Preferred Language
Articles
/
Yhfm4o4BVTCNdQwCtVmK
Experimental and Numerical Study of Open Channel Flow with T-Section Artificial Bed Roughness
...Show More Authors

Experimental and numerical studies have been conducted on the effects of bed roughness elements such as cubic and T-section elements that are regularly half-channel arrayed on one side of the river on turbulent flow characteristics and bed erosion downstream of the roughness elements. The experimental study has been done for two types of bed roughness elements (cubic and T-section shape) to study the effect of these elements on the velocity profile downstream the elements with respect to different water flow discharges and water depths. A comparison between the cubic and T-section artificial bed roughness showed that the velocity profile downstream the T-section increased in smooth side from the river and decrease in the rough side from it compared with the case when a cubic artificial bed roughness is used. By comparing the results for the element shapes, it can be notices that the T-section bed roughness element more effective compared to cubic shape for both sides of the channel. The numerical method has been done using Computational Fluid Dynamic (CFD) method. A validation for the CFD model with the experimental study have been carried out for a specific flow discharge and water depth. The results indicated that the velocity distribution profiles downstream the bed roughness elements in both sides shown very good agreement for manning coefficients between the numerical and experimental studies. The range of errors between the experimental and numerical study have been calculated using Root Mean Square Error (RMSE) approach, which is found that the RMSE is approximately equal to 1 in case of cubic bed roughness and the RMSE is about 1.5 in case of T-section bed roughness for both smooth and rough sides. Furthermore, the influence of the velocity profile and the bed erosion downstream of the T-section element under the effect of tides have been investigated using the CFD method, which is commonly happened in Shat al-Arab south of Iraq. The results show that the tide of the flow has a reverse effect on the velocity profiles for both sides. Since the velocity profile downstream of bed roughness region increase in the rough side and decrease in the smooth side compared with the normal flow of the river.

Scopus Crossref
View Publication
Publication Date
Mon May 01 2023
Journal Name
Materials Today: Proceedings
An experimental study of the effects of matrix acidising on the petrophysical characteristics of carbonate formation
...Show More Authors

View Publication
Scopus (6)
Crossref (2)
Scopus Crossref
Publication Date
Wed Mar 11 2020
Journal Name
Journal Of Cardiovascular Disease Research
Resistive Index is an Early Indicator for Flow Deterioration in Comparison with Intima Media Thickness for Patients with Hypertension and Diabetes in Relation to Age
...Show More Authors

Background: Atherosclerosis is well known related to age and certain cardiovascular diseases. Aging is one reason of arteries function deterioration which can cause loss of compliance and plaque accumulation, this effect increases by the presence of certain diseases such as hypertension and diabetes disease. Aim: To investigate the reduction of blood supply to the brain in patients with diabetes and hypertension with age and the role of resistive index in the diagnosis of reduced blood flow. Method: Patients with both diseases diabetic and hypertension were classified according to their age to identify the progression of the disease and factors influencing the carotid artery blood flow. By using ultrasound and standard Doppler techniq

... Show More
View Publication
Scopus (3)
Crossref (1)
Scopus Crossref
Publication Date
Wed Aug 17 2022
Journal Name
Sustainability
Experimental Evaluation of the Thermoelectrical Performance of Photovoltaic-Thermal Systems with a Water-Cooled Heat Sink
...Show More Authors

A design for a photovoltaic-thermal (PVT) assembly with a water-cooled heat sink was planned, constructed, and experimentally evaluated in the climatic conditions of the southern region of Iraq during the summertime. The water-cooled heat sink was applied to thermally manage the PV cells, in order to boost the electrical output of the PVT system. A set of temperature sensors was installed to monitor the water intake, exit, and cell temperatures. The climatic parameters including the wind velocity, atmospheric pressure, and solar irradiation were also monitored on a daily basis. The effects of solar irradiation on the average PV temperature, electrical power, and overall electrical-thermal efficiency were investigated. The findings i

... Show More
View Publication
Scopus (41)
Crossref (36)
Scopus Clarivate Crossref
Publication Date
Fri Jan 01 2021
Journal Name
Journal Of Engineering
Roughness Effect on Thermo-Elasto-Hydrodynamic Performance of a 170ᵒ -Arc Partial Journal Bearing
...Show More Authors

