The performance of a vapor compression refrigeration system (VCRS)-based residential air conditioner operating in a high-ambient temperature (HAT) country was investigated using six zero-ODP (ozone depletion potential) refrigerants as replacements to R22. The non-flammable alternative refrigerants considered in the present research were R134a, R404A, R407C, R410A, R448A, and R507A. Using the basic conservation laws, the VCRS was modeled during steady-state operation and solved using engineering equation solver (EES) software. Coefficient of performance (COP), pressures and temperatures at compressor suction and discharge, Global Warming Potential (GWP), critical pressure and temperature, compressor pressure ratio, volumetric cooling capacity (VCC) specific cooling capacity (SCC), and refrigeration effect were utilized as assessment criteria for the alternative refrigerants considered. From these refrigerants, the highest values of suction pressure, discharge temperature, and condenser pressure were attained by R410A. In addition, the discharge temperatures for all refrigerants, except R134a, were all higher than their corresponding critical values, causing a quicker drop in the VCRS’s performance. As an alternative refrigerant, R407C showed the highest SCC of 141.0 kJ/kg followed directly by 139.2 and 138.0 kJ/kg for R410A and R448A, respectively. A reverse trend was found for VCC with respective values of 4722 and 3775 kJ/m3 for R410A and R448A. Lower volume flow rates and smaller-sized compressors are expected for higher VCC refrigerants. The same trend was found for the compressor’s specific work input and condenser’s specific heat transfer with values of (51.14, 46.82, and 45.38 kJ/kg) and (190.3, 187.8, and 183.4 kJ/kg) for R410A, R407C, and R448A, respectively. For applications in HAT countries, larger condenser’s specific heat transfer makes the refrigerant more applicable. Conversely, with respect to COP, refrigerant R134a with a value of 3.075 was the superior alternative followed by R448A and R407C with respective COPs of 3.042 and 3.011. Based on the overall assessment in terms of environmental obligation, COP, compressor input power, refrigerant flow rate required, and all the evaluations made in this research, refrigerant R448A was recommended as the most appropriate substitute to R22 which can effectively be used in residential air conditioners in a HAT country.
This research studies the influence of water source on the compressive strength of high strength concrete. Four types of water source were adopted in both mixing and curing process these are river, tap, well and drainage water (all from Iraq-Diyala governorate). Chemical analysis was carried out for all types of the used water including (pH, total dissolved solids (TDS), Turbidity, chloride, total suspended solid (TSS), and sulfates). Depending on the chemical analysis results, it was found that for all adopted sources the chemical compositions was within the ASTM C 1602/C 1602M-04 limits and can be satisfactorily used in concrete mixtures. Mixture of high strength concrete for compressive strength of (60 MPa) was designed and checked using
... Show MoreABSTRACT
The study evaluated the effect of adding quercetin to some characteristics of the sperm of the ram. This study was conducted in the animal field, Department of Animal Production, College of Agricultural Engineering Science, University of Baghdad for the period 5/12/2021 to 20/2/2022. In this experiment, 3 rams were used at the age of 2-2.5 years and weighed 50-55 kg. The semen was collected early in the morning and once a week and the semen was pooled to remove the individual differences. The treatments were divided: quercetin-free control group, treatment T1 (3 µL/mL quercetin), T2 treatment (6 µL/mL quercetin), T3 treatment (9 µL/mL quercetin). The result of the study showed
... Show MoreThe current study sheds light on the measurement and estimation of the radioactivity of radionuclides (238U, 226Ra, 232Th, and 40k) in natural waters of different regions of Nineveh Governorate in Iraq.15 samples were collected from different sources of natural waters, where gamma-ray spectroscopy was used using NaI)TI) sodium iodide detector to determine the concentration of radioactivity in the samples. According to the results, the radioactivity concentration in the tested water sample were ranged from 0.36 ± 0.04-1.57 ± 0.09with an average value of 0.69 ± 0.06 Bq/l for 238U, and 2.9 ± 0.02-0.88 ± 0.03 with an average value of 0.65 ± 0.03 Bq/l for 226Ra Bq/l
... Show MoreABSTRACT Background: One of the challenges to use chlorhexidine is its effect on the amount of microleakage after restoration; however, use of the materials with antibacterial properties after tooth preparation and before restoration has been widespread. The objective of this, in-vitro, study was to evaluate the influence of consepsis (chlorhexidine gloconate disinfectant) application on microleakage in class II cavities restored with light cured composite using universal adhesive system; etch and rinse technique –self etch technique. Materials and Methods: Forty class II cavities were prepared on mesial and distal surfaces of 20 non-carious mandibular third molars. The cavities were divided into four groups; (n =10 for each group).
... Show MoreThis paper aims to study the effect of circular Y-shaped fin arrangement to improve the low thermal response rates of a double-tube heat exchanger containing Paraffin phase change material (PCM). ANSYS software is employed to perform the computational fluid dynamic (CFD) simulations of the heat exchanger, including fluid flow, heat transfer, and the phase change process. The optimum state of the fin configuration is derived through sensitivity analysis by evaluating the geometrical parameters of the Y-shaped fin. For the same height of the fins (10 mm), the solidification time is reduced by almost 22%, and the discharging rate is enhanced by almost 26% using Y-shaped fins compared with the straight fins. The results demonstrate that the sol
... Show MoreThis in vitro study evaluated the influence of chemomechanical caries removal solution on the surface topography of metal-ceramic feldspar porcelain (MAJOR ceramic) and All-ceramic feldspar porcelain (Vita Alpha) using light polarizing microscope. Forty specimens of MAJOR ceramic and forty specimens of Vita Alpha ceramic of (12mm diameter & 3mm height) were prepared .All specimens were polished with silicon polishing burs, cleaned, autoglazed and stored in 37°C before exposure to Carisolv. Thirty specimens of each material randomly exposed to Carisolv gel for 5, 10 and 20 minutes respectively, other ten specimens were not, to act as control group. All specimens were subjected to surface roughness test by profilometer and evalua
... Show MoreObjective: This study evaluated the effect of immediate dentin sealing on the marginal adaptation of lithium disilicate overlays with three different types of resin-luting agents: preheated composite, dual-cure adhesive resin, and flowable composite. Materials and Methods: Forty-eight maxillary first premolars of similar size were prepared with a butt joint preparation design. The teeth were separated into two primary groups, each with twenty-four teeth: Group DDS: Delay dentin sealing (non-IDS) teeth were not treated. Group IDS: dentin sealing was applied immediately after teeth preparation. Each group was subsequently separated into three separate subgroups. Subgroups (DDS+Phc, IDS+Phc): cemented with preheated composite (Enamel plus HRi,
... Show More