A new method, simple and sensitive was utilized in determining mebeverine – HCl (MB-HCl) (3, 4-Dimethoxy benzoic acid ethyl 2, 4 methoxy4-phenyl-1-methyl ethyl amino-butyl ester) in pure and pharmaceutical formulations via utilization this multiple continuous flow cell. The method is dependent on genesis for complex of ion pair(4-((3, 4-dimethoxybenzoyl) oxy)-N-ethyl-N-(1-(4-methoxyphenyl) propan-2-yl) butan-1-aminium-2-hydroxy-3,5- dinitrobenzoate) among mebeverine–HCl (MB-HCl) and 3,5-Dinitrosalicylic acid (3,5-DNSA) in ammonium acetate middle to configure a whiteish yellow precipitate compound via utilizing multiple continuous flow cell that works as a solo flow cell with 4S×3 – 3D analyzer. Optimum parameters were studied to raise the sensitivity for improving the method. The linear dynamic range of calibration graph 0.5 – 60 mmol / L and LOD 582.5 ng /125 µL with correlation coefficient (r) 0.9783, RSD% was less than 0.5 %, (n = 6) for estimate of (MB-HCl) in concentration (13, 30) mmol / L. The results were compared together, traditional way method UV-Sp, via using the method of measuring additions by t-test and F-test, in 95% confidence plane. Comparing results explained that multiple continuous flow cell that works as a solo flow cell with 4S×3 – 3D analyzer is the good choice and widely utilized in applications.
High cost of qualifying library standard cells on silicon wafer limits the number of test circuits on the test chip. This paper proposes a technique to share common load circuits among test circuits to reduce the silicon area. By enabling the load sharing, number of transistors for the common load can be reduced significantly. Results show up to 80% reduction in silicon area due to load area reduction.
Numerical study is adapted to combine between piezoelectric fan as a turbulent air flow generator and perforated finned heat sinks. A single piezoelectric fan with different tip amplitudes placed eccentrically at the duct entrance. The problem of solid and perforated finned heat sinks is solved and analyzed numerically by using Ansys 17.2 fluent, and solving three dimensional energy and Navier–Stokes equations that set with RNG based k−ε scalable wall function turbulent model. Finite volume algorithm is used to solve both phases of solid and fluid. Calculations are done for three values of piezoelectric fan amplitudes 25 mm, 30 mm, and 40 mm, respectively. Results of this numerical study are compared with previous b
... Show MoreThis study aimed to identify the changes in total protein in saliva and sera samples of patients with oral squamous cell carcinoma in comparison to those of healthy controls. These changes were followed using electrophoresis (PAGE). Meanwhile, determinations of albumin, globulin and albumin to globulin ratio were carried out on sera samples only.Two groups were the participants in the present study, 18 patients with Oral Squamous Cell Carcinoma (OSCC), and 20 ages and gender matched healthy controls.
An overall mathematical model for copper pipe corrosion in flowing water was derived based on mass transfer fundamentals where we introduced the effects of boundary layer velocity, bulk flow velocity and the surface oxide protective film on the corrosion rate. A set of experiments were conducted in a straight 10mm diameter copper pipe, flow of water include six velocities of maximum value 7.33m/sec at 200C and 350C. The good agreement between the calculated and experimental corrosion rate values were achieved , the agreement reached 92% .
Background: Verrucous carcinoma (VSCC) is considered as a rare well differentiated carcinoma variant of SCC with no metastatic potential. The aim of this study is to evaluate the Immunohistochemical expression MMP-2, VEGF and D2-40 expression in OSCC and VSCC. Materials and methods: Thirty formalin fixed paraffin embedded tissue blocks of OSCC and another twelve VSCC were collected and Four micrometer thick sections were cut from each block and mounted on positively charged slides and stained immunohistochemically with monoclonal antibodies to MMP-2, VEGF and D2-40. Results: there is no statistical difference between SCC and VSCC regarding the immunoexpression of MMP-2 and VEGF. While the lymphatic vessels density were higher in SCC than V
... Show MoreQuantum dots of CdSe, CdS and ZnS QDs were prepared by chemical reaction and used to fabricate organic quantum dot hybrid junction device. QD-LEDs were fabricated using layers of ITO/TPD: PMMA/CdSe/Alq3, ITO/TPD: PMMA/CdS/Alq3 and ITO/TPD: PMMA/ZnS/Alq3 devices which prepared by phase segregation method. The hybrid white light emitting devices consists, of three-layers deposited successively on the ITO glass substrate; the first layer was of N, N’-bis (3-methylphenyl)-N, N’-bis (phenyl) benzidine (TPD) polymer mixed with polymethyl methacrylate (PMMA) polymers. The second layer was QDs while the third layer was tris (8-hydroxyquinoline) aluminium (Alq3
... Show MoreThe ligand 4-amino-N-(5-methylisoxazole-3-yl)-benzene-sulfonamide(L1) (as a chelating ligand) was treated with Pd(II),Pt (IV) and Au(III) ions in alcoholic medium in order to prepare a series of new metal complexes. Mixed ligand complexes of this primary ligand were prepared in alcoholic medium in presence of the co-ligand 4,4'-dimethyl-2,2'-bipyridyl(L2) with Cu(II) ,Pd(II) and Au(III) ions. The complexes were characterized in solid state using flame atomic absorption, elemental analysis C.H.N.S, FT-IR, UV-Vis Spectroscopy, conductivity and magnetic susceptibility measurements. The nature of some complexes formed in ethanolic solution has been studied following the molar ratio method, also stability constant was studied and the complexes f
... Show MoreIn this paper, a national grid-connected photovoltaic (PV) system is proposed. It extracts the maximum power point (MPP) using three-incremental-steps perturb and observe (TISP&O) maximum power point tracking (MPPT) method. It improves the classic P&O by using three incremental duty ratio (ΔD) instead of a single one in the conventional P and O MPPT method. Therefore, the system's performance is improved to a higher speed and less power fluctuation around the MPP. The Boost converter controls the MPPT and then is connected to a three-phase voltage source inverter (VSI). This type of inverter needs a high and constant input voltage. A second-order low pass (LC) filter is connected to the output of VSI to reduce t
... Show More