Background: Mesh infection after hernia repair is a devastating complication. Preoperative prediction of high risk patients may be useful to avoid infections. This study aims at evaluating risk factors for mesh related wound infection in our setting.
Patients and methods: This prospective cohort analysis study included 120 patients underwent ventral hernioplasty with polypropylene mesh from October 2009 to February 2013 at Baghdad Teaching Hospital. Clinical data analyzed to determine risk factors of mesh related wound infection.
Results: After one year follow up for each of 120; 21 patients (17.5%) developed mesh related wound infection. Predictors of infection were: age ≥ 45 years, BMI≥35 kg/m2, diabetes mellitus, past histor
Background:Incisional hernia is frequently occurring post operative complication after general surgery with occurance rate 2%-----11%,, it is either appear soon after operation or
late occurring incisional hernia..
Patient &methods: This is a prospective study that was conducted on 84 patients who were admitted at Baghdad Teaching Hospital during the period from Oct. 1999 to Aug. 2001 for
repair of incisional hernias. Their ages were ranging from 24-74 years with mean age of (48 ±12). Sixty-nine patients were elective and 15 patients were urgent. Assessment of the patients
for the predisposing factors influencing the development of incisional hernia was done and in our study these factors were: -
R
In this work ,the modified williamos-Hall method was used to analysis the x-ray diffraction lines for powder of magnesium oxide nanoparticles (Mgo) .and for diffraction lines (111),(200),(220),(311) and (222).where by used special programs such as origin pro Lab and Get Data Graph ,to calculate the Full width at half maximum (FWHM) and integral breadth (B) to calculate the area under the curve for each of the lines of diffraction .After that , by using modified Williamson –Hall equations to determin the values of crystallite size (D),lattice strain (ε),stress( σ ) and energy (U) , where was the results are , D=17.639 nm ,ε =0.002205 , σ=0.517 and U=0.000678 respectively. And then using the scherrer method can by calculated the crystal
... Show MoreBackground: Radiopacity is one of the prerequisites for dental materials, especially for composite restorations. It's essential for easy detection of secondary dental caries as well as observation of the radiographic interface between the materials and tooth structure. The aim of this study to assess the difference in radiopacity of different resin composites using a digital x-ray system. Materials and methods: Ten specimens (6mm diameter and 1mm thickness) of three types of composite resins (Evetric, Estelite Sigma Quick,and G-aenial) were fabricated using Teflon mold. The radiopacity was assessed using dental radiography equipment in combination with a phosphor plate digital system and a grey scale value aluminum step wedge with thickness
... Show MoreThe paired sample t-test is a type of classical test statistics that is used to test the difference between two means in paired data, but it is not robust against the violation of the normality assumption. In this paper, some alternative robust tests are suggested by combining the Jackknife resampling with each of the Wilcoxon signed-rank test for small sample size and Wilcoxon signed-rank test for large sample size, using normal approximation. The Monte Carlo simulation experiments were employed to study the performance of the test statistics of each of these tests depending on the type one error rates and the power rates of the test statistics. All these tests were applied on different sa
... Show MoreBackground: Radiopacity is one of the prerequisites for dental materials, especially for composite restorations. It's essential for easy detection of secondary dental caries as well as observation of the radiographic interface between the materials and tooth structure. The aim of this study to assess the difference in radiopacity of different resin composites using a digital x-ray system. Materials and methods: Ten specimens (6mm diameter and 1mm thickness) of three types of composite resins (Evetric, Estelite Sigma Quick,and G-aenial) were fabricated using Teflon mold. The radiopacity was assessed using dental radiography equipment in combination with a phosphor plate digital system and a grey scale value aluminum step wedge with thickness
... Show MoreIn this paper, suggested formula as well a conventional method for estimating the twoparameters (shape and scale) of the Generalized Rayleigh Distribution was proposed. For different sample sizes (small, medium, and large) and assumed several contrasts for the two parameters a percentile estimator was been used. Mean Square Error was implemented as an indicator of performance and comparisons of the performance have been carried out through data analysis and computer simulation between the suggested formulas versus the studied formula according to the applied indicator. It was observed from the results that the suggested method which was performed for the first time (as far as we know), had highly advantage than t
... Show MoreIn this research a computational simulation has been carried out on the design and properties of the electrostatic mirror and a mathematical expression has been suggested to represent the axial potential of an electrostatic mirror. The electron beam path using the Bimurzaev technique had been investigated as mirror trajectory with the aid of Runge – Kutta method. The spherical and chromatic aberration coefficients of mirror has computed and normalized in terms of the focal length. The choice of the mirror depends on the operational requirements. The Electrode shape of mirror two electrodes has been determined by using package SIMION computer program. Computations have shown that the suggested potentials giv
... Show MoreThis paper presents a modified training method for Recurrent Neural Networks. This method depends on the Non linear Auto Regressive (NARX) model with Modified Wavelet Function as activation function (MSLOG) in the hidden layer. The modified model is known as Modified Recurrent Neural (MRN). It is used for identification Forward dynamics of four Degrees of Freedom (4-DOF) Selective Compliance Assembly Robot Arm (SCARA) manipulator robot. This model is also used in the design of Direct Inverse Control (DIC). This method is compared with Recurrent Neural Networks that used Sigmoid activation function (RS) in the hidden layer and Recurrent Neural Networks with Wavelet activation function (RW). Simulation results shows that the MRN model is bett
... Show More