Abstract Background: The novel coronavirus 2 (SARS?CoV?2) pandemic is a pulmonary disease, which leads to cardiac, hematologic, and renal complications. Anticoagulants are used for COVID-19 infected patients because the infection increases the risk of thrombosis. The world health organization (WHO), recommend prophylaxis dose of anticoagulants: (Enoxaparin or unfractionated Heparin for hospitalized patients with COVID-19 disease. This has created an urgent need to identify effective medications for COVID-19 prevention and treatment. The value of COVID-19 treatments is affected by cost-effectiveness analysis (CEA) to inform relative value and how to best maximize social welfare through evidence-based pricing decisions. Objective: compare the clinical outcome and the costs of two anticoagulants (heparin and (enoxaparin)) used to treat hospitalized patients with COVID-19 infection. Patients and method: The study was a retrospective review of medical records of adult, non-pregnant, COVID-19 infected hospitalized patients who had baseline and last outcome measurements at Alamal Epidemiology Center, Al-Najaf city from (Augast 2020 to June 2021). The outcome measures included D-dimer, length of stay (LOS), and mortality rate. Only the cost of the medical treatment was considered in the analysis. The pharmacoeconomics analysis was done in three different cost-effectiveness analysis methods. Microsoft Excel spreadsheet and Statistical Package for the Social Sciences software (SPSS), was used to conduct statistical analysis. Kaplan Meier test was used to compare the mortality rate. T-TEST was used to compare the outcomes of the two groups. Results and discussion: two groups were compared, the first group consists of 72 patients who received heparin, and the second group consists of 72 patients who received enoxaparin. COVID-19 infected patients had a higher abnormal average D-dimer (2534.675 ng/dl). No significant differences between both genders with regards to the basal average D-dimer (males= 2649.95 ng/dl, females= 2374.1mg/dl, P-value>0.05). There was a significant difference between patient's ages 60 years and patients <60. (3177.33 ng/dl, 1763.06 ng/dl, P-value <0.05). It seems that, higher D-dimer levels were associated with a higher mortality rate (died=3166.263 ng/dl, survived= 1729.94 ng/dl, P-value <0.05). Heparin was more effective in decreasing D-dimer levels than enoxaparin which inversely increased the D-dimer levels (-24.4 ng/dl/day, +154.701 ng/dl/day, P-value <0.05). Additionally, heparin was more effective in increasing the survival rate compared to enoxaparin (55% vs, 35%, P-value<0.05). Heparin was associated with a longer duration of stay in hospital than enoxaparin but with no significant difference (13.7 days, 12.3 days, P-value >0.05). Concerning the cost, treatment with heparin cost less than enoxaparin (2.08 U.S $, 9.44 U.S $)/per patient/per day. Conclusion: Originator heparin was a more cost-effective anticoagulant therapy compared to originator enoxaparin, it was associated with a lower cost and better effect, treatment with Heparin resulted in positive INB= 11.3, where a positive result means that heparin is more cost-effective than Enoxaparin. All three methods of pharmacoeconomic analysis decide that heparin was more cost-effective than enoxaparin in treating COVID-19 infected patients.
Pure grade II titanium disks were coated with a thin coating of polyetherketoneketone (PEKK) polymer by RF magnetron sputtering using either nitrogen or argon gas. Sputtering technique was employed at 50 W for one hour at 60°C with continuous flow of nitrogen or argon gas. Field-emission scanning electron microscopy (FE-SEM) showed a continuous, homogeneous, rough PEKK surface coating without cracks. In addition, cross-sectional FE-SEM revealed an average coat thickness of 1.86 μm with argon gas and 1.96 μm with nitrogen gas. There was homogenous adhesion between the coating layer and substrate. The elemental analysis of titanium substrate revealed the presence of carbon, titanium, and oxygen. The RF magnetron sputtering with argon or ni
... Show MoreA true random TTL pulse generator was implemented and investigated for quantum key distribution systems. The random TTL signals are generated by low cost components available in the local markets. The TTL signals are obtained by using true random binary sequences based on registering photon arrival time difference registered in coincidence windows between two single – photon detectors. The true random TTL pulse generator performance was tested by using time to digital converters which gives accurate readings for photon arrival time. The proposed true random pulse TTL generator can be used in any quantum -key distribution system for random operation of the transmitters for these systems
Abstract
This research aims to study the reflection of accounting for contingent assets and liabilities and provisions on Faithful Representation characteristic of accounting information, To achieve this goal has been questionnaire design has been distributed to research sample, which consists of (50) li
... Show MoreThis study was conducted in the botanical garden, Department of biology, College of Science/ Mustansiriyah University in from (15 February to 15 March, 2019) under the natural environmental conditions in the greenhouse in order to evaluate the effectiveness of parsley aqueous extract as a promoter for rooting. The study included the use of aqueous extract of a plant Parsley (Petroselinum crispum) extract was used in concentrations (1.25, 2.5 g / l), compare with IBA in concentration (100 mg / L) with dipping time 24 hour for all treatments. The cutting stems were included Rosmarinus officinalis, Nerium oleander, Olea europaea, Plumeria alba, Hibiscus rosa, Pelargonium graveolens, and Myrtus communis. The following measurements were
... Show MorePhotonic crystal fiber interferometers (PCFIs) are widely used for sensing applications. This work presented solid core-PCFs based on Mach-Zehnder modal interferometer for sensing refractive index. The general structure of sensor was applied by splicing short lengths of PCF in both sides with conventional single mode fiber (SMF-28).To apply modal interferometer theory collapsing technique based on fusion splicing used to excite higher order modes (LP01 and LP11). A high sensitive optical spectrum analyzer (OSA) was used to monitor and record the transmitted wavelength. This work studied a Mach-Zahnder interferometer refractive index sensor based on splicing point tapered SMF-PCF-SMF. Relation between refractive index sensitivity and tape
... Show MoreIn this paper, we investigate two stress-strength models (Bounded and Series) in systems reliability based on Generalized Inverse Rayleigh distribution. To obtain some estimates of shrinkage estimators, Bayesian methods under informative and non-informative assumptions are used. For comparison of the presented methods, Monte Carlo simulations based on the Mean squared Error criteria are applied.
The important of present study is to design rehabilitation program by using hypermedia for some injuries of smooth tissues in shoulder joint. This joint is most important to help badminton players in achieving their daily and sport tasks due to upper limp movements depend on health and active of this joint. Experimental approach with a manner of equal single station was used in present study and study simple consisted of 6 badminton players from Babylon and Al-Mahaweel clubs who have less sharp tissue smooth injury such (muscles, ligaments, pocket). We used (SPSS) to analyses pre, medal, post-tests data. In conclusion, hypermedia is positive benefit to rehabilitee of injuries of smooth tissues in shoulder joint for badminton pla
... Show More