Abstract Background: The novel coronavirus 2 (SARS?CoV?2) pandemic is a pulmonary disease, which leads to cardiac, hematologic, and renal complications. Anticoagulants are used for COVID-19 infected patients because the infection increases the risk of thrombosis. The world health organization (WHO), recommend prophylaxis dose of anticoagulants: (Enoxaparin or unfractionated Heparin for hospitalized patients with COVID-19 disease. This has created an urgent need to identify effective medications for COVID-19 prevention and treatment. The value of COVID-19 treatments is affected by cost-effectiveness analysis (CEA) to inform relative value and how to best maximize social welfare through evidence-based pricing decisions. Objective: compare the clinical outcome and the costs of two anticoagulants (heparin and (enoxaparin)) used to treat hospitalized patients with COVID-19 infection. Patients and method: The study was a retrospective review of medical records of adult, non-pregnant, COVID-19 infected hospitalized patients who had baseline and last outcome measurements at Alamal Epidemiology Center, Al-Najaf city from (Augast 2020 to June 2021). The outcome measures included D-dimer, length of stay (LOS), and mortality rate. Only the cost of the medical treatment was considered in the analysis. The pharmacoeconomics analysis was done in three different cost-effectiveness analysis methods. Microsoft Excel spreadsheet and Statistical Package for the Social Sciences software (SPSS), was used to conduct statistical analysis. Kaplan Meier test was used to compare the mortality rate. T-TEST was used to compare the outcomes of the two groups. Results and discussion: two groups were compared, the first group consists of 72 patients who received heparin, and the second group consists of 72 patients who received enoxaparin. COVID-19 infected patients had a higher abnormal average D-dimer (2534.675 ng/dl). No significant differences between both genders with regards to the basal average D-dimer (males= 2649.95 ng/dl, females= 2374.1mg/dl, P-value>0.05). There was a significant difference between patient's ages 60 years and patients <60. (3177.33 ng/dl, 1763.06 ng/dl, P-value <0.05). It seems that, higher D-dimer levels were associated with a higher mortality rate (died=3166.263 ng/dl, survived= 1729.94 ng/dl, P-value <0.05). Heparin was more effective in decreasing D-dimer levels than enoxaparin which inversely increased the D-dimer levels (-24.4 ng/dl/day, +154.701 ng/dl/day, P-value <0.05). Additionally, heparin was more effective in increasing the survival rate compared to enoxaparin (55% vs, 35%, P-value<0.05). Heparin was associated with a longer duration of stay in hospital than enoxaparin but with no significant difference (13.7 days, 12.3 days, P-value >0.05). Concerning the cost, treatment with heparin cost less than enoxaparin (2.08 U.S $, 9.44 U.S $)/per patient/per day. Conclusion: Originator heparin was a more cost-effective anticoagulant therapy compared to originator enoxaparin, it was associated with a lower cost and better effect, treatment with Heparin resulted in positive INB= 11.3, where a positive result means that heparin is more cost-effective than Enoxaparin. All three methods of pharmacoeconomic analysis decide that heparin was more cost-effective than enoxaparin in treating COVID-19 infected patients.
Background: Lymphomas are a group of diseases caused by malignant lymphocytes that accumulate in lymph nodes and cause the characteristic clinical features of lymphadenopathy. Intercellular adhesion molecule-1 (ICAM-1) (CD54) is a transmembrane glycoprotein belonging to the immunoglobulin superfamily of adhesion molecules. Cortactin was first identified as one of the major substrates for src kinase. because it localized to Cortical actin structures, The aims of this study was to evaluate and compare the immunohistochemical of ICAM-1 expression as cell adhesion molecule marker and Cortactin expression as invasive marker. Material and Methods: This study was performed on (68) formalin-fixed, paraffin-embedded blocks, histopathologically diagn
... Show MoreStick-slip is kind of vibration which associated with drilling operation in around the bottom hole assembly (BHA) due to the small clearance between drill string & the open hole and due to the eccentric rotating of string. This research presents results of specific experimental study that was run by using two types of drilling mud (Fresh water Bentonite & Polymer), with/without Nanoparticle size materials of MgO in various ratios and computes the rheological properties of mud for each concentration [Yield point, plastic viscosity, Av, PH, filter loss (30 min), filter cake, Mud Cake Friction, Friction Factor]. These results then were used to find a clear effects of Nanoparticle drilling mud rheology on stick - slip strength by sev
... Show MoreBackground: Acute appendicitis is regarded as one of the most common inflammation that needs surgical intervention. Different scoring systems have been used for diagnosing of acute appendicitis. ALVARADO score is one of the most widely used score in diagnosing of acute appendicitis, but the accuracy of the latter is insufficiently low in Middle-East patients. Thus a new scoring system called RIPASA score has been designed for diagnosing of acute appendicitis in those patients. The aim of this study is to use RIPASA score and compare its result with ALVARADO score in diagnosing of acute appendicitis.
Subjects and Methods: The study includes 200 patients with symptoms and signs of
... Show MoreBackground: Complete removal of filling material from the root canal is an essential requirement for endodontic retreatment. The purpose of the present study is to evaluate and compare the dissolving capabilities of various solvents (Xylene, Eugenate Desobturator, Eucalyptol, EDTA and Distilled water (as a control)) on four different types of sealer (Endofill, Apexit Plus, AH Plus and EndoSequence bioceramic sealer). Materials and method: Eighty samples of each sealer were prepared according to the manufacturers' instructions and then divided into ten groups (of 8 samples) for immersion in the respective solvents for 2 and 5 min immersion periods. Each sealer specimen was weighed to obtain its initial mass. The specimens were immersed in
... Show MoreThe need for cloud services has been raised globally to provide a platform for healthcare providers to efficiently manage their citizens’ health records and thus provide treatment remotely. In Iraq, the healthcare records of public hospitals are increasing progressively with poor digital management. While recent works indicate cloud computing as a platform for all sectors globally, a lack of empirical evidence demands a comprehensive investigation to identify the significant factors that influence the utilization of cloud health computing. Here we provide a cost-effective, modular, and computationally efficient model of utilizing cloud computing based on the organization theory and the theory of reasoned action perspectives. A tot
... Show MoreFrictional resistance occurs whenever sliding happens, negatively impacting treatment outcomes and duration. It is a clinical challenge and must be dealt with efficiently to achieve the best orthodontic results. Aims of this study: compare and evaluate the static frictional forces under the wet condition to mimic the oral environment produced by using a polycrystalline ceramic bracket, monocrystalline ceramic bracket, 0.014 of an inch nickel-titanium (Rhodium coated archwires, and ilusio aesthetic archwires), and 0.019 x 0.025 of an inch stainless steel (Rhodium coated archwires, and ilusio aesthetic archwires). Ninety-six aesthetic brackets (48 monocrystalline and 48 polycrystalline brackets) were used and stored in different incub
... Show MoreThis study illustrates the impact of non-thermal plasma (Cold Atmospheric Plasma CAP) on the lipids blood, the study in vivo. The lipids are (cholesterol, HDL-Cholesterol, LDL-Cholesterol and triglyceride) are tested. (FE-DBD) scheme of probe diameter 4cm is used for this purpose, and the output voltage ranged from (0-20) kV with variable frequency (0-30) kHz. The effect of non-thermal atmospheric plasma on lipids were studied with different exposure durations (20,30) sec. As a result, the longer plasma exposure duration decreases more lipids in blood.