In this research, an analysis for the standard Hueckel edge detection algorithm behaviour by using three dimensional representations for the edge goodness criterion is presents after applying it on a real high texture satellite image, where the edge goodness criterion is analysis statistically. The Hueckel edge detection algorithm showed a forward exponential relationship between the execution time with the used disk radius. Hueckel restrictions that mentioned in his papers are adopted in this research. A discussion for the resultant edge shape and malformation is presented, since this is the first practical study of applying Hueckel edge detection algorithm on a real high texture image containing ramp edges (satellite image).
A new method presented in this work to detect the existence of hidden
data as a secret message in images. This method must be applyied only on images which have the same visible properties (similar in perspective) where the human eyes cannot detect the difference between them.
This method is based on Image Quality Metrics (Structural Contents
Metric), which means the comparison between the original images and stego images, and determines the size ofthe hidden data. We applied the method to four different images, we detect by this method the hidden data and find exactly the same size of the hidden data.
There are many images you need to large Khoznah space With the continued evolution of storage technology for computers, there is a need nailed required to reduce Alkhoznip space for pictures and image compression in a good way, the conversion method Alamueja
In this paper a new fusion method is proposed to fuse multiple satellite images that are acquired through different electromagnetic spectrum ranges to produce a single gray scale image. The proposed method based on desecrate wavelet transform using pyramid and packet bases, the fusion process preformed using two different fusion rules, where the low frequency part is remapped through the use of PCA analysis basing on covariance matrix and correlation matrix, and the high frequency part is fused using different fusion rules (adding, selecting the higher, replacement), then the restored image is obtained by applying the inverse desecrate wavelet transform. The experimental results show the validity of the proposed fusion method to fuse suc
... Show More
Early detection of eye diseases can forestall visual deficiency and vision loss. There are several types of human eye diseases, for example, diabetic retinopathy, glaucoma, arteriosclerosis, and hypertension. Diabetic retinopathy (DR) which is brought about by diabetes causes the retinal vessels harmed and blood leakage in the retina. Retinal blood vessels have a huge job in the detection and treatment of different retinal diseases. Thus, retinal vasculature extraction is significant to help experts for the finding and treatment of systematic diseases. Accordingly, early detection and consequent treatment are fundamental for influenced patients to protect their vision. The aim of this paper is to detect blood vessels from
... Show MoreMeasurement of 238U, 233Th and 40K concentrations in soil samples collected from Ziggurat of Dur-Kurigalzu west region of Baghdad, have been evaluated, using high purity germanium detector. The activity concentrations of 238U, 233Th and 40K varied from 16.040 to 26.620 , 14.510 to 31.480 , and 153.820 to 266.320 with average values of 20.604±2.9 , 24.534±3.3 , 212.22±25.1 , respectively. The importance of these measurements lies in the estimation of radiation risk, radium equivalent, absorbed dose, annual effective dose, risk indices, gamma index, and cancer risk. The average value of the absorbed dose ranged from 33.187 outdoors to 63.111 indoo
... Show MoreThis research presents results on the full energy peak efficiency of a high purity germanium (HPGe) detector from point source as a function of photon energy and source-detector distance. The directions of photons emitted from the source and the photon path lengths in the detector were determined by Monte Carlo technique. A major advantage of this technique is the short computation time compared to the experiments. Another advantage is the flexibility for inputting detector-related parameters (such as source–detector distance, detector radius, length and attenuation coefficient) into the algorithm developed, thus making it an easy and flexible method to apply to other detector systems and configurations. It has been designed and writte
... Show MoreUranium concentrations in soil were determined for ten locations in Salahdin governorate using CR-39 track detector, fission fragments track technique was used, the nuclear reaction of nuclear fission fragments obtained by the bombardment of 235U with thermal neutrons from (Am-Be) neutron source with flux (5000n.cm-2.s-1), the concentration values were calculated by a comparison with standard samples. The results of the measurements show that the uranium concentration in soil samples various from 0.42±0.018ppm in Beji province to 0.2±0.014 ppm in Tooz province with an average (0.31±0.08ppm), the values of uranium concentration in all samples are within the permissible limits universally.
Radon is the air contaminant radioactive gas which people exposed to, is a reason for lung damages and lung cancer. The areas that are subject to high radon levels are found by radon concentration measurement. The radon activity concentration, annual effective dose, and potential alpha energy concentration (PAEC), were measured in houses of Ainkawa region using CR-39 solid state nuclear track detectors SSNTDs with the sealed-can technique. In the present paper the estimated values for radon activity concentration are in the range 55.99-112.8 Bq/m3 with 84.30 Bq/m3 as a mean value, the range of annual effective dose are 1.411-2.872 mSv/y, with mean value 2.124 mSv/y, and the potential alpha energy c
... Show MoreThe research aims to evaluate the radioactivity in elected samples of cereals and legume which are wide human consumption in Iraq using Nuclear Track Detectors (NTDs) model CN-85.
The samples were prepared scientifically according to references in this field. After 150 days of exposure, the detector were collected and chemically treated according to scientific sources (etching chemical), nuclear effects have been calculated using the optical microscope.
Radon (222Rn) concentration and uranium (238U) were calculated in unit Bq/m3 and (ppm), the results indicate that the highest concentration of radon and uranium was in yellow corn where the concentration of radon was 137.17×102 Bq/m3 and uranium concentration 2.63 (ppm). The lowest
For several applications, it is very important to have an edge detection technique matching human visual contour perception and less sensitive to noise. The edge detection algorithm describes in this paper based on the results obtained by Maximum a posteriori (MAP) and Maximum Entropy (ME) deblurring algorithms. The technique makes a trade-off between sharpening and smoothing the noisy image. One of the advantages of the described algorithm is less sensitive to noise than that given by Marr and Geuen techniques that considered to be the best edge detection algorithms in terms of matching human visual contour perception.