Preferred Language
Articles
/
YobdtoYBIXToZYALYrN1
Performance of reinforced concrete non-prismatic beams having multiple openings configurations
...Show More Authors
Abstract<p>This experimental study demonstrates the gable-reinforced concrete beams’ behavior with several number of openings (six and eight) and posts’ inclination, aimed to find the strength reduction in this type of beam. The major results found are: for the openings extending over similar beam length it is better to increase the number of posts (openings), <italic>i.e.</italic>, increasing opening number led to decrease in opening area, which allows us to transmit stresses and act as lever arms between the upper and the lower chords. Also, findings revealed that the inclined posts have larger loading at the mid-point relative to vertical ones. For gables with vertical posts having six and eight openings, the ultimate strength reduction was 31.5 and 25.6%, whereas it was 29 and 17.3% for those with inclined posts, respectively.</p>
Scopus Clarivate Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Fri Jan 01 2021
Journal Name
Latin American Journal Of Solids And Structures
Structural Behavior of Reinforced Hybrid Concrete Columns under Biaxial Loading
...Show More Authors

Scopus (16)
Crossref (10)
Scopus Clarivate Crossref
Publication Date
Sun Apr 01 2007
Journal Name
Journal Of Engineering
CURVATURE DUCTILITYOF REINFORCED CONCRETE BEAMSECTIONS STIFFENED WITH STEEL PLATES
...Show More Authors

Publication Date
Mon Jun 08 1998
Journal Name
Journal Of King Saud University
Moment Capacity and Strength of Reinforced Concrete Members Using Stress- Strain Diagrams of Concrete and Steel
...Show More Authors

Publication Date
Fri May 01 2015
Journal Name
Journal Of Engineering
Experimental Study of the Thermal Performance of Flat Plate Solar Collectors Array by Different Connection Configurations
...Show More Authors

The current research illustrates experimentally the effect of series and parallel connection (Z-I Configurations) of flat plate water solar collectors array on the thermal performance of closed loop solar heating system. The study includes the effect of changing the water flow rate on the thermal efficiency. The results show that, the collector's efficiency in series connection is higher than the parallel connection within flow rate level less than (100) ℓ/hr. Moreover, the collector efficiency in parallel connection of (I-Configurations) is more than the (Z- Configurations) with increasing the water flow rate .The maximum daily efficiency for parallel (I-Configurations) and (Z- Configurations) are (55%) and (51%) at w

... Show More
View Publication Preview PDF
Publication Date
Thu Feb 01 2024
Journal Name
Journal Of Engineering
Numerical Study of Composite Concrete Castellated Double Channel Beams with Strengthening Techniques
...Show More Authors

Current numerical research was devoted to investigating the effect of castellated steel beams without and with strengthening. The composite concrete asymmetrical double hot rolled steel channels bolted back to back to obtain a built-up I-shape form are used in this study. The top half part of the steel is smaller than the bottom half part, and the two parts were connected by bolting and welding. The ABAQUS/2019 program employed the same length and conditions of loading for four models: The first model is the reference without castellated and strengthening; the second model was castellated without strengthened; the third model was castellated and strengthened with reactive powder concrete encased in the

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Tue Jan 09 2024
Journal Name
Fibers
Flexural Behavior of Pultruded GFRP–Concrete Composite Beams Strengthened with GFRP Stiffeners
...Show More Authors

The utilization and incorporation of glass fiber-reinforced plastics (GFRP) in structural applications and architectural constructions are progressively gaining prominence. Therefore, this paper experimentally and numerically investigates the use of GFRP I-beams in conjunction with concrete slabs to form composite beams. The experimental design incorporated 2600 mm long GFRP I-beams which were connected compositely to concrete slabs with a 500 mm width and 80 mm thickness. The concrete slabs are categorized into two groups: concrete slabs cast using normal-strength concrete (NSC), and concrete slabs prepared using high-strength concrete (HSC). Various parameters like the type of concrete (normal and high-strength concrete), type of

... Show More
View Publication
Scopus (4)
Scopus Clarivate Crossref
Publication Date
Mon Jan 11 2021
Journal Name
Engineering, Technology & Applied Science Research
The Effect of Low Velocity Impact Loading on SelfCompacting Concrete Reinforced with Carbon Fiber Reinforced Polymers
...Show More Authors

t-Self-Compacting Concrete (SCC) reduces environmental noise and has more workability. This research presents an investigation of the behavior of SCC under mechanical loading (impact loading). Two types of cement have been used to produce SCC mixtures, Ordinary Portland Cement (OPC) and Portland Limestone Cement (PLC), which reduces the emission of carbon dioxide during the manufacturing process. The mixes were reinforced with Carbon Fiber Reinforced Polymer (CFRP) which is usually used to improve the seismic performance of masonry walls, to replace lost steel reinforcements, or to increase column strength and ductility. Workability tests were carried out for fresh SCC. Prepared concrete slabs of 500×500×50mm were tested for lo

... Show More
Publication Date
Sun Jul 09 2023
Journal Name
Journal Of Engineering
The Effective Width in Composite Steel Concrete Beams at Ultimate Loads
...Show More Authors

A composite section is made up of a concrete slab attached to a steel beam by means of shear connectors. Under positive and negative bending moment, part of the slab will act as a flange of the beam, resisting the longitudinal compression or tension force. When the spacing between girders becomes large, it is evident that the simple beam theory does not strictly apply because the longitudinal stress in the flange will vary with distance from the girder web, the flange being more highly stressed over the web than in the extremities. This phenomenon is termed "shear lag". In this paper, a nonlinear three-dimensional finite element analysis is employed to evaluate and determine the actual effective slab width of the composite steel-concrete

... Show More
View Publication
Crossref (6)
Crossref
Publication Date
Fri Jun 30 2006
Journal Name
Tikrit Journal Of Engineering Sciences
Curvature Ductility of Reinforced Concrete Column Sections Under Different strain Rates
...Show More Authors

This paper presents theoretical parametric study of the curvature ductility capacity for reinforced concrete column sections. The study considers the behavior of concrete and reinforcing steel under different strain rates. A computer program has been written to compute the curvature ductility taking into account the spalling in concrete cover. Strain rate sensitive constitutive models of steel and concrete were used for predicting the moment-curvature relationship of reinforced concrete columns at different rate of straining. The study parameters are the yield strength of main reinforcement, yield strength of transverse reinforcement, compressive strength of concrete, spacing of ties and the axial load. The results indicated that hi

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Sun Mar 01 2015
Journal Name
Journal Of Engineering
Retrofitting of Reinforced Concrete Damaged Short Column Exposed to High Temperature
...Show More Authors

Experimental research was carried out to investigate the performance of CFRP wrapping jackets used for retrofitting twelve square reinforced concrete (CR) column specimens damaged by exposure to fire flame, at different temperatures of  300, 500 and 700ºC, except for two specimens that were not burned. The specimens were then loaded axially till failure after gradual or sudden cooling. The specimens were divided into two groups containing two main reinforcement ratios, ρ= 0.0314 and ρ= 0.0542. This was followed by the retrofitting procedure that included wrapping all the specimens with two layers of CFRP fabric sheets. The test results of the retrofitted specimens showed that the fire damaged RC

... Show More
View Publication Preview PDF