Experimental and Numerical Analysis of the Punching Shear Resistance Strengthening of Concrete Flat Plates by Steel Collars
...Show More Authors

In this study, six square reinforced concrete flat plates with dimensions of (1500×1500×100) mm were tested under a concentrated load applied on a column located at the center of the slabs. One of these slabs was the control specimen, whereas, in the others, steel angles (steel collars) were used, fixed at the connection region between the slab and the column to investigate the effect of the presence of these collars on punching shear strength. Five thicknesses were used (4, 5, 6, 8, 10mm) with constant legs of angles (75×75) mm of the steel collars to investigate the effects on the punching shear resistance with respect to the control slab. The results of the experimental study show that the punching shear resistance increased by 41 to 77% when steel collars were used. The experimental results were in good agreement with the numerical analysis acquired with the ABAQUS software.

Scopus Crossref
Publication Date
Wed Jun 28 2023
Journal Name
Engineering Applications Of Computational Fluid Mechanics
Comprehensive analysis of melting enhancement by circular Y-shaped fins in a vertical shell-and-tube heat storage system
...Show More Authors

View Publication
Scopus (7)
Crossref (3)
Scopus Clarivate Crossref
Publication Date
Tue Nov 26 2019
Journal Name
Journal Of Engineering
The Experimental Assessment of R134a and Its Lower GWP Alternative R1234yf in an Automobile Air Conditioning System
...Show More Authors

Reducing global warming potential (GWP) of refrigerants is needed to the decrease of ozone-depleting of refrigeration systems leakages. Refrigerant R1234yf is now used to substitute R134a inside mobile air conditioning systems. Thermodynamic properties of R1234yf are similar to R134a. Also, it has a very low GWP of 4, compared to 1430 for R134a, making it a proper choice for future automobile refrigerants. The purpose of this research is to represent the main operating and performance differences between R1234yf and R134a. Experimental analysis was carried out on the automotive air conditioning system (AACS) with 3 kW nominal capacity, to test and compare the performance of R134a with R1234yf. Experiments were accomplish

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Wed Nov 27 2019
Journal Name
Iraqi Journal Of Science
Comparative Study of Some Virulence Factors and Analysis of Phylogenetic Tree by 16S rDNA Sequencing of Aeromonas hydrophila Isolated from Clinical and Environmental Samples
...Show More Authors

     Aeromonas hydrophila is widely distributed throughout the world and causes diseases to animals and human exposed to contaminated environments such as water and soil. This study aimed to compare between isolates of A. hydrophila collected from clinical and environmental samples, through investigating the phenotype of some virulence factors in vitro, including hemolysin, protease, lipase, nuclease and biofilm formation ability. Also, the antimicrobial susceptibility for different antibiotics was determined using disc diffusion method. For genotypic identification of isolates and phylogenetic tree construction, 16S rDNA target gene was amplified and sequenced. The phenoty

... Show More
View Publication Preview PDF
Scopus (2)
Scopus Crossref
Publication Date
Sun Jan 01 2023
Journal Name
Journal Of Clinical And Experimental Dentistry
Preventive effect of combined Er, Cr: YSGG and fluoride gel on acid resistance of the permanent tooth enamel: An in vitro study
...Show More Authors

View Publication
Crossref (1)
Crossref
Publication Date
Sun Sep 29 2019
Journal Name
Iraqi Journal Of Science
The Competition between of invasive Hydrilla verticillata L.f. and native Ceratophyllum demersum L. in monocultures and mixed cultures experimental
...Show More Authors

     The present study aims to assess inter-specific competition between Hydrilla verticillata and Ceratophyllum demersum. A competition experiment design has five treatment combinations to terminal shoots of C. demersum only, terminal shoots of H. verticillata only and three different treatment combinations of C. demersum and H. verticillata together. Our results showed parameters growth of C. demersum were decreased of which, total chlorophyll, protein, and biomass while Superoxide dismutase (SOD), and Catalase (CAT) enzymes increase were significantly (p<0.05) compare with control treatment. While H. verticillata were increased total chlorop

... Show More
View Publication Preview PDF
Scopus (1)
Scopus Crossref
Publication Date
Thu Dec 01 2011
Journal Name
Journal Of Engineering
THEORETICAL AND EXPERIMENTAL STUDY ON THERMAL PERFORMANCE OF CLOSED WET COOLING TOWER
...Show More Authors

Thermal performance of closed wet cooling tower has been investigated experimentally and theoretically
in this work. The theoretical model based on heat and mass transfer equations and heat and mass transfer balance equations which are established for steady state case. A new small indirect cooling tower was used for conducting experiments. The cooling capacity of cooling tower is 1 kW for an inlet water temperature of 38oC, a water mass velocity 2.3 kg/m2.s and an air wet bulb temperature of 26oC. This study investigates the relationship between saturation efficiency, cooling capacity and coefficient of performance of closed wet cooling tower versus different operating parameters such wet-bulb temperature, variable air-spray water fl

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Mar 30 2003
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Physical and Rheological Properties of Class "G" Gilsonite Cement Slurries (Experimental Study)
...Show More Authors

View Publication Preview PDF
Publication Date
Wed Aug 07 2024
Journal Name
Civileng
Experimental and FE Investigations of Backfill Cover on Large-Diameter GRP Pipes
...Show More Authors

This paper presents experimental investigations on buried Glass Reinforced Plastic (GRP) pipes with a diameter of 1400 mm. The tested pipes were buried in dense, gravelly sand and subjected to traffic loads to study the effects of backfill cover on pipe deflection. The experimental program included tests on three GRP pipes with backfill covers of 100 cm, 75 cm, and 50 cm. The maximum traffic loads applied to the pipe–soil system corresponded to Iraqi Truck Type 3 (AASHTO H type). Vertical deflections of the pipes were monitored during the application of these loads. The experimental results showed that, as the backfill cover increased, the maximum vertical deflection of the pipe decreased. Deflection reductions were 38.0% and 33.3

... Show More
View Publication
Scopus Clarivate Crossref
Publication Date
Mon Jun 01 2020
Journal Name
Journal Of Engineering
Thermal Modeling of Solar Still Coupled with Heat Pipes and Experimental Validation
...Show More Authors

Water is the basis of the existence of all kinds of life, so obtaining it with good quality represents a challenge to human existence and development especially in the desert and remote cities because these areas contain small populations and water purification requires great materials and huge amounts of fossil fuels resulting pollution of the environment. Cheap and environmentally friendly desalination methods have been done by using solar distillations. Passive solar stills have low yields, so in this research, the problem is overcome by connecting four heat pipes which are installed on the parabolic concentrator reflector with passive solar still to increase the temperature of hot water to more than 90°C, as a resul

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Sep 08 2006
Journal Name
Journal Of Engineering
INFLUENCE OF DEFECT IN THE CONCRETE PILES USING NON-DESTRUCTIVE TESTING
...Show More Authors

This paper presents the results of experimental investigation carried out on concrete model piles to study the behaviour of defective piles. This was achieved by employing non-destructive tests using ultrasonic waves. It was found that the reduction in pile stiffness factor is found to be about (26%) when the defect ratio increased from (5%) to (15%). The modulus of elasticity reduction factor as well as the dynamic modulus of elasticity reduction factor increase with the defect ratio