Preferred Language
Articles
/
YWE4RZkBdMdGkNqj-iX9
Hypothesis Testing for Non-Normal Multiple Compact Regression Model
...Show More Authors

Generalized multivariate transmuted Bessel distribution belongs to the family of probability distributions with a symmetric heavy tail. It is considered a mixed continuous probability distribution. It is the result of mixing the multivariate Gaussian mixture distribution with the generalized inverse normal distribution. On this basis, the paper will study a multiple compact regression model when the random error follows a generalized multivariate transmuted Bessel distribution. Assuming that the shape parameters are known, the parameters of the multiple compact regression model will be estimated using the maximum likelihood method and Bayesian approach depending on non-informative prior information. In addition, the Bayes factor was used as a criterion to test the hypotheses. A Gaussian distribution rule selects the bandwidth parameter and the kernel function based on the Gauss kernel function and quartic kernel function. It estimates the model parameters are under quadratic loss function. The researchers concluded that the posterior probability distribution of is a multivariate t distribution. Applying the findings to real data related to the jaundice percentage in the blood component as a response variable, red blood cell volume and red blood cell sedimentation as parametric influencing variables, and white and red cells as nonparametric influencing variables, the researchers concluded that when the shape parameters increase, the values ​​of the mean square error criteria of And the variance parameter decreases.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sat Oct 01 2022
Journal Name
Medical Journal Of Babylon
Plasma Sclerostin Level in Multiple Myeloma
...Show More Authors
Background:

Multiple myeloma (MM) is a heterogenous plasma cell malignancy with various complications. Sclerostin is a Wingless-type (Wnt) inhibitor specifically expressed by osteocytes; it acts as a negative regulator of bone formation.

Objectives:

To assess plasma sclerostin level in MM patients and find its correlations with clinical and laboratory data, including osteolytic bone disease and international staging system (ISS).

Materials and Methods:

This cr

... Show More
View Publication Preview PDF
Scopus (2)
Crossref (1)
Scopus Crossref
Publication Date
Sat Oct 01 2022
Journal Name
Journal Of Pakistan Association Of Dermatologists
Zinc as an essential element for normal immune reactions and as a therapeutic agent for autoimmune diseases
...Show More Authors

Scopus (1)
Scopus
Publication Date
Fri Mar 21 2014
Journal Name
International Journal Of Antennas And Propagation
Development of a Compact Wide-Slot Antenna for Early Stage Breast Cancer Detection Featuring Circular Array Full-View Geometry
...Show More Authors

A novel planar type antenna printed on a high permittivity Rogers’ substrate is proposed for early stage microwave breast cancer detection. The design is based on a p-shaped wide-slot structure with microstrip feeding circuit to eliminate losses of transmission. The design parameters are optimized resulting in a good reflection coefficient at −10 dB from 4.5 to 10.9 GHz. Imaging result using inhomogeneous breast phantom indicates that the proposed antenna is capable of detecting a 5 mm size cancerous tumor embedded inside the fibroglandular region with dielectric contrast between the target and the surrounding materials ranging from 1.7 : 1 to 3.6 : 1.

Publication Date
Fri Nov 11 2011
Journal Name
Thesis
Performance Analysis of a New Compact Magneto-Rheological Proportional Control Valve for Hydraulic Actuation Using FEM and Experimental Approach
...Show More Authors

One of the main parts in hydraulic system is directional control valve, which is needed in order to operate hydraulic actuator. Practically, a conventional directional control valve has complex construction and moving parts, such as spool. Alternatively, a proposed Magneto-rheological (MR) directional control valve can offer a better solution without any moving parts by means of MR fluid. MR fluid consists of stable suspension of micro-sized magnetic particles dispersed in carrier medium like hydrocarbon oil. The main objectives of this present research are to design a MR directional control valve using MR fluid, to analyse its magnetic circuit using FEMM software, and to study and simulate the performance of this valve. In this research, a

... Show More
Publication Date
Sat Oct 01 2016
Journal Name
Journal Of Economics And Administrative Sciences
Bayesian Estimator for the Scale Parameter of the Normal Distribution Under Different Prior Distributions
...Show More Authors

In this study, we used Bayesian method to estimate scale parameter for the normal distribution. By considering three different prior distributions such as the square root inverted gamma (SRIG) distribution and the non-informative prior distribution and the natural conjugate family of priors. The Bayesian estimation based on squared error loss function, and compared it with the classical estimation methods to estimate the scale parameter for the normal distribution, such as the maximum likelihood estimation and th

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat Nov 01 2014
Journal Name
International Journal Of Statistics
Single and Double Stage Shrinkage Estimators for the Normal Mean with the Variance Cases
...Show More Authors

View Publication
Publication Date
Sat Jan 01 2011
Journal Name
Journal Of Engineering
TWO-PARAMETER GAMMA DISTRIBUTION AND LOG NORMAL DISTRIBUTION FOR DERIVATION OF SYNTHETIC UNIT HYDROGRAPH
...Show More Authors

Most available methods for unit hydrographs (SUH) derivation involve manual, subjective fitting of
a hydrograph through a few data points. The use of probability distributions for the derivation of synthetic
hydrographs had received much attention because of its similarity with unit hydrograph properties. In this
paper, the use of two flexible probability distributions is presented. For each distribution the unknown
parameters were derived in terms of the time to peak(tp), and the peak discharge(Qp). A simple Matlab
program is prepared for calculating these parameters and their validity was checked using comparison
with field data. Application to field data shows that the gamma and lognormal distributions had fit well.<

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Sun Apr 06 2008
Journal Name
Diyala Journal For Pure Science
Preliminary Test Bayesian –Shrunken Estimators for the Mean of Normal Distribution with Known Variance
...Show More Authors

Publication Date
Thu Aug 01 2019
Journal Name
Journal Of Economics And Administrative Sciences
The use of the Biz method and classical methods in estimating the parameters of the binary logistic regression model
...Show More Authors

Abstract

          Binary logistic regression model used in data classification and it is the strongest most flexible tool in study cases variable response binary when compared to linear regression. In this research, some classic methods were used to estimate parameters binary logistic regression model, included the maximum likelihood method, minimum chi-square method, weighted least squares, with bayes estimation , to choose the best method of estimation by default values to estimate parameters according two different models of general linear regression models ,and different s

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Sep 06 2015
Journal Name
Baghdad Science Journal
Single-input Multiple-output Signals Third-order Active-R Filter for different Circuit Merit Factor (Q)
...Show More Authors

Single-input Multiple-output Signals Third-order Active-R Filter for different Circuit Merit Factor Q Configuration is proposed. This paper discusses a new configuration to realize third-order low pass, band pass and high pass. The presented circuit uses Single-input Multiple-output signals, OP-AMP and passive components. This filter is useful for high frequency operation, monolithic IC implementation and it is easy to design .This circuit gives three filter functions low-pass, high-pass and band-pass. This filter circuit can be used for different merit factor (Q) with high pass band gain. This gives better stop-band attenuation and sharper cut-off at the edge of the pass-band. Thus the response shows wider pass-band. The Ideal value of thi

... Show More
View Publication Preview PDF
Crossref