Gypseous soils are common in several regions in the world including Iraq, where more than 28.6% of its surface is covered with this type of soil. This soil, with high gypsum content, causes different problems for construction and strategic projects. As a result of water flow through the soil mass, the permeability and chemical arrangement of these soils varies with time due to the solubility and leaching of gypsum. In this study, the soil of 36% gypsum content, was taken from one location about 100 km southwest of Baghdad, where the samples were taken from depths (0.5 - 1) m below the natural ground and mixed with (3%, 6%, 9%) of Copolymer and Novolac polymer to improve the engineering properties that include: collapsibility, permeability and compaction parameter. Results of experimental work showed noticeable improvement of collapsibility and permeability for the soil treated with polymer materials compared to untreated soil. Adding 3% of polymer (copolymer and novolac polymer) materials gave the best improvement in collapsibility which reached to (44.5 and 46%), respectively, in 3 hours. The improvement in permeability reached to 98.6% copolymer and 86.2% novolac polymer in 1 day.
Abandoned mines and mining activities are considered one of the most significant sources of trace metal contamination worldwide. Those activities resulted in environmental contamination of particular surrounding ecosystems of abandoned ecosystems. The main aim of this study is to evaluate the trace metal contamination in the vicinity of abandoned mine located in Leicestershire English Midland. Twelve soil samples with two water samples were collected from the abandoned mine site. Test results showed a wide range of soil pH was observed from extremely acid (2.5) to slightly alkaline (7.4) as well as LOI from 8% organic matter content to 40% was found. Moreover, results demonstrated that most elements were below Soil Guideline Values (SGV)
... Show MoreAbstract
This paper represents a study of the effect of the soil type, the drilling parameters and the drilling tool properties on the dynamic vibrational behavior of the drilling rig and its assessment in the drilling system. So first, an experimental drilling rig was designed and constructed to embrace the numerical work.
The experimental work included implementation of the drill-string in different types of soil with different properties according to the difference in the grains size, at different rotational speeds (RPM), and different weights on bit (WOB) (Thrust force), in a way that allows establishing the charts that correlate the vibration acceleration, the rate of penetration (ROP), and the power
... Show MoreThis study aims to evaluate the concentration of the heavy metals (Co, Cd, Cr, Cu, Ni, Pb, and Zn) and their ecological risk in soils adjacent to the power generators of Ramadi city, Iraq. The soil samples were collected from a depth of 20cm. The obtained results showed that the mean concentrations of heavy metals (HMs) are ranked as in the following order: Cr (360.90mg/kg) > Ni (283.65mg/kg) > Zn (190.96mg/kg) > Pb (130.75 mg/kg) > Cu (36.54 mg/kg) > Co (16.62 mg/kg) > Cd (2.55 mg/kg). The mean values of HMs concentration exceed the international guidelines. The result of correlation matrix analysis at P £ 0.05 showed significant correlations between the concentrations of HMs. These correlatio
... Show MoreThis paper presents the synthesis of a polypropylene nanocomposite. The nanocomposites were characterized using different techniques: atomic electron microscopy (AFM), surface shape was evaluated by (SEM),(EDS),(XRD) and (FTIR). The study showed that the platinum nanocomposite had a fatal effect on both strains of bacteria used, as well as on the growth of fungi. The compound tested showed antioxidant properties moderate activity was found. The mentioned material were evaluated in normal cell line HdFn (Human Dermal Fibroblasts, neonatal) and breast cancer MCF-7 cancer cell line , by MTT assay for study cytotoxic effects, morphological changes, all experiments were conducted on cell lines by using the
... Show MorePolymer composite materials were prepared by mixing epoxy resin with sand particles in three different grain size (150-300 ), (300-600 ) and (600- 1200) μm . The weight of epoxy was 15%, 20%, 25% and 30% of the total weight. Compression strength and flexural strength tests were carried out for the prepared samples .The percentages of epoxy resin at 20% wt and 25% wt showed best mechanical properties for all grain sizes .These percentages were adopted to fill the void between particles sand which have two different size ranges (150-600) μm and {(150-300) & (600-1200)} μm respectively to obtain more dense material. The results showed that the strength of polymer composite at 20% resin is higher than 25% resin. The
... Show MorePMMA films of different thickness (0.006, 0.0105, 0.0206, 0.0385 and 0.056cm) were synthesized by casting process. The temperature and frequency dependence of dielectric constant and AC electrical conductivity measurements at various frequencies (10kHz-10MHz) and temperatures (293-373K) were carried out. Few anomalies in dielectric studies were observed near 313 and 373 K respectively. These points were related to glass transitions temperature. The variation of activation energy and conduction behavior was studied .From the AC conduction studies, it is confirmed that the mechanism responsible for the conduction process is hopping of carriers. The variations of the dielectric constant and loss as function of frequency at different tempera
... Show MoreTheligand4-[5-(2-hydoxy-phenyl)- [1,3,4- thiadiazole-2- ylimino methyl]-1,5-dimethyl -2-phenyl-1,2-dihydro-pyrazol-3-one [HL1] is prepared and characterized. It is reacted with poly(vinyl chloride) (PVC) in THF to form the PVC-L compounds ,PVC-L interacted with ions of transition metals to form PVC-L-MII complexes .All prepared compounds are characterized by FTIR spectroscopy, u.v-visible spectroscopy, C.H.N.S. analysis and some of them by 1HNMR
The rheological behavior among factors that are present in Stokes law can be used to control the stability of the colloidal dispersion system. The felodipine lipid polymer hybrid nanocarriers (LPHNs) is an interesting colloidal dispersion system that is used for rheological characteristic analysis. The LPHNs compose of polymeric components and lipids. This research aims to prepare oral felodipine LPHNs to investigate the effect of independent variables on the rheological behavior of the nanosystem. The microwave-based technique was used to prepare felodipine LPHNs (H1-H9) successfully. All the formulations enter the characterization process for particle size and PDI to ascertain the colloidal properties of the prepared nanosystem t
... Show MoreIn the present work, polymeric composites were prepared for coating floors and swimming pools in dark colors. This was achieved through the use of a polymer coating solution added to fine cement with weight percentage (wt%) values of 5, 10, 15, 20, and 25 to obtain dark-colored (gray) composites. Mortar samples were prepared using the adhesion test. The contact angle and adhesion strength were studied for the prepared samples concerning the effect of changing the weight ratio of additive cement on water absorption. Also, the antibacterial activity was tested for the prepared coatings. The results showed that the contact angle increases with increasing the weight ratios of additive cement, which indicates that the
... Show MoreSilicon nanowire arrays (SiNWs) are created utilizing the metal-assisted chemical etching method with an Ag metal as a catalyst and different etching time of 15, 30, and 60 minutes using n-Si (100). Physical properties such as structural, surface morphology, and optical properties of the prepared SiNWs are studied. The diameter of prepared SiNWs ranged from 20 to 280 nm, and the reflectance in the visible part of the wavelength spectrum was less than 1% for all prepared samples. The obtained energy gap of prepared SiNWs was around 2 eV, which is higher than the energy gap of bulk silicon. X-ray diffraction (XRD) has diffraction peaks at 68.70o for all prepared samples. The heterojunction solar cell was fabricated based on the
... Show More