In the current analysis, the effects of circumferential scratches along the inner surface of a 170ᵒ -arc partial journal bearing has been numerically investigated. Their impact on the thermo-elasto-hydrodynamic performance characteristics, including maximum pressure, temperature, deformation, and stress, has been examined thoroughly. The ANSYS Fluent CFD commercial code was employed to tackle the iterative solution of flow and heat transfer patterns in the fluid film domain. They are then applied to the ANSYS Static Structure solver to compute the deformation and stress resulted in the solid bearing zone. A wide range of operating conditions has been considered, including the eccentricity ratio ( ) and scratch depth (

... Show More
View Publication Preview PDF
Crossref (6)
Crossref
Publication Date
Tue Dec 01 2020
Journal Name
Journal Of Engineering
Development of Regression Models for Predicting Pavement Condition Index from the International Roughness Index
...Show More Authors

Flexible pavements are considered an essential element of transportation infrastructure. So, evaluations of flexible pavement performance are necessary for the proper management of transportation infrastructure. Pavement condition index (PCI) and international roughness index (IRI) are common indices applied to evaluate pavement surface conditions. However, the pavement condition surveys to calculate PCI are costly and time-consuming as compared to IRI. This article focuses on developing regression models that predict PCI from IRI. Eighty-three flexible pavement sections, with section length equal to 250 m, were selected in Al-Diwaniyah, Iraq, to develop PCI-IRI relationships. In terms of the quantity and severity of eac

... Show More
View Publication Preview PDF
Crossref (8)
Crossref
Publication Date
Tue Jan 01 2019
Journal Name
Energy Procedia
Calculating Surface Roughness for a Large Scale SEM Images by Mean of Image Processing
...Show More Authors

View Publication
Scopus (30)
Crossref (32)
Scopus Clarivate Crossref
Publication Date
Sat Mar 10 2012
Journal Name
الدنانير
Cryptography Using Artificial Neural Network
...Show More Authors

Neural cryptography deals with the problem of “key exchange” between two neural networks by using the mutual learning concept. The two networks exchange their outputs (in bits) and the key between two communicating parties ar eventually represented in the final learned weights, when the two networks are said to be synchronized. Security of neural synchronization is put at risk if an attacker is capable of synchronizing with any of the two parties during the training process.

Preview PDF
Publication Date
Thu Feb 01 2024
Journal Name
Journal Of Engineering
Performance Evaluation of Two Stages Parallel Flow Indirect Evaporative Cooling with Aspen Pads in Baghdad Climate Conditions
...Show More Authors

This study delves into the realm of advanced cooling techniques by examining the performance of a two-stage parallel flow indirect evaporative cooling system enhanced with aspen pads in the challenging climate of Baghdad. The objective was to achieve average air dry bulb temperatures (43 oC) below the ambient wet bulb temperatures (24.95 oC) with an average relative humidity of 23%, aiming for unparalleled cooling efficiency. The research experiment was carried out in the urban environment of Baghdad, characterized by high temperature conditions. The investigation focused on the potential of the two-stage parallel flow setup, combined with the cooling capability of aspen pads, to surpass the limitat

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu May 18 2023
Journal Name
Journal Of Engineering
Experimental Study of Power Increase Transient in Heat Generation Systems Simulated By Immersed Heat Source
...Show More Authors

Theoretical and experimental investigations of the transient heat transfer parameters of constant heat flux source subjected to water flowing in the downward direction in closed channel are conducted. The power increase transient is ensured by step change increase in the heat source power. The theoretical investigation involved a mathematical modeling for axially symmetric, simultaneously developing laminar water flow in a vertical annulus. The mathematical model is based on one dimensional downward flow. The boundary conditions of the studied case are based on adiabatic outer wall, while the inner wall is subjected to a constant heat flux. The heat & mass balance equation derived for specified element of bulk water within the annulu

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Sep 02 2022
Journal Name
Frontiers In Built Environment
Thermal analysis of horizontal earth-air heat exchangers in a subtropical climate: An experimental study
...Show More Authors

The earth-air heat exchanger (EHX) has a promising potential to passively save the energy consumption of traditional air conditioning systems while maintaining a high degree of indoor comfort. The use of EHX systems for air conditioning in commercial and industrial settings offers several environmental benefits and is capable of operating in both standalone and hybrid modes. This study tests the performance and effectiveness of an EHX design in a sandy soil area in Baghdad, Iraq. The area has a climate of the subtropical semi-humid type. Ambient air temperatures and soil temperatures were recorded throughout the months of 2021. During the months of January and June, the temperatures of the inlet and outflow air at varying air veloci

... Show More
View Publication
Scopus (16)
Crossref (13)
Scopus Clarivate Crossref