given serratiopeptidase 20 mg and metformin 850 mg orally. Parameters in these groups were compared with forty healthy normal controls. Results: Following treatment, patients in Grou
... Show MoreBackground: Osteoarthritis OA is the most common joint disorder in the world. Injection of high molecular weight hyaluronic acid intra-articular with steroid is a one of the used therapeutic option for patients with (OA)knee.
Objectives: Objective of this study was the evaluation the efficacy, safety, pluse duration of action of viscosupplementation of the HMWHA( high molecular weight hyluranic acid ).
Type of the study: Cross-sectional study.
Methods: From 81 patients with sever knee pain due to OA (grades 3–4) were recruited from Al-Yarmouk teaching hospital & a private clinic during the period from January 2014 till July 2016.
... Show MoreBackground: Optimal root canal retreatment was required safe and efficient removal of filling material from root canal. The aim of this in vitro study was to compare the efficacy of reciprocating and continuous motion of four retreatment systems in removal of root canal filling material. Materials and Methods: Forty distal roots of the mandibular first molars teeth were used in this study, these roots were embedded in cold clear acrylic,roots were instrumented using crown down technique and rotary ProTaper systemize Sx to size F2 ,instrumentation were done with copiousirrigation of 2.5% sodium hypochlorite and 17% buffered solution of EDTA was used as final irrigant followed by distilledwater, roots were obturated with AH26 sealer and Prota
... Show MoreIntroduction Periodontal diseases are ranked among the most common health problems affecting mankind. These conditions are initiated by bacterial biofilm, which is further modulated by several risk factors. Objectives To investigate the association of different risk factors with periodontal...