The performance of a vapor compression refrigeration system (VCRS)-based residential air conditioner operating in a high-ambient temperature (HAT) country was investigated using six zero-ODP (ozone depletion potential) refrigerants as replacements to R22. The non-flammable alternative refrigerants considered in the present research were R134a, R404A, R407C, R410A, R448A, and R507A. Using the basic conservation laws, the VCRS was modeled during steady-state operation and solved using engineering equation solver (EES) software. Coefficient of performance (COP), pressures and temperatures at compressor suction and discharge, Global Warming Potential (GWP), critical pressure and temperature, compressor pressure ratio, volumetric cooling capacity (VCC) specific cooling capacity (SCC), and refrigeration effect were utilized as assessment criteria for the alternative refrigerants considered. From these refrigerants, the highest values of suction pressure, discharge temperature, and condenser pressure were attained by R410A. In addition, the discharge temperatures for all refrigerants, except R134a, were all higher than their corresponding critical values, causing a quicker drop in the VCRS’s performance. As an alternative refrigerant, R407C showed the highest SCC of 141.0 kJ/kg followed directly by 139.2 and 138.0 kJ/kg for R410A and R448A, respectively. A reverse trend was found for VCC with respective values of 4722 and 3775 kJ/m3 for R410A and R448A. Lower volume flow rates and smaller-sized compressors are expected for higher VCC refrigerants. The same trend was found for the compressor’s specific work input and condenser’s specific heat transfer with values of (51.14, 46.82, and 45.38 kJ/kg) and (190.3, 187.8, and 183.4 kJ/kg) for R410A, R407C, and R448A, respectively. For applications in HAT countries, larger condenser’s specific heat transfer makes the refrigerant more applicable. Conversely, with respect to COP, refrigerant R134a with a value of 3.075 was the superior alternative followed by R448A and R407C with respective COPs of 3.042 and 3.011. Based on the overall assessment in terms of environmental obligation, COP, compressor input power, refrigerant flow rate required, and all the evaluations made in this research, refrigerant R448A was recommended as the most appropriate substitute to R22 which can effectively be used in residential air conditioners in a HAT country.
Background: Fixed orthodontic appliances impede the maintenance of oral hygiene and result in plaque accumulation leads to enamel demineralization caused by acids produced by bacteria. Studies on plaque control strategies in orthodontic populations are limited. This might be caused by difficulties in the quantitative evaluation of dental plaque because the teeth have various levels of bracket coverage, and different tooth sizes and malocclusions, making the traditional categorical indices complex. The present study aims to evaluate the effect of different hygiene protocols on plaque quantity on bands with different attachments. Materials and method: Twenty patients had four bands within the orthodontic appliance. Then randomly divided into
... Show MoreThe shortage in surface water quantities led to a shift in dependence on the groundwater as an alternative water source in southern parts of Iraq. The groundwater is decreasing in quantity and water quality is degrading due to different factors. Therefore, it is important to assess the groundwater quality of the Missan Governorate of the country by analyzing the physicochemical parameters and distinguishing the probable sources of contaminants in the area. The present study used water quality diagrams and statistical methods such as factor analysis and agglomerative cluster analysis to determine the sources of chemical ions in the forty-four groundwater samples collected from wells in the study area. In addition, the Water Quality Index (WQ
... Show MoreBackground: Periodontitis (PD) is well-known chronic disease affecting the periodontal ligament and alveolar bone, Osteoarthritis (OA) is a chronic joint disease with compound reasons characterized by synovial inflammation, subchondral bone remodeling, also the formation of osteophytes, that cause cartilage degradation. Chronic periodontitis and osteoarthritis are considered widely prevalent diseases and related to tissue destruction due to chronic inflammation in general health and oral health. The aim of this study is todetermine the association of chronic periodontitis and osteoarthritits in patients by analysing tumor necrosis factor alpha TNFα and high sensitive c-reactive protein (hsCRP) in the serum. Materials and Method: A tot
... Show MoreThis study was conducted at the Poultry Research Station of the Agricultural Research Department/Ministry of Agriculture in Abu Ghraib for the period from 25/2/2019 to 7/4/2019 (42 days) with the aim of using several levels of Spirulina (SP)
The first aim of this paper was to evaluate the push-out bond strength of the gutta-percha coating of Thermafil and GuttaCore and compare it with that of gutta-percha used to coat an experimental hydroxyapatite/polyethylene (HA/PE) obturator. The second aim was to assess the thickness of gutta-percha around the carriers of GuttaCore and HA/PE obturators using microcomputed tomography (
Abstract
The aim of the research is to demonstrate the role of uncertainty in adopting the general requirements for the strategic environmental assessment of service departments in Babil Governorate and the Environment Department. By focusing on a range of environmental problems, despite the efforts exerted to deal with the environme
... Show MoreThe ratio of draft tube to reactor diameters is of decisive importance for the operation behavior of air lift loop reactors. The influence of draft tube geometry was investigated with respect to oxygen mass transfer and mixing time. The diameter ratio was varied between 0.33 and 0.80. The measurements were performed in two loop reactors with liquid capacities of 11.775 and 26.49 liters using aqueous with solutions of different coalescence behavior. The results show that there is no single diameter ratio which would produce most favorable conditions for the two process parameters. With respect to the more important requirements of aerobic cultures, i.e high oxygen mass transfer and efficient mixing, a diameter ratio between 0.5 and 0.6 is
... Show More