The measurement of vitamin B1 in pure and pharmaceutical formulations was proposed by using a straightforward and sensitive spectrophotometric approach. Sulfacetamide (SFA) is diazotized, then coupled with vitamin B1 in alkaline media to produce a colored azo dye complex with a stability constant of 5.597 × 105 L/mol. The product is stable, with a maximum absorption wavelength of 489.5 nm, molar absorptivity of 10108 L/mol∙cm, Sandell's sensitivity of 0.0334 μg/cm2, detection limit of 0.0135 μg/mL, and Beer's law being observed over the concentration range of 0.2–20.0 μg/mL. The stability constant and stoichiometry of the produced azo dye were calculated using the continuous variation (Job's) and mole ratio methods. The suggested ap
... Show MoreObjective(s): To assess the burden of mothers` care for child with colostomy and find out relationships between child and mother socio-demographic data with mothers` burden. Methodology: a descriptive study was conducted from 1 August 2013 to 1 September 2014. The sample consisted of 100 children and their mothers at Baghdad Teaching hospital in Baghdad city. A questionnaire was prepared based on the previous literature review, meeting mothers of children with colostomy, and the Zarit Burden Interview scale. Data has collected through the application of questionnaire and interview techniques. Results: T
This paper discussed the solution of an equivalent circuit of solar cell, where a single diode model is presented. The nonlinear equation of this model has suggested and analyzed an iterative algorithm, which work well for this equation with a suitable initial value for the iterative. The convergence of the proposed method is discussed. It is established that the algorithm has convergence of order six. The proposed algorithm is achieved with a various values of load resistance. Equation by means of equivalent circuit of a solar cell so all the determinations is achieved using Matlab in ambient temperature. The obtained results of this new method are given and the absolute errors is demonstrated.
Objective: To determine the effectiveness of hypothermia on renal functions for patients undergoing
coronary artery bypass graft CABG surgery.
Methodology: A purposive (non-probability) sample of (50) patients undergoing Isolated coronary artery
bypass graft surgery consecutively admitted to the surgical ward, and they were followed up in the
intraoperative, Intensive Care Unit (ICU) and in the postoperative (surgical ward). Post-operative renal function
test (glumeruler filteration rate (GFR) by using the Crockroft-Gault formula and serum creatinine level) was
determined first week post operative and post operative renal function was classified on the base of peak of
the serum creatinine level and decline of glomeru
The region-based association analysis has been proposed to capture the collective behavior of sets of variants by testing the association of each set instead of individual variants with the disease. Such an analysis typically involves a list of unphased multiple-locus genotypes with potentially sparse frequencies in cases and controls. To tackle the problem of the sparse distribution, a two-stage approach was proposed in literature: In the first stage, haplotypes are computationally inferred from genotypes, followed by a haplotype coclassification. In the second stage, the association analysis is performed on the inferred haplotype groups. If a haplotype is unevenly distributed between the case and control samples, this haplotype is labeled
... Show MoreThis work presents the construction of a test apparatus for air-conditioning application that is flexible in changing a scaled down adsorbent bed modules. To improve the heat and mass transfer performance of the adsorbent bed, a finned-tube of the adsorbent bed heat exchanger was used. The results show that the specific cooling power (SCP) and the coefficient of performance (COP) are 163 W/kg and 0.16, respectively, when the cycle time is 40 min, the hot water temperature is 90oC, the cooling water temperature is 30oC and the evaporative water temperature is 11.4oC.