Enhancement of heat transfer in the tube heat exchanger is studied experimentally by using discrete twisted tapes. Three different positions were selected for inserting turbulators along tube section (horizontal position by α= 00, inclined position by α= 45 0 and vertical position by α= 900). The space between turbulators was fixed by distributing 5 pieces of these turbulators with pitch ratio PR = (0.44). Also, the factor of constant heat flux was applied as a boundary condition around the tube test section for all experiments of this investigation, while the flow rates were selected as a variable factor (Reynolds number values vary from 5000 to 15000). The results s
... Show MoreIn this paper a system is designed and implemented using a Field Programmable Gate Array (FPGA) to move objects from a pick up location to a delivery location. This transportation of objects is done via a vehicle equipped with a robot arm and an FPGA. The path between the two locations is followed by recognizing a black line between them. The black line is sensed by Infrared sensors (IR) located on the front and on the back of the vehicle. The Robot was successfully implemented by programming the Field Programmable Gate Array with the designed system that was described as a state diagram and the robot operated properly.
Abstract: When it comes to applications in welding, cutting, and surface engineering, the utilization of high-power fiber-delivered beams from solid-state lasers offers several benefits. This paper addresses the issue of cleaning the surface of the samples with different spot sizes (50, 100 and 200) (industrial ytterbium fiber laser) to prepared it to be welded. Angular laser cleaning with incident angles (5, 10, 15, 20, 25, 30) ° with different powers (3, 5, 7, 10) W and hatch distance 0.001 was use for implemented.
The properties of capturing of peristaltic flow to a chemically reacting couple stress fluid through an inclined asymmetric channel with variable viscosity and various boundaries are investigated. we have addressed the impacts of variable viscosity, different wave forms, porous medium, heat and mass transfer for peristaltic transport of hydro magnetic couple stress liquid in inclined asymmetric channel with different boundaries. Moreover, The Fluid viscosity assumed to vary as an exponential function of temperature. Effects of almost flow parameters are studied analytically and computed. An rising in the temperature and concentration profiles return to heat and mass transfer Biot numbers. Noteworthy, the Soret and Dufour number effect resul
... Show MoreExperimental study of heat transfer coefficients in air-liquid-solid fluidized beds were carried out by measuring the heat rate and the overall temperature differences across the heater at different operating conditions. The experiments were carried out in Q.V.F. glass column of 0.22 m inside diameter and 2.25 m height with an axially mounted cylindrical heater of 0.0367 m diameter and 0.5 m height. The fluidizing media were water as a continuous phase and air as a dispersed phase. Low density (Ploymethyl-methacrylate, 3.17 mm size) and high density (Glass beads, 2.31 mm size) particles were used as solid phase. The bed temperature profiles were measured axially and radially in the bed for different positions. Thermocouples were connecte
... Show MoreBackground: Infection with Toxoplasma gondii (T. gondii) leads to activation of T-helper cells (Th-1 and Th-2) which are involved in the synthesis and release of different cytokines which may lead to endothelial dysfunction. Objectives: To evaluate the endothelial function in patients with acute toxoplasmosis. Methods: This case-control study involved 31 patients with toxoplasmosis aged 19 - 47 years matched with 20 healthy subjects. Anti-T. gondii antibody (IgG, IgM, IgA) was determined by direct antigen-antibody reaction. Interleukin-6(IL-6), endothelin-1 (ET-1) and human malondialdehyde (MDA) serum levels were measured. Results: IgM, IgG and IgA levels were high in the infected patients compared with controls (P < 0.01). Furthermore, IL-
... Show MoreRheumatoid arthritis is an inflammatory chronic disease with an autoimmune pathogenesis. To determine the role of Helicobacter pylori as a trigger agent, twenty five patients with rheumatoid arthritis of ages (15-47) years have been investigated and compared with twenty healthy individuals. All the studied groups were carried out to measure the rheumatoid arthritis (RA) IgM, anti-CCP antibody IgG and IgA by ELISA test and by measured anti-IgG antibody level of H. pylori by using ELISA and IFAT techniques. The present study showed significant differences (P< 0.05) of anti-H. Pylori in sera of RA patients than control group, this lead to suggest that H. pylori had a role in pathogenesis of RA.
This study accomplished to determine levels of salivary Alpha-Amylase (sAA) in Iraqi children with positive family history of hypertension, Hypertension was believed to be a risk factor in 18% of all deaths in 2010 (9.4 million globally). This study included one hundred children from primary school aged 6 to 13 years, with a focus in child welfare and family health history, with an emphasis on close relatives' hypertension reputations, with hypertension close relatives record categories identified by 1st and 2nd relatives, after documenting the full details, the burden was assessed for the children's families. The influence of age is confirmed by a correlation study of our own numbers, which shows a positive correlation. The disparity betwe
... Show More