The performance of a vapor compression refrigeration system (VCRS)-based residential air conditioner operating in a high-ambient temperature (HAT) country was investigated using six zero-ODP (ozone depletion potential) refrigerants as replacements to R22. The non-flammable alternative refrigerants considered in the present research were R134a, R404A, R407C, R410A, R448A, and R507A. Using the basic conservation laws, the VCRS was modeled during steady-state operation and solved using engineering equation solver (EES) software. Coefficient of performance (COP), pressures and temperatures at compressor suction and discharge, Global Warming Potential (GWP), critical pressure and temperature, compressor pressure ratio, volumetric cooling capacity (VCC) specific cooling capacity (SCC), and refrigeration effect were utilized as assessment criteria for the alternative refrigerants considered. From these refrigerants, the highest values of suction pressure, discharge temperature, and condenser pressure were attained by R410A. In addition, the discharge temperatures for all refrigerants, except R134a, were all higher than their corresponding critical values, causing a quicker drop in the VCRS’s performance. As an alternative refrigerant, R407C showed the highest SCC of 141.0 kJ/kg followed directly by 139.2 and 138.0 kJ/kg for R410A and R448A, respectively. A reverse trend was found for VCC with respective values of 4722 and 3775 kJ/m3 for R410A and R448A. Lower volume flow rates and smaller-sized compressors are expected for higher VCC refrigerants. The same trend was found for the compressor’s specific work input and condenser’s specific heat transfer with values of (51.14, 46.82, and 45.38 kJ/kg) and (190.3, 187.8, and 183.4 kJ/kg) for R410A, R407C, and R448A, respectively. For applications in HAT countries, larger condenser’s specific heat transfer makes the refrigerant more applicable. Conversely, with respect to COP, refrigerant R134a with a value of 3.075 was the superior alternative followed by R448A and R407C with respective COPs of 3.042 and 3.011. Based on the overall assessment in terms of environmental obligation, COP, compressor input power, refrigerant flow rate required, and all the evaluations made in this research, refrigerant R448A was recommended as the most appropriate substitute to R22 which can effectively be used in residential air conditioners in a HAT country.
The determination of critical micelle concentration of selected non-ionic surfactants (Tween 20,40 and 80) have been investigated using magnetic water(MW)as an aqueous medium.Conductometry technique is used to determine critical micelle concentration.The effect of alcohol addition and temperature variation at the range(293.15 -303.15K) are also pursued. It is concluded that the process of micellization is spontaneous and endothermic because of the observed free energy of micellization (ΔGom) , enthalpy change of micellization (ΔHom), and entropy change of micellization (ΔSom) for the system was also studied.The properties of the non-ionic surfactants were studied, both in absence and presence of
... Show MoreAbstract A descriptive study was conducted in Al-Bashir teaching hospital in Amman city from 15th May 2004 to 15th August 2004 , in order to "Assess the adult asthmatic patients’ quality of life (QOL). Objective: This study aimed at identifying the domains of (Environmental, Physical, Daily Living Activity, Drug and Medication, Psychological , and Social), Methodology : A Purposive (Non-Probability) sample of (100) adult asthmatic patients visited the emergency department and outpatient clinic of chest department in Al-bashir hospital .A Questionnaire was constructed for the purpose of the study, and compris
The study area is witnessing divergence where I am North wind North East wind as we find that the north wind is getting replicated as we move from the south, The reason can be attributed to the nature of the surface of the region, with at least repeat this wind the northern region to the presence of mountain ranges, while we find that energizes the surface in the center and south helped to increase repeat this wind gusts, It also finds that the North wind East prevail in the northern region and least replicated as we move from the north to the south and to the fact that North stations are within blowing this wind sites for the circles near the display of high pressure located centers to the north-east, north and distancing itself from pa
... Show MoreBackground: The evaluation of the chronological age is a practical method in crime investigation field that assists in identifying individuals to treat them as underage or adult. This study aimed to assess the stages of third molars mineralization in relation to chronological age of Iraqi individuals, determine the gender differences and arches (maxillary/mandibular) differences.
Materials and Methods: A total of 300 orthopantomograms of orthodontic patients were collected according to specific criteria and evaluated visually. The developmental stages of maxillary and mandibular third molars were determined according to Demirjian method. T
... Show MoreThe sustainable competitive advantage for organizations is one of the requirements for value creation, which centered on the possession of scarce resources that achieve maximum flows to invest in intellectual capital, if what has been interest in them, measured and employed the way properly and style, so I figured the need for new technologies to enable organizations to measure the intellectual and physical assets and to assess its performance accordingly, so it sheds search light on the measurement of the added value of existing knowledge using the standard value-added factor is the intellectual (value added intellectual coefficient) (VAIC) and to develop a set of assumptions about the extent of the difference between the sample
... Show More